Specifications; Precautions - Mr. Heater MRHNF299810 Operating Instructions And Owner's Manual

Unvented lp-gas fired room heater
Table of Contents

Advertisement

SPECIFICATIONS

MODEL
BTU (Available)
Type of Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (Maximum)
Inlet Gas Pressure (Minimum)
Burners / Orifice nozzles
Thermostatic Control
Top
Sides
Floor (min. to top of carpet)
Fabric / flammable objects
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**

PRECAUTIONS:

1. 10,000 BTU may be installed in a bedroom, but shall
not be installed in a bathroom or any place where a
strong wind would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS) safety
shutoff system shuts down the heater if not enough
fresh air is available. See Fresh Air for Combustion
and Ventilation, page 4.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and let cool before servicing. Only a qualified
service person should service and repair heater.
6. Do not run heater:
• Where flammable liquids or vapors are used or stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder
residue within burner box or on adjacent walls or
furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to
inspect the room heater and to replace any part of
the control system and any gas control which has
been underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10.Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of
carbon monoxide may result if control knob is left
between locked positions.
Unvented Liquid Propane Fired Room Heater
MHVFRD10LP
4,500(Low) - 10,000 (High)
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
2
No
Clearances: inches (mm)
36" (915cm)
10" (254cm)
3" (76cm)
36" (915cm)
DANGER: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble
the flu, with headaches, dizziness, or nausea. If you
have these signs, the heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, persons
with heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all
warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
Product Features
3
Installation Instructions and Owner's Manual
MHVFBF10LP
4,500(Low) -10,000 (High)
LP-Gas Only
Piezo
10 Inches of Water
14 Inches of Water
11 Inches of Water
1
No
36" (915cm)
10" (254cm)
3" (76cm)
36" (915cm) 36" (915cm)
Burners
Grill
Front Panel
Figure 1
Control Knob
Heater
Cabinet