Download Print this page

Sealey G2201.V2 Manual page 2

Generator 2200w 230v 6.5hp

Advertisement

DO NOT over-fill fuel tank. Always leave room for fuel to expand.
8
DO NOT operate in the rain.
8
DANGER! DO NOT tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltage only when
running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads.
Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.
DO NOT operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT store generator with fuel in tank where petrol vapours might reach an open flame or spark.
8
2. INTRODUCTION
Heavy-duty frame design provides full protection and portability. Suitable for running power tools and lighting units. Long running with up
to 13 hours on a full tank. Fitted with two 230V 13A sockets. Powerful and reliable generator. Smooth running unit fitted with anti-vibration
engine mounts. Features low oil warning light, overload protection and fuel gauge.
3. SPECIFICATION
Model no: ............................................................... G2201.V2
Continuous Power Rating:...........................................2000W
Current Rating: ................................................................8.7A
Dimensions (W x D x H): .........................595 x 435 x 435mm
Fuel Tank: ........................................................................ 15L
Maximum Power Rating: .............................................2200W
Maximum Running Time: .................................................13hr
Motor Power: ...................................................... 4.9kW/6.5hp
Motor Type: .................................................... 4-Stroke Petrol
Noise Rating: ............................................................ 94dB(A)
Output: ................................................................ 230V~50Hz
2
© Jack Sealey Limited
Original Language Version
1 Tank indicator
2 Tank cover
3 2 x 230 V~ socket-outlets
4 Earth connection
5 Safety tripping element
6 Voltmeter
7 Oil filler plug
8 Oil drain plug
9 Oil shortage cut-out switch
9A Oil shortage alarm light
10 On/Off switch
11 Choke lever (diagram 2)
12 Recoil starter (diagram 2)
13 Petrol tap (diagram 2)
G2201.V2 Issue1
21/12/22

Advertisement

loading