Page 2
In no event shall ASRock Rack, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of...
Page 3
INTEL END USER SOFTWARE LICENSE AGREEMENT IMPORTANT - READ BEFORE COPYING, INSTALLING OR USING. LICENSE. Licensee has a license under Intel’s copyrights to reproduce Intel’s Software only in its unmodified and binary form, (with the accompanying documentation, the “Software”) for Licensee’s personal use only, and not commercial use, in connection with Intel-based products for which the Software has been provided, subject to the following conditions: (a) Licensee may not disclose, distribute or transfer any part of the Software, and You agree...
Page 4
defined in 48 C.F.R. 2.101) consisting of commercial computer software and commercial computer software documentation (as those terms are used in 48 C.F.R. 12.212), consistent with 48 C.F.R. 12.212 and 48 C.F.R 227.7202-1 through 227.7202-4. You will not provide the Software to the U.S. Government. Contractor or Manufacturer is Intel Corporation, 2200 Mission College Blvd., Santa Clara, CA 95054.
Page 5
ASRock Rack follows the green design concept to design and manufacture our products, and makes sure that each stage of the product life cycle of ASRock Rack product is in line with global environmental regulations. In addition, ASRock Rack disclose the relevant in- formation based on regulation requirements.
Contents Chapter 1 Introduction Package Contents Specifications Unique Features Motherboard Layout Onboard LED Indicators I/O Panel Block Diagram Chapter 2 Installation Screw Holes Pre-installation Precautions Installing the CPU and Heatsink Installation of Memory Modules (DIMM) 2.4.1 DIMM Population for DDR5 Expansion Slots (PCI Express Slots) Jumper Setup Onboard Headers and Connectors...
Page 7
Introduction 3.1.1 UEFI Menu Bar 3.1.2 Navigation Keys Main Screen 3.2.1 Motherboard Information 3.2.2 Processor Information 3.2.3 Memory Information Advanced Screen 3.3.1 CPU Configuration 3.3.2 Platform Power Configuration 3.3.3 DRAM Configuration 3.3.4 Chipset Configuration 3.3.5 Storage Configuration 3.3.6 NVMe Configuration 3.3.7 ACPI Configuration 3.3.8 USB Configuration 3.3.9 Super IO Configuration...
Page 8
3.3.17 Tls Auth Configuration 3.3.18 Instant Flash Server Mgmt 3.4.1 BMC Network Configuration 3.4.2 System Event Log 3.4.3 BMC Tools Security 3.5.1 Key Management Event Logs Boot Screen Exit Screen Chapter 4 Software Support Download and Install Operating System Download and Install Software Drivers Contact Information Chapter 5 Troubleshooting Troubleshooting Procedures...
In case any modifications of this manual occur, the updated version will be available on ASRock Rack website without further notice. Find the latest memory and CPU support lists on ASRock Rack website as well. ASRock Rack’s Website: www.ASRockRack.com About technical supporting for this motherboard, please refer to the website for future information.
1.2 Specifications SPC741D8-2L2T/BCM, SPC741D8-2T/BCM Physical Status Form Factor Dimension 12” x 10.5” (304.8 x 266.7 mm) Processor System Supports 4 Gen Intel® Xeon® Scalable Processors (codenamed Sapphire Rapids) Socket Single Socket E (LGA 4677) Thermal Design ~350W Power (TDP) Chipset Emmitsburg chipset Intel®...
Page 11
AMI 256Mb SPI Flash ROM Features Plug and Play (PnP), ACPI 4.0 and above compliance wake up events, SMBIOS 3.4 and above , ASRock Rack Instant Flash Internal Connectors/Headers PSU Connector 1 Micro-Fit (4-pin, ATX PSU signal), 3 (8-pin, ATX 12V)
Page 12
System Panel Header 1 (9-pin): power switch, reset switch, system power LED, HDD activity LED NMI Button COM Header 1 (9-pin) Speaker Header 1 (4-pin) Fan Header 6 (6-pin) Thermal Sensor Header TPM Header 1 (13-pin, SPI) VROC Header SGPIO Header HSBP SMbus Header PMbus Header...
. With this utility, press the <F6> key during the POST or the <F2> key to enter into the BIOS setup menu to access ASRock Rack Instant Flash. Just launch this tool and save the new BIOS file to the USB flash drive, floppy disk or hard drive, then update the BIOS only in a few clicks without preparing an additional floppy diskette or other complicated flash utility.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 1.6 I/O Panel No. Description No. Description USB 3.2 Gen1 Ports (USB3_1_2) 10G LAN RJ-45 Port (LAN1)*** LAN RJ-45 Port (IPMI_LAN)* 10G LAN RJ-45 Port (LAN2)*** 1G LAN RJ-45 Port (LAN3)** VGA Port (VGA1) (SPC741D8-2L2T/BCM only) 1G LAN RJ-45 Port (LAN4)**...
Page 20
**There is an LED on both sides of the 1G LAN port. Please refer to the table below for the LAN port LED indications. ACT/LINK LED SPEED LED LAN Port 1G LAN Port LED Indications (SPC741D8-2L2T/BCM only) Activity / Link LED Speed LED Status Description...
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Chapter 2 Installation This is a CEB form factor (12” x 10.5”) motherboard. Before installing the motherboard, study the configuration of the chassis to ensure that the motherboard fits into it. Make sure to unplug the power cord before installing or removing the motherboard. Failure to do so may cause physical injuries and damages to motherboard components.
2.4 Installation of Memory Modules (DIMM) This motherboard provides eight 288-pin DDR5 (Double Data Rate 5) DIMM slots in two groups, and supports Eight Channel Memory Technology. 1. For Eight channel configuration, it always need to install identical (the same brand, speed, size and chip-type) DDR5 DIMM groups.
2.5 Expansion Slots (PCI Express Slots) There are 4 PCI Express slots on this motherboard. PCIE slot: PCIE1 (PCIE 5.0 x16 slot, from CPU0) is used for PCI Express x16 lane width cards. PCIE3 (PCIE 5.0 x16 slot, from CPU0) is used for PCI Express x16 lane width cards. PCIE5 (PCIE 5.0 x16 slot, from CPU0) is used for PCI Express x16 lane width cards.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2.6 Jumper Setup The illustration shows how jumpers are setup. When the jumper cap is placed on the pins, the jumper is “Short”. If no jumper cap is placed on the pins, the jumper is “Open”. The illustration shows a 3-pin jumper whose pin1 and pin2 are “Short” when a jumper cap is placed on these 2 pins.
Page 34
The illustration shows how jumpers are setup. When the jumper cap is placed on the pins, the jumper is “Short”. If no jumper cap is placed on the pins, the jumper is “Open”. Password Reset Jumper Open: Normal Mode (Default) (2-pin PASSWORD_ Short: Password Clear 2-pin Jumper...
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2.7 Onboard Headers and Connectors Onboard headers and connectors are NOT jumpers. Do NOT place jumper caps over these headers and connectors. Placing jumper caps over the headers and connectors will cause permanent damage to the motherboard. System Panel Header...
Page 36
Auxiliary Panel Header This header supports multiple (18-pin AUX_PANEL1) functions on the front panel, (see p.6, No. 31) including the front panel SMB, internet status indicator and chassis intrusion pin. A. System Fault LED (2-pin LOCATOR) This header is for the Fault LED on the system. B.
Page 37
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Backplane PCI Express This header is used for the hot Hot-Plug Connector plug feature of HDDs on the (5-pin CPU1_ HSBP1) backplane. P0_HP_ALERT_L (see p.6, No. 35) CPU_HP_SDA CPU_HP_SCL Thermal Sensor Header Please connect the thermal (3-pin TR1) sensor cable to either pin 1-2 (see p.6, No.
Page 38
Front LAN LED This 4-pin connector is used LAN4_LINK LED_PWR Connector for the front LAN status (FRONT_LED_LAN34) indicator. LAN3_LINK LED_PWR (see p.6, No. 33) BMC SMB Header The header is used for the SM (5-pin BMC_SMB_1) BUS devices. (see p.6, No. 45) BMC_SMB_PRESENT_1_N Power BMC_SMBCLK...
Page 39
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Chassis Speaker Header Please connect the chassis DUMMY SPEAKER (4-pin SPEAK1) speaker to this header. (see p.6, No. 37) DUMMY USB 3.2 Gen1 Header Besides two default USB 3.2 (19-pin USB3_3_4) Gen1 ports on the I/O panel, (see p.6, No. 23) there is one USB 3.2 Gen1...
Page 40
ATX12V3 connector on the motherboard for power supply and signal communication. SATA1 Serial ATA3 Connectors These two SATA3 connectors support SATA data cables for (SPC741D8-2T/BCM only) (SATA0)(Lower) internal storage devices with (SATA1)(Upper) up to 6.0Gb/s data transfer SATA0 (see p.6, No. 17)
Page 41
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Virtual RAID On CPU This connector supports Intel® Header Virtual RAID on CPU and VROC RAID KEY (4-pin RAID_1) NVME/AHCI RAID on CPU +3VSB (see p.6, No. 28) PCIE. With the introduction of the Intel VROC product, there are three modes of operation:...
2.8 ATX PSU Power Connections This motherboard support ATX power input. Please refer to the table below for the required connections between the motherboard and the power supply. ATX PSU DC-IN (via a 24pin-to-4pin Converter Cable) 12V 8pin 12V 8pin ATX 4pin The following diagram illustrates how to connect the bundled ATX 24pin-to-4pin converter cable.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2.9 Dr. Debug Dr. Debug is used to provide code information, which makes troubleshooting even easier. Please see the diagrams below for reading the Dr. Debug codes. Code Description 0x10 PEI_CORE_STARTED 0x11 PEI_CAR_CPU_INIT 0x15 PEI_CAR_NB_INIT 0x19 PEI_CAR_SB_INIT 0x31...
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2.10 Unit Identification purpose LED/Switch With the UID button, it can be able to locate the server that are working on from behind a rack of servers. Unit Identification When the UID button on the purpose LED/Switch front or rear panel is pressed,...
2.11 Dua LAN and Teaming Operation Guide Dual LAN with Teaming enabled on this motherboard allows two single connections to act as one single connection(s) for twice the transmission bandwidth, making data transmission more effective and improving the quality of transmission of distant images. Fault tolerance on the dual LAN network prevents network downtime by transferring the workload from a failed port to a working port.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2.12 M.2 SSD Module Installation Guide The M.2 Socket (M2_1/M2_2, Key M) supports either a M.2 SATA3.6.0 Gb/s module or a M.2 PCI Express moduel up to Gen3x4 (8Gb/s x4). Installing the M.2 SSD Module Step 1 Prepare a M.2 SSD module and the screw.
Page 54
Step 3 Move the standoff based on the module type and length. Skip Step 3 and 4 and go straight to Step 5 upon going to use the default nut. Otherwise, release the standoff by hand. Step 4 Peel off the yellow protective film on the nut to be used.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Chapter 3 UEFI Setup Utility 3.1 Introduction This section explains how to use the UEFI SETUP UTILITY to configure the system. The UEFI chip on the motherboard stores the UEFI SETUP UTILITY. Run the UEFI SETUP UTILITY when starting up the computer. Please press <F2> or <Del> during the Power- On-Self-Test (POST) to enter the UEFI SETUP UTILITY;...
3.1.2 Navigation Keys Please check the following table for the function description of each navigation key. Navigation Key(s) Function Description Moves cursor left or right to select Screens Moves cursor up or down to select items + / - To change option for the selected items <Tab>...
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.2 Main Screen Entering the UEFI SETUP UTILITY, the Main screen displays the system overview. The Main screen provides system overview information and allows user to set the system time and date.
3.2.1 Motherboard Information Press [Enter] to view the information of the motheboard. 3.2.2 Processor Information Press [Enter] to view the information of the processor.
3.3 Advanced Screen In this section, it allows user to configure and view the following items: CPU Configura- tion, Platform Power Configuration, DRAM Configuration, Chipset Configuration, Stor- age Configuration, NVMe Configuration, ACPI Configuration, USB Configuration, Super IO Configuration, Serial Port Console Redirection, H/W Monitor, Runtime Error Log- ging, Intel SPS Information, Network Stack Configuration, Intel VMD Technology, Driver Health, Tls Auth Configuration and Instant Flash.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.1 CPU Configuration Active Processor 1 Cores Select the number of cores to enable in each processor package. Intel Hyper Threading Technology Intel Hyper Threading Technology allows multiple threads to run on each core, so that the overall performance on threaded software is improved.
Page 62
SW Guard Extensions (SGX) Use this item to enable or disable Software Guard Extensions (SGX). DCU Streamer Prefetcher DCU streamer prefetcher is an L1 data cache prefetcher (MSR 1A4h [2]). Hardware Prefetcher Automatically prefetch data and code for the processor. Enable for better performance. Adjacent Cache Line Prefetch Automatically prefetch the subsequent cache line while retrieving the currently requested cache line.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.2 Platform Power Configuration Intel SpeedStep Technology Intel SpeedStep technology allows processors to switch between multiple frequencies and voltage points for better power saving and heat dissipation. CPU turbo ratio can be fixed when Intel SpeedStep Technology set Disabled and Intel Turbo Boost Technology set En- abled.
Page 64
HWP Native Mode is a pre-requisite for enabling Dynamic SST-PP. Activate SST-BF Select this item to enable or disable the SST-BF. HWP Native Mode is a pre-requisite for enabling SST-BF; HWP Native Mode with No Legacy is a pre-requisite for configuring SST-BF. Configure SST-BF Select this item to enable or disable the BIOS to configure SST-BF High Priority Cores so that SW does not have to configure.
Page 65
SPC741D8-2T/BCM SPC741D8-2L2T/BCM CPU Thermal Throttling Select this item to enable or disable Thermal Monitor. Power Performance Tuning This allows user to decides which controls EFB. OS Controls EPB: Specifies IA32_ENERGY_PERF_BIAS is used. BIOS Controls EPB: Specifies ENERGY_PERF_BIAS_CONFIG is used. PECI Controls EPB: Specifies PCS53 is used.
3.3.3 DRAM Configuration Enforce DDR Memory Frequency POR Enable to enforce POR restrictions for DDR frequency and voltage programming. DRAM Frequency If [Auto] is selected, the motherboard will detect the memory module(s) inserted and assign the appropriate frequency automatically. Volatile Memory Mode Select 1LM or 2LM mode for Volatile memory.
Page 67
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Mirror Mode Mirror Mode will set entire 1LM/2LM memory in system to be mirrored, consequently reducing the memory capacity by half. Mirror Enable will disable XPT Prefetch. ADDDC Sparing Enable or disable Memory Rank Sparing. Patrol Scrub Patrol Scrub is a background activity initiated by the processor to seek out and fix memory errors.
3.3.4 Chipset Configuration MMCFG Base Use this item to select MMCFG Base. MMCFG Size Use this item to select MMCFG Size. MMIO High Base Use this item to select MMIO High Base. MMIO High Granularity Size Use this item to select MMIO Granularity Size. SR-IOV Support If system has SR-IOV capable PCIE Devices, this option Enables or Disables Single Root IO Virtualization Support.
Page 69
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Onboard LAN1/2/3 Use this to enable or disable the Onboard LAN1/2/3 function. VT-d Intel Virtualization Technology for Directed I/O helps the virtual machine monitor better utilize hardware by improving application compatibility and reliability, and providing ad- ditional levels of manageability, security, isolation, and I/O performance.
Page 70
PCI-E ASPM Support (Global) Select this item to disable ASPM Support in all PCIe root ports. MCIO3 ASPM Support Select this item to configure PCIE Active State Power Management settings. PCIE1/PCIE3/PCIE5/PCIE7 ASPM Support Enables or disables the ASPM support for all CPU downstream devices. Select [Auto] for the default value.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.5 Storage Configuration Hard Disk S.M.A.R.T. S.M.A.R.T stands for Self-Monitoring, Analysis, and Reporting Technology. It is a monitoring system for computer hard disk drives to detect and report on various indicators of reliability. SATA Controller 0/1 Use this item to enable or disable SATA Controllers.
3.3.6 NVMe Configuration NVMe Configuration The NVMe Configuration displays the NVMe controller and Drive information. Launch NVMe driver Select this item to enable or disable launch NVMe driver.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.7 ACPI Configuration PCIE Devices Power On Allow the system to be waked up by a PCIE device and enable wake on LAN. Ring-In Power On Use this item to enable or disable Ring-In signals to turn on the system from the power- soft-off mode.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.9 Super IO Configuration Serial Port 1 Configuration Use this item to set parameters of Serial Port 1 (COM1). Serial Port Use this item to enable or disable the serial port. Change Settings Use this item to select an optimal setting for Super IO device.
3.3.10 Serial Port Console Redirection COM1 / SOL Console Redirection Use this option to enable or disable Console Redirection. If this item is set to Enabled, it allows user to select a COM Port to be used for Console Redirection. Console Redirection Settings Use this option to configure Console Redirection Settings, and specify how the computer and the host computer to which are connected exchange information.
Page 77
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Bits Per Second Use this item to select the serial port transmission speed. The speed used in the host computer and the client computer must be the same. Long or noisy lines may require lower transmission speed. The options include [9600], [19200], [38400], [57600] and [115200].
Page 78
Out-of-Band Mgmt Port Microsof t Windows Emergency Management Services (EMS) allows for remote management of a Windows Server OS through a serial port. Terminal Type EMS Use this item to select the preferred terminal emulation type for out-of-band management. It is recommended to select [VT-UTF8]. Option Description VT100...
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.11 H/W Monitor In this section, it allows user to monitor the status of the hardware on the system, includ- ing the parameters of the CPU temperature, motherboard temperature, CPU fan speed, chassis fan speed, and the critical voltage.
3.3.12 Runtime Error Logging System Error Use this item to enable or disable System Error feature. When it is set to [Enabled], it allows user to configure Memory Error and PCIE Error log features. WHEA Support Use this item to enable or disable Windows Hardware Error Architecture. EMCA Logging Support Use this item to enable or disable EMCA Logging.
Page 81
SPC741D8-2T/BCM SPC741D8-2L2T/BCM PCIE Corrected Error Threshold PCIE Correctable Error Threshold (0x01-0xFF) used for sparing, tagging, and leaky bucket. PCIE Uncorrected Error Use this item to enable or disable PCIe Uncorrectable errors. PCIE Fatal Error Enable Use this item to enable or disable PCIe Ftal errors.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.14 Network Stack Configuration Network Stack Enable UEFI network stack can prevents to perform from the single-user network boots and network installation. If disabled, the host does not use the network interface. IPv4 PXE Support Enable IPv4 PXE Boot support. If disabled, IPv4 PXE Boot Option is not supported.
3.3.15 Intel® VMD technology Press <Enter> to bring up the Intel(R) VMD for Volume Management Device Configuration menu. Intel VMD for Volume Management Device on Socket 0 VMD Config for IOU0/IOU1/IOU2/IOU3/IOU4 Use this item to enable or disable Intel(R) Volume Management Device Technology in specific Stack.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.16 Driver Health Inter (R) PRO/1000 9.0.03 PCI-E Healthy Provides Health Status for the Drivers/Controllers Broadcom NXE Gigabit Ethernet Driver Healthy Provides Health Status for the Drivers/Controllers...
3.3.17 Tls Auth Configuration Server CA Configuration Press <Enter> to configure Server CA. Client Cert Configuration Press <Enter> to configure Client Cert. Enroll Cert Press <Enter> to enroll cert. Delete Cert Press <Enter> to delete cert.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.3.18 Instant Flash Instant Flash is a UEFI flash utility embedded in Flash ROM. This convenient UEFI update tool allows user to update system UEFI without entering operating systems first like MS- ® DOS or Windows . Just save the new UEFI file to the USB flash drive, floppy disk or hard drive and launch this tool, then update the UEFI only in a few clicks without preparing an additional floppy diskette or other complicated flash utility.
3.4 Server Mgmt Wait For BMC Wait For BMC response for specified time out. BMC starts at the same time when BIOS starts during AC power ON. It takes around 90 seconds to initialize Host to BMC interfaces. FRB-2 Timer Select this item to enable or disable FRB-2 timer (POST timer) FRB-2 Timer Timeout Select this item to define the FRB-2 Time Expiration between 1 to 30 value.
Page 89
SPC741D8-2T/BCM SPC741D8-2L2T/BCM OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires. If the OS Boot Watchdog Timer is disabled, this item is not available. BMC Network Configuration Select this item to configure BMC network parameters.
3.4.1 BMC Network Configuration Bonding Setting Select this item to enabled or disabled bonding. Please enable all lan channel first when want to enable bonding. Lan Channel (Failover) Manual Setting IPMI LAN If [No] is selected, the IP address is assigned by DHCP. Using a static IP address, toggle to [Yes], and the changes take effect after the system reboots.
Page 91
SPC741D8-2T/BCM SPC741D8-2L2T/BCM When [DHCP] or [Static] is selected, do NOT modify the BMC network settings on the IPMI web page. The default login information for the IPMI web interface is: Username: admin Password: admin For more instructions on how to set up remote control environment and use the IPMI man- agement platform, please refer to the IPMI Configuration User Guide or go to the Support website at: http://www.asrockrack.com/support/ipmi.asp...
3.4.2 System Event Log SEL Components Change this to enable ro disable event logging for error/progress codes during boot. Erase SEL Use this to choose options for earsing SEL. When SEL is Full Use this to choose options for reactions to a full SEL. Log EFI Status Codes Use this item to disable the logging of EFI Status Codes or log only error code or only progress code or both.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.4.3 BMC Tools KCS control Select the KSC interface state after POST end. If [Enabled] is selected, the BMC will remain KCS interface after POST stage. If [Disabled] is selected, the BMC will disable KCS interface after POST stage.
3.5 Security This section allows user to set or change the supervisor/user password for the system. For the user password item is also allowed to clear it. Supervisor Password Set or change the password for the administrator account. Only the administrator has authority to change the settings in the UEFI Setup Utility.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.5.1 Key Management In this section, expert users can modify Secure Boot Policy variables without full authenti- cation. Factory Key Provision Install factory default Secure Boot keys after the platform reset and while the System is in Setup mode.
Page 96
Platform Key(PK) Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate in: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2. Authenticated UEFI Variable 3. EFI PE/COFF Image(SHA256) Key Source: Factory, Modified, Mixed Key Exchange Keys(KEK) Enroll Factory Defaults or load certificates from a file: 1.
Page 97
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 2. Authenticated UEFI Variable 3. EFI PE/COFF Image(SHA256) Key Source: Factory, Modified, Mixed Forbidden Signatures(dbx) Enroll Factory Defaults or load certificates from a file: 1. Public Key Certificate in: a) EFI_SIGNATURE_LIST b) EFI_CERT_X509 (DER) c) EFI_CERT_RSA2048 (bin) d) EFI_CERT_SHAXXX 2.
SPC741D8-2T/BCM SPC741D8-2L2T/BCM 3.6 Event Logs Change Smbios Event Log Settings Select this item to configure the Smbios Event Log Settings. When entering the item, the screen displays following sub-items: Smbios Event Log Use this item to enable or disable all features of the SMBIOS Event Logging during system boot.
3.7 Boot Screen In this section, it displays the available devices on the system and allows user to configure the boot settings and the boot priority. Boot Option #1/#2/#3/#4/#5/#6 Use this item to set the system boot order. UEFI USB Drive BBS Priorities Specifies the Boot Device Priority sequence from available UEFI USB Drives.
Page 101
SPC741D8-2T/BCM SPC741D8-2L2T/BCM Full Screen Logo Use this item to enable or disable OEM Logo. The default value is [Enabled].
3.8 Exit Screen Save Changes and Exit When selecting this option, the following message “Save configuration changes and exit setup?” will pop-out. Press <F10> key or select [Yes] to save the changes and exit the UEFI SETUP UTILITY. Discard Changes and Exit When selecting this option, the following message “Discard changes and exit setup?”...
Please download the operating system from the OS manufacturer. Please refer to the OS documentation for more instructions. * Please download the Intel® SATA Floppy Image driver from the ASRock Rack’s website (www.asrockrack.com) to the USB drive while installing OS in SATA RAID mode.
Chapter 5 Troubleshooting 5.1 Troubleshooting Procedures Follow the procedures below to troubleshoot the system. Always unplug the power cord before adding, removing or changing any hardware components. Failure to do so may cause physical injuries and damages to motherboard components. 1.
Page 105
1. Verify if the battery on the motherboard provides ~3VDC. Install a new battery if it does not. 2. Confirm whether the power supply provides adaquate and stable power. Other problems... 1. Try searching keywords related to the related problem on ASRock Rack’s FAQ page: http://www.asrockrack.com/support...
5.2 Technical Support Procedures If the problems are still unsolved, please contact ASRock Rack’s technical support with the following information: 1. Contact information 2. Model name, BIOS version and problem type. 3. System configuration. 4. Problem description. Contact ASRock Rack’s technical support at: http://www.asrockrack.com/support/tsd.asp...
Page 107
Contact Information Contact ASRock Rack or want to know more about ASRock Rack, it's welcome to visit ASRock Rack’s website at http://www.asrockrack.com; or contact the dealer for further information. For technical questions, please submit a support request form at https://event.
Need help?
Do you have a question about the SPC741D8-2T/BCM and is the answer not in the manual?
Questions and answers