Texecom Ricochet INS742-2 Installation Manual
Texecom Ricochet INS742-2 Installation Manual

Texecom Ricochet INS742-2 Installation Manual

Wireless expansion kits

Advertisement

Quick Links

Ricochet® Wireless Expansion Kits
INS742-2
EN: Installation manual
FR: Manuel d'installation
NL: Installatiehandleiding
ES: Manual de instalación
IT: Manuale d'installazione
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ricochet INS742-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texecom Ricochet INS742-2

  • Page 1 Ricochet® Wireless Expansion Kits INS742-2 EN: Installation manual FR: Manuel d’installation NL: Installatiehandleiding ES: Manual de instalación IT: Manuale d’installazione...
  • Page 2: Example System

    EN: Installation Manual 1. Introduction The Ricochet® expansion kit is a quick and convenient way to add wireless devices to an existing wired security system. The existing system must have spare normally closed circuits to connect the zones and other outputs. Every expansion pack contains a relay module Premier Elite iXP-W and an 8 zone wireless Ricochet expander Premier Elite 8XP-W.
  • Page 3: Installation Flow Chart

    4. Installation flow chart Connect Expander to Relay Module 12V 0V T & R (Section 5) Set option switch 2 on Expander to ON Connect 12V, 0V & zones on Relay Module to Control Panel Learn devices to Expander (Section 6) (Expander tamper circuit open) Place devices in desired location Wait 15 minutes, then test the system NOTE: The system should be left for 15 minutes to allow the Ricochet devices to commission correctly.
  • Page 4: Learning Devices

    6. Learning devices Options switch 2 on the Expander should be ON. Address switches should be all off. Address & Option switches on the Relay Module should all be off. Devices are learned to the receiver using the built in learn switch and the LED array. To initiate the learn sequence press the Learn Switch on the receiver ONCE The right hand LED 1 will flash (for 20 seconds) Insert the batteries into device 1 within 20 seconds...
  • Page 5: Specifications

    The Premier Elite 8XP-W expander/Premier iXP-W module is covered by a 2 year warranty against defects in material or workmanship. As the Premier Elite 8 XP-W expander/ Premier iXP-W module is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the device failed to function correctly.
  • Page 6 Installation Instructions - Premier External TD-W 1. Accessing the unit & battery installation Remove the top cap and loosen screw Push up head unit and remove. (screw retained in wall plate). Start the learn process on the keypad and then insert the batteries - Battery connection will automatically start the learning sequence.
  • Page 7 2. Choosing a Location • Mounting height 1.0 - 1.4m (nominal 1.2m), measured to middle of unit. • Mount perpendicular to ground. ✓ Parallel 1.0 - 1.4m • Do not install close to large metal objects (eg. metal lintel) or mains wiring. •...
  • Page 8: Mounting The Unit

    3. Mounting the Unit Front View WALL MOUNTING REAR TAMPER To enable the rear tamper, the breakaway keyhole section must be securely fixed to the mounting surface. 4. Jumper Settings JP1: Pulse Count Pulse Count Sensitivity Night Only 2 3 4 H M L ON OFF 0.3 - 3.0m/s...
  • Page 9 5. Range Adjustment - PIR Bottom of head unit To adjust the range of the detector, rotate the circular section shown until the desired range is shown in the window. Note: Range can vary due to environmental conditions. To reduce the risk of false alarms always select the lowest range possible for the installation.
  • Page 10: Coverage Area

    6. Coverage Area Bottom of head unit Bottom of head unit Top View Top View Active Active detection detection coverage coverage 45˚ 90˚ 90˚ 90˚ 45˚ Walk-testing With the range, sensitivity, coverage and pulse count set as desired, enable the LEDs and walk-through the area of protection.
  • Page 11: Specifications & Standards

    Disclaimer: The Premier External TD-W is not a complete alarm system, but only its part. Therefore Texecom does not accept any responsibility or liability for any damage that is claimed to be a result of an incorrect functioning of the Premier External TD-W detector.
  • Page 12 Installation Instructions - Premier Elite OH-W Fig.1 Fig.2 HUSH/TEST BUTTON BATTERY COMPARTMENT Fig.3 Fig.4 >1m 100 mm (4 in.) minimum 100 mm (4 in.) >1m minimum >1m 230V 110V Contents: Wireless optical and heat fire detector (Premier Elite OH-W), Pack of screws and fixings3 AAA Duracell Procell MN2400 batteries (1.5 V1100mAh) or equivalent.
  • Page 13 Low Battery Detection: The Premier Elite OH-W is powered by 3 AAA batteries. The alarm regularly checks for a low battery. If a low battery is detected, the transmitter sends a low battery message to the control panel, that displays the alarm’s ID at low battery. In addition, the yellow LED of the alarm blinks every 12 seconds. The alarm’s sounder chirps every 48 seconds (yellow LED continues to blink) until the batteries are replaced.
  • Page 14: Maintenance

    The Premier Elite OH-W is designed to detect the presence of fire and activate an alarm control panel. As the Premier Elite OH-W is not a complete alarm system, but only a part therof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier Elite OH-W failed to function correctly.
  • Page 15: Mounting Locations

    Installation Instructions - Premier Elite CO-W 1. What is carbon monoxide? Carbon monoxide (CO) is a highly poisonous gas that has no taste, colour or smell. Potential Sources of CO • Wood-burning stoves • Oil and coal burning appliances • Fumes from integral garages •...
  • Page 16: Opening The Detector

    The CO-W operates either as a stand alone alarm or it Metal Lintel >1m can be connected to a Texecom Premier Elite wireless alarm system. Do not insert the batteries until you are ready to learn the device to the system. Battery connection will automatically start the learning sequence.
  • Page 17: Battery Installation/Replacement

    7. Installing the detector - free-standing NOTE: THIS ALARM MUST BE INSTALLED BY A COMPETENT PERSON AND IS TO BE INSTALLED ACCORDING TO THESE INSTRUCTIONS 1. Lift out the stand, on the back of the detector, from the bottom and click into place (as shown below). 2.
  • Page 18 13. What to do in the event of an alarm WARNING! Activation of the alarm indicates the presence of Carbon Monoxide (CO) which can kill you. If the alarm sounds (0.5 seconds on, 0.5 seconds off and flashing red light): •...
  • Page 19 The Premier Elite CO-W is protected by UK & International Registered Designs. Maintenance: Test yearly by the installer Premier Elite is a Trademark of Texecom Ltd. © 2015 Texecom Ltd. Warranty: 2 year replacement warranty (excludes battery) www.texe.com Ref: INS672-3...
  • Page 20 Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1706 233875 Email: techsupport@texe.com...

Table of Contents