Outdoor Unit - Sanyo 09KHS71 Installation Instructions Manual

Indoor/outdoor unit inverter split system air conditioner
Hide thumbs Also See for 09KHS71:
Table of Contents

Advertisement

05-423 KHS0971-1271
12/13/05

2-2. Outdoor Unit

AVOID:
heat sources, exhaust fans, etc. (Fig. 4)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air intake/
exhaust and possible maintenance. (Fig. 5a)
provide a solid base (level concrete pad, concrete
block, 4" ¥ 1'4" (10 ¥ 40 cm) beams or equal), a mini-
mum of 4" (10 cm) above ground level to reduce
humidity and protect the unit against possible water
damage and decreased service life. (Figs. 5b and 5c)
CAUTION
Install cushion rubber under unit's feet to reduce
vibration and noise. (Fig. 5d)
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
Install in a location where no antenna of a television
or radio exists within 10' (3 m).
1:23 PM
Page 5
A solid base must not cover
the hole of the bottom plate.
NO
Hot air
Outdoor unit
Air intake
Min. 2" (5 cm)
Min.
Air discharge
Min.
2" (5 cm)
8" (20 cm)
Fig. 5a
Drain holes
Fig. 5b
Air intake
Concrete
or equal
Fig. 5c
Fig. 5d
5
Exhaust fan
Heat source
Fig. 4
Obstacle above
Min.
Min.
7' (2 m)
7' (2 m)
Valve
side
Min. 10"
(25 cm)
Ground
Min. 2" (5 cm)
Air intake
Anchor bolts
(4 pcs.)
Min. 4" (10 cm)
Cushion rubber