Product Information
3.1.3

210L and 250L Dimensions and minimum clearances

• The following details cover the installation, service and maintenance
clearances for the product.
Note the dimensions and minimum clearances in the figures for all three
directions carefully. Note also the position of the door if installed in a
cupboard.
CAUTION
Risk of damage to product or property
The product will overheat if the clearance space around the product is
restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the product.
▶ This products contains electrical components, do not store any
combustible materials on or next to the product, such as clothes,
towels, paper or plastic bags.
TANK SIZE
HEIGHT
210
1561
250
1806
≥50
(if door in front)
≥600
(if fixed wall)
Fig. 5
Cylinder depth and height specifications (mm) and front, rear
and height clearances limitation (210 litre base drawing - note
height differences to 250 litre)
6
≥200
≥50
Height
table above
747
0010049196-001
674
(including pump connector plug)
≥150
Fig. 6
Cylinder width specifications (mm) and lateral clearances
limitation (both 210 and 250 litre, 210 litre base drawing)
Minimum overall depth ≥874
≥150
Minimum required door width ≥680
Fig. 7
Lateral clearance limitation and door frame minimum width
when installing in a cupboard with front door (both 210 and
250 litre)
Pre plumbed cylinder – 6 721 852 928 (2023/04)
≥150
574
745
0010049195-001
≥150
0010049306-001