10/100 16/24-port unmanaged fast ethernet switch (22 pages)
Summary of Contents for LG-Ericsson iPECS ES-2026P
Page 1
ES-2026/ES-2026P S E R U I D E Installation Manual iPECS is an Ericsson-LG Brand Please read this manual carefully before operating your set. Retain it for future reference.
Page 2
N S T A L L A T I O N ANUAL ES-2026 / ES-2026P ES-2026 A 26-P FE S DVANCED MART WITCH Layer 2 Advanced Smart Switch with 24 10/100BASE-TX (RJ-45) Ports, and 2 Gigabit Combination Ports (RJ-45/SFP) ES-2026P A 26-P FE P DVANCED...
OMPLIANCES AND AFETY TATEMENTS ES-2026 / ES-2026P FCC C LASS This device complies with Part 15 rules. Operation is subject to the following two conditions; This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
Page 4
OMPLIANCES ES-2026 / ES-2026P for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied: The following declaration is for two models: (ES-2026/ES-2026P) RFI Emission: Limit class A according to EN 55022:2006+A1:2007 ◆...
Page 5
OMPLIANCES ES-2026 / ES-2026P AFETY OMPLIANCE SAFETY INSTRUCTION This product complies with and conforms to the following international Product Safety standards as applicable: ◆ Safety of Information Technology Equipment, IEC(EN) 60950-1, including all relevant national deviations as listed in Compliance with IEC for Electrical Equipment (IECEE) Safety of Information Technology Equipment, CAN/CSA-C22.2 No.
Page 6
OMPLIANCES ES-2026 / ES-2026P Power Cord Set U.S.A. and The cord set must be UL-approved and CSA certified. Canada The minimum specifications for the flexible cord are: - No. 18 AWG - not longer than 2 meters, or 16 AWG. - Type SV or SJ - 3-conductor The cord set must have a rated current capacity of at...
Page 7
OMPLIANCES ES-2026 / ES-2026P que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions. France et Pérou uniquement: Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté...
Page 8
OMPLIANCES ES-2026 / ES-2026P Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich ◆ sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden. ◆ Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen (Sicherheitskleinstspannung) gemäß...
Page 9
OMPLIANCES ES-2026 / ES-2026P Waste reduction and safe disposal of all harmful un-recyclable by- ◆ products. Recycling of all reusable waste content. ◆ Design of products to maximize recyclables at the end of the product’s ◆ life span. Continual monitoring of safety standards. ◆...
BOUT UIDE ES-2026 / ES-2026P This guide details the hardware features of the switches, including the URPOSE physical and performance-related characteristics, and how to install the switches. The guide is intended for use by network administrators who are UDIENCE responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
ONTENTS ES-2026 / ES-2026P OMPLIANCES AND AFETY TATEMENTS BOUT UIDE ONTENTS IGURES ABLES NTRODUCTION Overview Switch Architecture Network Management Options Power-over-Ethernet Description of Hardware 10/100BASE-TX Ports SFP Transceiver Slots Port and System Status LEDs Mode Button (ES-2026P) Power Supply Inlet Grounding Point Reset Button Features and Benifits...
Page 12
ONTENTS ES-2026 / ES-2026P Network Aggregation Plan Remote Connections with Fiber Cable Making VLAN Connections Application Notes NSTALLING THE WITCH Selecting a Site Ethernet Cabling Equipment Checklist Optional Rack-Mounting Equipment Mounting Rack Mounting Desktop or Shelf Mounting Connecting to a Power Source Installing an Optional SFP Transceiver AKING ETWORK...
NTRODUCTION ES-2026 / ES-2026P VERVIEW The ES-2026 and ES-2026P are Fast Ethernet Layer 2 switches with 24 10/ 100BASE-TX ports, and two Small Form Factor Pluggable (SFP) transceiver slots that operate in combination with 1000BASE-T ports 25~26 (see Figure 1, ports 25-26). The ES-2026P also provides PoE power to connected devices.
| Introduction HAPTER Switch Architecture ES-2026 / ES-2026P WITCH RCHITECTURE These switches employ a wire-speed, non-blocking switching fabric. This permits simultaneous wire-speed transport of multiple packets at low latency on all ports. The switch also features full-duplex capability on all ports, which effectively doubles the bandwidth of each connection.
| Introduction HAPTER Description of Hardware ES-2026 / ES-2026P ESCRIPTION OF ARDWARE The switches contain 24 RJ-45 ports that operate at 10 Mbps or 100 Mbps, 10/100BASE-TX half or full duplex. Because all ports on these switches support automatic ORTS MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
| Introduction HAPTER Description of Hardware ES-2026 / ES-2026P These switches include a display panel for key system and port indications ORT AND YSTEM that simplify installation and network troubleshooting. The LEDs, which are TATUS located on the front panel for easy viewing, are shown below and described in the following tables.
| Introduction HAPTER Description of Hardware ES-2026 / ES-2026P When the Mode button is depressed, the port LEDs display PoE information. UTTON When the Mode button is not depressed, the port LEDs display link and (ES-2026P) activity information. There is one power inlet on the rear panel of the switch. The standard OWER UPPLY NLET...
| Introduction HAPTER Features and Benifits ES-2026 / ES-2026P If you encounter any switch malfunctions, such as a hang or ESET UTTON nonrecoverable error, you might want to reset the switch to its default configuration by pressing and holding the reset button for more than ten seconds.
ETWORK LANNING ES-2026 / ES-2026P NTRODUCTION WITCHING A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
| Network Planning HAPTER Application Examples ES-2026 / ES-2026P In the figure below, the ES-2026P Fast Ethernet Switch is operating as a collapsed backbone for a small LAN. It is providing dedicated 10 Mbps full- duplex connections to workstations and 100 Mbps full-duplex connections to power users, and 1 Gbps full-duplex connections to servers.
| Network Planning HAPTER Application Examples ES-2026 / ES-2026P With 26 parallel bridging ports (i.e., 26 distinct collision domains), these ETWORK switches can collapse a complex network down into a single efficient GGREGATION bridged node, increasing overall bandwidth and throughput. In the figure below, the 10/100BASE-TX ports on the switch are providing 100 Mbps connectivity for up to 24 segments, while the 1000BASE-T ports are providing connectivity for 48 Gigabit segments.
| Network Planning HAPTER Application Notes ES-2026 / ES-2026P These switches support VLANs which can be used to organize any group of VLAN AKING network nodes into separate broadcast domains. VLANs confine broadcast ONNECTIONS traffic to the originating group, and can eliminate broadcast storms in large networks.
| Network Planning HAPTER Application Notes ES-2026 / ES-2026P 1000BASE-LX: 10 km (6.2 miles) for single-mode fiber. ■ 1000BASE-LH: 70 km (43.5 miles) for single-mode fiber. ■ However, power budget constraints must also be considered when calculating the maximum cable length for your specific environment. –...
NSTALLING THE WITCH ES-2026 / ES-2026P This chapter describes how to install the switches. ELECTING A ◆ The site should: be at the center of all the devices you want to link and near a power ■ outlet. be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) ■...
| Installing the Switch HAPTER Equipment Checklist ES-2026 / ES-2026P Electrical surge suppression ◆ Separation of electrical wires (switch related or other) and ◆ electromagnetic fields from data based network wiring Safe connections with no damaged cables, connectors or shields ◆...
| Installing the Switch HAPTER Optional Rack-Mounting Equipment ES-2026 / ES-2026P PTIONAL OUNTING QUIPMENT If you plan to rack-mount the switch, be sure to have the following equipment available: Four mounting screws for each device you plan to install in a rack— ◆...
| Installing the Switch HAPTER Mounting ES-2026 / ES-2026P To rack-mount devices: Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. Figure 14: Attaching the Brackets Mount the device in the rack, using four rack-mounting screws (not provided).
| Installing the Switch HAPTER Connecting to a Power Source ES-2026 / ES-2026P Attach the four adhesive feet to the bottom of the first switch. ESKTOP OR HELF OUNTING Figure 16: Attaching the Adhesive Feet Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow.
| Installing the Switch HAPTER Installing an Optional SFP Transceiver ES-2026 / ES-2026P For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the wall socket type in your country.
Page 34
| Installing the Switch HAPTER Installing an Optional SFP Transceiver ES-2026 / ES-2026P SFP transceivers are not provided in the switch package. – 34 –...
AKING ETWORK ONNECTIONS ES-2026 / ES-2026P ONNECTING ETWORK EVICES The switches are designed to be connected to 10, 100, or 1000 Mbps network cards in PCs and servers, as well as to other switches and hubs. It may also be connected to remote devices using optional 1000BASE-SX, 1000BASE-LX, 1000BASE-LH, or 100BASE-FX SFP transceivers.
| Making Network Connections HAPTER Twisted-Pair Devices ES-2026 / ES-2026P The RJ-45 ports on the switches support automatic MDI/MDI-X pinout ABLING UIDELINES configuration, so you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, routers, or hubs).
| Making Network Connections HAPTER Twisted-Pair Devices ES-2026 / ES-2026P Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment connected to the hub.
| Making Network Connections HAPTER Fiber Optic SFP Devices ES-2026 / ES-2026P Figure 20: Network Wiring Connections Switch Equipment Rack (side view) Punch-Down Block Patch Panel Wall SFP D IBER PTIC EVICES An optional Gigabit SFP (1000BASE-SX, 1000BASE-LX, 1000BASE-LH, or 100BASE-FX) transceiver can be used for a backbone connection between switches, or for connecting to a high-speed server.
| Making Network Connections HAPTER Fiber Optic SFP Devices ES-2026 / ES-2026P These switches use lasers to transmit signals over fiber optic ARNING cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.
| Making Network Connections HAPTER Connectivity Rules ES-2026 / ES-2026P The 100BASE-FX fiber optic ports operate at 100 Mbps, full duplex, with auto-negotiation of flow control. The maximum length for fiber cable operating at 100 Mbps is listed under “100 Mbps Fast Ethernet Collision Domain”...
| Making Network Connections HAPTER Cable Labeling and Connection Records ES-2026 / ES-2026P Table 7: Maximum 1000BASE-LH Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9/125 micron single- 2 m - 70 km mode fiber (7 ft - 43.5 miles) 100 M Table 8: Maximum 100BASE-FX Cable Length THERNET...
Page 42
| Making Network Connections HAPTER Cable Labeling and Connection Records ES-2026 / ES-2026P Differentiate between racks by naming accordingly. ◆ Label each separate piece of equipment. ◆ ◆ Display a copy of your equipment map, including keys to all abbreviations at each equipment rack. –...
ROUBLESHOOTING ES-2026 / ES-2026P LED I IAGNOSING NDICATORS Table 11: LED Indicators LED Status Action PWR LED is Off ◆ Check connections between the switch, the power cord, and the wall outlet. ◆ Contact your dealer for assistance. PWR LED is Amber ◆...
| Troubleshooting PPENDIX In-Band Access ES-2026 / ES-2026P CCESS You can access the management agent in the switch from anywhere within the attached network using a web browser, or other network management software tools. However, you must first configure the switch with a valid IP address, subnet mask, and default gateway.
ABLES AND INOUTS ES-2026 / ES-2026P WISTED ABLE SSIGNMENTS For 10/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, green with white stripes.
| Cables and Pinouts PPENDIX Twisted-Pair Cable Assignments ES-2026 / ES-2026P Table 12: 10/100BASE-TX MDI and MDI-X Port Pinouts MDI Signal Name MDI-X Signal Name Transmit Data plus (TD+) Receive Data plus (RD+) Transmit Data minus (TD-) Receive Data minus (RD-) Receive Data plus (RD+) Transmit Data plus (TD+) Receive Data minus (RD-)
| Cables and Pinouts PPENDIX Twisted-Pair Cable Assignments ES-2026 / ES-2026P Figure 24: Crossover Wiring EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable White/Orange Stripe Orange White/Green Stripe End A End B Blue White/Blue Stripe Green White/Brown Stripe Brown All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can 1000BASE-T P use straight-through cables for all network connections to PCs or servers, SSIGNMENTS...
| Cables and Pinouts PPENDIX Fiber Standards ES-2026 / ES-2026P ABLE ESTING FOR XISTING ATEGORY ABLE Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test parameters for Return Loss and Equal-Level Far- End Crosstalk (ELFEXT).
Page 49
| Cables and Pinouts PPENDIX Fiber Standards ES-2026 / ES-2026P Table 14: Fiber Standards ITU-T Standard Description Application G.654 1550-nm Loss-Minimized Fiber Extended long-haul applications. Optimized for high-power Single-mode, 9/125-micron core transmission in the 1500 to 1600-nm region, with low loss in the 1550-nm band.
| Hardware Specifications PPENDIX Switch Features ES-2026 / ES-2026P (W x D x H) ES-2026P: 44.0 x 28.0 x 4.4 cm (17.32 x 11.0 x 1.73 in.) ES-2026: 44.0 x 21 x 4.4 cm (17.32 x 8.27 x 1.73 in.) Operating: 0°C to 50°C (32°F to 122°F) EMPERATURE Storage: -40°C to 70°C (-40°F to 158°F)
| Hardware Specifications PPENDIX Management Features ES-2026 / ES-2026P Full Duplex: IEEE 802.3x ONTROL Half Duplex: Back pressure ANAGEMENT EATURES Web, or SNMP manager ANAGEMENT TANDARDS IEEE 802.3-2005 Ethernet, Fast Ethernet, Gigabit Ethernet Full-duplex flow control Link Aggregation Control Protocol IEEE802.3at Power-over-Ethernet Draft standard version IEEE 802.1Q IEEE 802.1P...
LOSSARY ES-2026 / ES-2026P IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 10BASE-T 4, or 5 UTP cable. IEEE 802.3 specification for 100 Mbps Ethernet over two strands of 50/125, 100BASE-FX 62.5/125 micron, or 9/125 micron core fiber cable. IEEE 802.3u specification for 100 Mbps Ethernet over two pairs of Category 100BASE-TX 5 UTP cable.
Page 54
LOSSARY ES-2026 / ES-2026P A workstation, server, or other device that does not forward traffic. TATION A network communication system developed and standardized by DEC, THERNET Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable. The successor IEEE 802.3 standard provides for integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber, thin coax and twisted-pair cable.
Page 55
LOSSARY ES-2026 / ES-2026P A group of interconnected computer and support devices. OCAL ETWORK (LAN) A portion of the networking protocol that governs access to the EDIA CCESS transmission medium, facilitating the exchange of data between network (MAC) ONTROL nodes. An acronym for Management Information Base.
Page 57
NDEX ES-2026 / ES-2026P physical characteristics AC input aggregate bandwidth buffer architecture humidity LEDs maximum current network interface ports power consumption power supply size switching database temperature weight PoE connections PoE Ethernet connections port and system status LEDs power and cooling problems power inlet Power-over-Ethernet rack mounting...