Advertisement

Quick Links

FusionServer 2288H V5 Server
Technical White Paper
Issue
11
Date
2023-04-30
xFusion Digital Technologies Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FusionServer 2288H V5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fusion FusionServer 2288H V5

  • Page 1 FusionServer 2288H V5 Server Technical White Paper Issue Date 2023-04-30 xFusion Digital Technologies Co., Ltd.
  • Page 2 Copyrights © xFusion Digital Technologies Co., Ltd. 2023. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of xFusion Digital Technologies Co., Ltd. Trademarks and Permissions and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd.
  • Page 3: About This Document

    Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 2288H V5 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
  • Page 4 FusionServer 2288H V5 Server Technical White Paper About This Document Change History Issue Date Description 2023-04-30 Updated 6.1 Technical Specifications. 2023-03-31 Updated A.3 Operating Temperature Limitations . 2022-12-30 Optimized 5.5.1 Drive Configuration. 2022-11-30 Updated A.4 Nameplate . 2022-11-11 ⚫ Updated 5.5.1 Drive Configuration and 5.5.2 Drive Numbering.
  • Page 5: Table Of Contents

    FusionServer 2288H V5 Server Technical White Paper Contents Contents About This Document ......................ii 1 Product Introduction ...................... 1 2 Features ........................... 2 3 Physical Structure ......................5 4 Logical Structure ......................7 5 Hardware Description ..................... 9 5.1 Front Panel ............................9 5.1.1 Appearance ............................
  • Page 6 FusionServer 2288H V5 Server Technical White Paper Contents 5.5.1 Drive Configuration ..........................37 5.5.2 Drive Numbering ..........................46 5.5.3 Drive Indicators ..........................54 5.5.4 RAID Controller Card .........................56 5.6 Network ..............................56 5.6.1 LOMs ..............................56 5.6.2 FlexIO Cards ............................59 5.7 I/O Expansion ............................63 5.7.1 PCIe Cards ............................63 5.7.2 PCIe Slots ............................64...
  • Page 7: Product Introduction

    Technical White Paper 1 Product Introduction Product Introduction FusionServer 2288H V5 (2288H V5) is a new-generation 2U 2-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 2288H V5 is ideal for IT core services, cloud computing, high-performance computing, distributed storage, big data processing, enterprise or telecom applications, and other complex workloads.
  • Page 8: Features

    FusionServer 2288H V5 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ⚫ Powered by two Intel Xeon Scalable Skylake or Cascade Lake processors, the server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and two 10.4 GT/s UPI links between the processors, which deliver supreme processing...
  • Page 9 FusionServer 2288H V5 Server Technical White Paper 2 Features ⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times more I/O operations per second (IOPS) than a typical hard disk drive (HDD). The use of all SSDs provides higher I/O performance than the use of all HDDs or a combination of HDDs and SSDs.
  • Page 10 FusionServer 2288H V5 Server Technical White Paper 2 Features The BIOS firmware digital signature update mechanism is supported. During − the upgrade, the digital signature is verified to prevent unauthorized BIOS firmware upgrade. The flash security protection mechanism is supported to prevent −...
  • Page 11: Physical Structure

    FusionServer 2288H V5 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 2288H V5 physical structure (example: 12 x 3.5" drives) I/O module 1 I/O module 2 Power supply unit (PSU) I/O module 3 Chassis (Optional) built-in drive...
  • Page 12 FusionServer 2288H V5 Server Technical White Paper 3 Physical Structure FlexIO Mainboard RAID controller card TPM/TCM Memory Processor Heat sink a: Install either the air duct or built-in drive module. Issue 11 (2023-04-30) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 13: Logical Structure

    FusionServer 2288H V5 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 2288H V5 logical structure ® ® ⚫ The server supports one or two Intel Xeon Scalable processors. ⚫ The server supports up to 24 memory modules.
  • Page 14 FusionServer 2288H V5 Server Technical White Paper 4 Logical Structure ⚫ Uses the BMC management chip, and supports a VGA, a management network port, a debugging serial port, and other management ports. ⚫ The BMC management chip can be an enhanced management chip (VB) or an ordinary management chip.
  • Page 15: Hardware Description

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 Front Panel 5.2 Rear Panel 5.3 Processor 5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fans 5.10 Boards 5.1 Front Panel 5.1.1 Appearance ⚫...
  • Page 16 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Slide-out label plate (with an SN label) ⚫ 8 x 3.5" drive configuration Figure 5-2 Front view Drives Slide-out label plate (with an SN label) ⚫ 12 x 3.5" drive configuration...
  • Page 17 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-4 Front view Drives Filler module Slide-out label plate (with an SN label) ⚫ 24 x 2.5" drive configuration Figure 5-5 Front view Drives Slide-out label plate (with an SN label) ⚫...
  • Page 18: Indicators And Buttons

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description an SN label) 5.1.2 Indicators and Buttons Indicator and Button Positions ⚫ 8 x 2.5" drive configuration Figure 5-7 Indicators and buttons on the front panel Connection status indicator Connection status indicator...
  • Page 19 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description UID button/indicator Power button/indicator ⚫ 12 x 3.5" drive configuration Figure 5-9 Indicators and buttons on the front panel Connection status indicator Connection status indicator for 10GE LOM port 1...
  • Page 20 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-11 Indicators and buttons on the front panel Connection status indicator Connection status indicator for 10GE LOM port 1 for 10GE LOM port 2 Connection status indicator Connection status indicator...
  • Page 21 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Indicator and Button Descriptions Table 5-1 Description of indicators and buttons on the front panel Sign Indicator and Description Button Fault ⚫ ---: The device is operating properly. diagnosis LED ⚫...
  • Page 22: Ports

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Indicator and Sign Description Button Health status Off: The device is powered off or is faulty. ⚫ indicator Blinking red at 1 Hz: A major alarm has been ⚫ generated on the system.
  • Page 23 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-13 Ports on the front panel USB 2.0 ports USB 3.0 port VGA port ⚫ 8 x 3.5" drive configuration Figure 5-14 Ports on the front panel USB 2.0 ports ⚫...
  • Page 24 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-16 Ports on the front panel USB 2.0 ports ⚫ 24 x 2.5" drive configuration Figure 5-17 Ports on the front panel USB 2.0 ports USB 3.0 port VGA port ⚫...
  • Page 25: Rear Panel

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Port Description Table 5-2 Ports on the front panel Note Port Type Quantity Description VGA port DB15 Used to connect a display terminal, such as a monitor or KVM. USB port USB 2.0...
  • Page 26: Indicators

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ I/O modules 1, 2 and 3 can be configured with drive modules or PCIe riser modules. ⚫ The preceding figure is for reference only. 5.2.2 Indicators Indicator Positions Figure 5-20 Indicators on the rear panel...
  • Page 27 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Blinking green at 4 Hz: The firmware is being ⚫ upgraded online. Steady green: The power input and output are normal. ⚫ ⚫ Steady orange: The input is normal, but no power output is supplied.
  • Page 28: Ports

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description 5.2.3 Ports Port Positions Figure 5-21 Ports on the rear panel LOM port 1 VGA port LOM port 2 Management network port Serial port USB 3.0 port PSU socket Port Description...
  • Page 29: Processor

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Tool Type Quantity Description can also set it as the iBMC serial port by using the iBMC command. NOTE The port uses 3-wire serial communication interface, and the default baud rate is 115,200 bit/s.
  • Page 30: Memory

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-22 Processor positions 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. Figure 5-23 Memory identifier Issue 11 (2023-04-30) Copyright ©...
  • Page 31: Memory Subsystem Architecture

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Callout Description Definition Capacity of the memory module 8 GB ⚫ ⚫ 16 GB 32 GB ⚫ ⚫ 64 GB 128 GB ⚫ Number of ranks of the memory ⚫...
  • Page 32: Memory Compatibility

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K) F (primary) DIMM050(F) DIMM051(L) CPU 2 A (primary) DIMM100(A) DIMM101(G) B (primary) DIMM110(B) DIMM111(H)
  • Page 33 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ A server must use the same model of DDR4 DIMMs, and all the DIMMs operate at the same speed, which is the smallest value of: ⚫ Memory speed supported by a processor ⚫...
  • Page 34: Dimm Installation Rules

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-6 DDR4 memory specifications Parameter Specifications Maximum capacity per DDR4 DIMM (GB) Rated speed (MT/s) 2933 Operating voltage (V) Maximum number of DDR4 DIMMs in a server Maximum DDR4 memory capacity of the server (GB)
  • Page 35: Memory Installation Positions

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Each processor supports two integrated memory controllers (IMCs). At ◼ least two channels of each IMC are used for installing memory modules (channels 1 and 2, or channels 1, 2, and 3). The installed memory modules must be identical in size and organization.
  • Page 36: Memory Protection Technologies

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-25 DDR4 memory installation guidelines (1 processor) Figure 5-26 DDR4 memory installation guidelines (2 processors) 5.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ ⚫ Full mirroring ⚫...
  • Page 37: Dcpmm

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ Rank sparing mode ⚫ Static virtual lockstep ⚫ Faulty DIMM isolation ⚫ Memory thermal throttling ⚫ Memory address parity protection ⚫ Memory demand/patrol scrubbing ⚫ Device tagging ⚫ Data scrambling ⚫...
  • Page 38: Memory Subsystem Architecture

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Callout Description Example SN QR code 8089-A2-1839-00001931 5.4.2.2 Memory Subsystem Architecture The 2288H V5 provides 24 memory slots. Each processor integrates six memory channels, and each memory channel supports up to one DCPMM.
  • Page 39: Memory Compatibility

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot F (primary) DIMM150(F) DIMM151(L) 5.4.2.3 Memory Compatibility Observe the following rules when configuring DC persistent memory modules (DCPMMs): ⚫ The DCPMMs must be used with the DDR4 memory modules. For details, see the FusionServer DCPMM User Guide.
  • Page 40: Dimm Installation Rules

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Item Specifications Capacity per DCPMM (GB) Rated speed (MT/s) 2666 2666 2666 Operating voltage (V) Maximum number of DCPMMs in a server Maximum capacity of the server 2304 4608 7680...
  • Page 41: Memory Installation Positions

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Maximum Memory Capacity Supported by a CPU (DDR4 and CPU Type DCPMM Capacities) M series 2 TB L series 4.5 TB 5.4.2.5 Memory Installation Positions A 2288H V5 supports a maximum of 12 DCPMMs. The DCPMMs must be used with DDR4 DIMMs.
  • Page 42: Memory Protection Technologies

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-30 DCPMM and DDR4 memory configuration guidelines (2 processors) Figure 5-31 DCPMM and DDR4 memory configuration guidelines 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫...
  • Page 43: Storage

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ DCPMM DDR-T fault tolerance ⚫ Faulty DCPMM isolation 5.5 Storage 5.5.1 Drive Configuration Table 5-10 Drive configuration Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of...
  • Page 44 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives drives. must be drives. installed in slot 8 x 3.5" drive ⚫...
  • Page 45 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives to 11 to 41 + 1 x PCIe support support...
  • Page 46 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives drives. drives. ⚫ I/O module 2: 2 x 3.5" Slots 42 −...
  • Page 47 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives configuration Slots 0 Slots 40 − − to 11 to 41...
  • Page 48 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives I/O module card: RAID ⚫ 3: 4 x 2.5" controller...
  • Page 49 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives to 23 to 47 plug-in RAID support support controller card...
  • Page 50 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives to 24 to 41 Screw-in RAID support support controller only...
  • Page 51 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Normal Drive Number of Number of Number of Management Front Drives Rear Drives Built-in Mode Drives Slots 44 configured − to 47 in I/O support module 1...
  • Page 52: Drive Numbering

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description 5.5.2 Drive Numbering When the common hard drive management mode is PCH, each SATA drive has a fixed ATA number. ATA numbers provided in this section are based on the assumption that the hard drive management mode is PCH.
  • Page 53 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-34 Drive numbering ⚫ 12 x 3.5" drive EXP configuration 1 Figure 5-35 Drive numbering (I/O module 1 with 2 x 3.5" SAS/SATA drives) ⚫ 12 x 3.5" drive EXP configuration 2 Issue 11 (2023-04-30) Copyright ©...
  • Page 54 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-36 Drive numbering ⚫ 12 x 3.5" drive EXP configuration 3 Figure 5-37 Drive numbering ⚫ 12 x 3.5" drive EXP configuration 4 Issue 11 (2023-04-30) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 55 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-38 Drive numbering ⚫ 12 x 3.5" drive pass-through configuration 1 Figure 5-39 Drive numbering ⚫ 12 x 3.5" drive pass-through configuration 2 Figure 5-40 Drive numbering Issue 11 (2023-04-30)
  • Page 56 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-11 SATA drive numbers Drive No. ATA No. ATA3 ATA4 ATA5 ATA6 ATA7 ATA8 ATA9 ATA10 ATA11 ATA12 ATA13 ATA14 ⚫ 12 x 3.5" drive pass-through configuration 3 Issue 11 (2023-04-30)
  • Page 57 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-41 Drive numbering ⚫ 12 x 3.5" drive pass-through configuration 4 Figure 5-42 Drive numbering ⚫ 20 x 2.5" (8 x SAS/SATA + 12 x NVMe) drive configuration Issue 11 (2023-04-30)
  • Page 58 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-43 Drive numbering Table 5-12 SATA drive numbers Drive No. ATA No. ATA3 ATA4 ATA5 ATA6 ATA7 ATA8 ATA9 ATA10 ⚫ 24 x 2.5" drive configuration Figure 5-44 Drive numbering Issue 11 (2023-04-30) Copyright ©...
  • Page 59 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-13 SATA drive numbers Drive No. ATA No. ATA3 ATA4 ATA5 ATA6 ⚫ 25 x 2.5" drive EXP configuration 1 Figure 5-45 Drive numbering ⚫ 25 x 2.5" drive EXP configuration 2 Figure 5-46 Drive numbering ⚫...
  • Page 60: Drive Indicators

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-47 Drive numbering 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-48 SAS/SATA drive indicators Table 5-14 Description of SAS/SATA drive indicators Activity Indicator Fault Indicator Description (Green) (Yellow) The drive is not in position.
  • Page 61 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description NVMe Drive Indicators Figure 5-49 NVMe drive indicators ⚫ If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives support surprise hot swap. Table 5-15 NVMe drive indicators (VMD enabled)
  • Page 62: Raid Controller Card

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Steady on/Off Steady on The NVMe drive is faulty. M.2 FRU Indicators Figure 5-50 M.2 FRU indicators Table 5-17 M.2 FRU indicator description...
  • Page 63 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-18 LOM description Chip Port Numb Rate Supported Rates Not Type Model Type er of Negotiatio Rates Supported Ports n Mode LOMs X722 10GE Auto-negoti 10000M 10/100/100 optical ation...
  • Page 64 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-51 LOM port (Optional) 10GE optical (Optional) 10GE optical port (LOM port 1) port (LOM port 2) (Optional) 10GE electrical (Optional) 10GE electrical port (LOM port 1) port (LOM port 2)
  • Page 65: Flexio Cards

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Data transmission rate Connection status indicator for a 10GE indicator/Data transmission electrical port status indicator for a 10GE electric port Data transmission status Connection status indicator indicator of a GE electrical...
  • Page 66 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ The FlexIO card (with electrical ports) cannot be connected to power over Ethernet (PoE) devices (such as a switch with PoE enabled). Otherwise, link communication failure or even damage to the FlexIO card may be caused.
  • Page 67 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-54 SM211 network port indicators ⚫ SM233 with two 10GE electrical ports Figure 5-55 SM233 network port indicators ⚫ SM251 with two 56G IB optical ports Figure 5-56 SM251 network port indicators ⚫...
  • Page 68 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-21 FlexIO card indicator description Port Type Indicator Description GE electrical port Data transmission Off: No data is being transmitted. ⚫ status indicator Blinking yellow: Data is being ⚫...
  • Page 69: I/O Expansion

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Port Type Indicator Description transmission Blinking green: Data is being ⚫ status indicator transmitted. Steady green: The network port is ⚫ properly connected. 56G IB optical port Connection status ⚫...
  • Page 70: Pcie Slots

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description 5.7.2 PCIe Slots PCIe Slots Figure 5-59 PCIe slots ⚫ I/O module 1 provides slots 1 to 3. If a dual-slot PCIe riser module is used, slot 2 is unavailable.
  • Page 71 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-60 PCIe riser module 1 ⚫ PCIe riser module 2 (universal) − It provides PCIe slots 1, 2, and 3 when being installed in I/O module 1. It provides PCIe slots 4, 5, and 6 when being installed in I/O module 2.
  • Page 72 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-61 PCIe riser module 2 ⚫ PCIe riser module 3 (for GPUs only) It provides PCIe slots 1 and 3 when being installed in I/O module 1. − It provides PCIe slots 4 and 6 when being installed in I/O module 2.
  • Page 73 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description ⚫ PCIe riser module 4 (for T4 GPUs only) Provides PCIe slots 1 and 3 when installed in I/O module 1. Figure 5-63 PCIe riser module 4 ⚫ PCIe riser module 5 Provides PCIe slots 7 and 8 when installed in I/O module 3.
  • Page 74 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-65 PCIe riser module 6 ⚫ PCIe riser module 7 (rear drives and a PCIe Riser card) Provides PCIe slot 3 when installed in I/O module 1. Figure 5-66 PCIe riser module 7 Issue 11 (2023-04-30) Copyright ©...
  • Page 75: Pcie Slot Description

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description 5.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. Table 5-22 PCIe slot description PCIe PCIe Conne Port Root Devic Slot Slot Stand ctor...
  • Page 76 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Devic Slot Slot Stand ctor Width Port Size ards Width (B/D/F (B/D/F Slot 4 CPU 2 PCIe ⚫ 2-sl Port1A 85/00/ 86/00/ FHFL 3-sl ⚫...
  • Page 77: Psus

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Devic Slot Slot Stand ctor Width Port Size ards Width (B/D/F (B/D/F the server is fully configured with PCIe devices. The values may vary if the server is not fully configured with PCIe devices or if a PCIe card with a PCI bridge is configured.
  • Page 78: Fans

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-67 PSU positions 5.9 Fans ⚫ The server supports four fan modules. ⚫ The fan modules are hot-swappable. ⚫ The server tolerates failure of a single fan. ⚫ The fan speed can be adjusted.
  • Page 79: Boards

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description 5.10 Boards 5.10.1 Mainboard BOM code for mainboards of enhanced management chip (VB): 0302021706, 0302Y076. ⚫ BOM code for mainboards of normal management chip: 03024AFQ, 03026NEA, 06410432, ⚫ 03024CXS, 03029JRP, 06410436, 06410592.
  • Page 80 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description VGA connector (VGA 10GE optical port (10GE CONN/J112) PORT2/J132) or 10GE electrical port (10GE PORT2/J101) 10GE optical port (10GE VROC key port (J130) PORT1/J131) or 10GE electrical port (10GE PORT1/J100)
  • Page 81: Drive Backplane

    FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description (CPU2 SLIMLINE A/J140) (CPU2 SLIMLINE B/J139) PSU 2 connector (J157) PSU 1 connector (J156) Inner drive low-speed Left mounting ear signal connector (INNER connector (LCIA HDD BP/J122) BOARD/J161) Jumper (J176)
  • Page 82 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description DVD drive power connector Mini-SAS HD connector (J11) (PORT B/J29) Mini-SAS HD connector Power connector (J24) (PORT A/J28) ⚫ 12 x 3.5" drive EXP backplane Figure 5-71 12 x 3.5" drive EXP backplane (BOM: 03024DDH, 03024MSG,...
  • Page 83 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description (PORT B/J29) connector (J1) Mini-SAS HD connector Indicator signal cable (PORT A/J28) connector (J31) Power connector (J24) ⚫ 20 x 2.5" (8 x SAS/SATA + 12 x NVMe) drive backplane The 20 x 2.5"...
  • Page 84 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-74 20 x 2.5" (8 x SAS/SATA + 12 x NVMe) drive backplane (BOM: 03025EUL) ⚫ 24 x 2.5" drive pass-through backplane Figure 5-75 24 x 2.5" drive pass-through backplane (BOM: 03022JWW, 03029WFE)
  • Page 85 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-76 24 x 2.5" NVMe backplane (BOM: 03023WAD) Slimline A connector (J6) Slimline B connector (J5) Slimline C connector (J7) Slimline D connector (J8) Power connector 2 (J34) Mini-SAS HD connector...
  • Page 86 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-78 4 x 3.5" built-in-drive backplane (BOM: 03024MBJ) Mini-SAS HD connector Backplane signal cable (PORT A/J3) connector (INNER HDD BP/J1) Power connector (INNER HDD PWR/J2) Rear-Drive Backplanes ⚫ 2 x 2.5" drive backplane Figure 5-79 2 x 2.5"...
  • Page 87 FusionServer 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-80 2 x 3.5" drive backplane (BOM: 03022HYE) Mini-SAS HD connector Indicator signal cable (REAR PORT/J3) connector (REAR BP/J24) Power connector (BP PWR/J1) ⚫ 4 x 2.5" drive backplane Figure 5-81 4 x 2.5"...
  • Page 88: Product Specifications

    FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical Specifications Component Specifications Form factor 2U rack server ® Chipset Intel C622 Processor Supports one or two processors.
  • Page 89 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Component Specifications RDIMM and LRDIMM support − The DDR4 memory modules of different types − (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
  • Page 90 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Component Specifications Do not use the M.2 SSD as the cache. ⚫ ⚫ Supports hot swap of SAS/SATA/NVMe U.2 drives. NOTE The NVMe drives support: Surprise hot swap if the VMD function is enabled and the ⚫...
  • Page 91 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Component Specifications even damage the NIC. ⚫ Forcibly powering off a server will cause intermittent NC-SI disconnection and disable the WOL function of the LOM ports. To restore the NC-SI connection, refresh the iBMC WebUI.
  • Page 92: Environmental Specifications

    FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Component Specifications You are not advised to install the operating system on the USB storage media. Video card An SM750 video chip with 32 MB display memory is integrated on the mainboard. The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors.
  • Page 93 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications NOTE The highest operating temperature varies depending on the server configuration. For details, see A.3 Operating Temperature Limitations . Relative humidity (RH, ⚫ Operating humidity: 8% to 90%...
  • Page 94: Physical Specifications

    FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications LWAd: 5.64 Bels − LpAm: 42.2 dBA − Operating: ⚫ LWAd: 6.08 Bels − LpAm: 46.8 dBA − NOTE The noise generated during operation varies depending on the server configuration, load, and ambient temperature.
  • Page 95 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Item Description NOTE ⚫ See Figure 6-1 for methods in measuring physical dimensions of the chassis. ⚫ Methods measuring 3.5" and 2.5" drive chassis are the same. The 3.5" drive chassis is used as an example.
  • Page 96 FusionServer 2288H V5 Server Technical White Paper 6 Product Specifications Item Description 30.5 kg (67.24 lb) ⚫ Packaging materials: 5 kg (11.02 lb) Energy consumption The power consumption parameters vary with server configurations, including the configurations complying with energy-related products (ErP) requirements. Use the Power Calculator to obtain specific information.
  • Page 97: Software And Hardware Compatibility

    FusionServer 2288H V5 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
  • Page 98: Safety Instructions

    FusionServer 2288H V5 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
  • Page 99 FusionServer 2288H V5 Server Technical White Paper 8 Safety Instructions ⚫ Do not carry the weight that is over the maximum load per person allowed by local laws or regulations. Before moving or installing equipment, check the maximum equipment weight and arrange required personnel.
  • Page 100 FusionServer 2288H V5 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of the device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the equipment from falling down and causing personal injury or damage to the equipment.
  • Page 101: Maintenance And Warranty

    FusionServer 2288H V5 Server Technical White Paper 8 Safety Instructions equipment being transported is always kept upright. Take necessary precautions to prevent collisions, corrosion, package damage, damp conditions and pollution. ⚫ Transport the equipment in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe GPUs and SSDs) separately.
  • Page 102: System Management

    FusionServer 2288H V5 Server Technical White Paper 9 System Management System Management The server uses the next-generation Intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with IPMI 2.0 and provides highly reliable hardware monitoring and management.
  • Page 103 FusionServer 2288H V5 Server Technical White Paper 9 System Management Specifications Description Setting of boot device Supports out-of-band configuration for the boot device. Alarm management Supports alarm management and reports alarms using the SNMP trap, SMTP, and syslog service to ensure 24/7 operating.
  • Page 104: Certifications

    FusionServer 2288H V5 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
  • Page 105 FusionServer 2288H V5 Server Technical White Paper 10 Certifications Country/Region Certification Standards EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS:...
  • Page 106: A Appendix

    FusionServer 2288H V5 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
  • Page 107 FusionServer 2288H V5 Server Technical White Paper A Appendix A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server Model For details, see A.4 Nameplate . Device names Power Supply Requirements Vendor Information Authentication ID A.1.1.2 Certificate Figure A-3 Sample certificate Issue 11 (2023-04-30) Copyright ©...
  • Page 108 FusionServer 2288H V5 Server Technical White Paper A Appendix Table A-2 Certificate description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate No. Table A-3 Certificate No. Description Description The value for this digit is P, which is fixed.
  • Page 109 FusionServer 2288H V5 Server Technical White Paper A Appendix Description Letters A to H indicate 10:00 to 17:00. ⚫ ⚫ Letters J to N indicate 18:00 to 22:00. Letters P to Q indicate 23:00 to 24:00. ⚫ Indicates the serial number (two digits).
  • Page 110 FusionServer 2288H V5 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Safety Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
  • Page 111 FusionServer 2288H V5 Server Technical White Paper A Appendix Figure A-8 Example SN Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
  • Page 112 FusionServer 2288H V5 Server Technical White Paper A Appendix Configuratio Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) configuration V100s,...
  • Page 113 FusionServer 2288H V5 Server Technical White Paper A Appendix Configuratio Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) A100, and...
  • Page 114 FusionServer 2288H V5 Server Technical White Paper A Appendix Configuratio Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) drive 24 x 2.5-inch ⚫...
  • Page 115 FusionServer 2288H V5 Server Technical White Paper A Appendix A.5 RAS Features The server supports a variety of Reliability, Availability, and Serviceability (RAS) features. You can configure these features for better performance. For details about how to configure these features, see the...
  • Page 116 FusionServer 2288H V5 Server Technical White Paper A Appendix Module Feature Description improve system reliability. System Core Disable For FRB Isolates a faulty CPU core during startup (Fault Resilient Boot) to improve system reliability and availability. Corrupt Data Containment Marks the memory storage unit when a...
  • Page 117 FusionServer 2288H V5 Server Technical White Paper A Appendix A.6 Sensor List Sensor Description Component Inlet Temp Air inlet temperature Left mounting ear Outlet Temp Air outlet temperature Mainboard PCH Temp PCH bridge temperature Mainboard CPUN Core Rem CPU core temperature...
  • Page 118 FusionServer 2288H V5 Server Technical White Paper A Appendix Sensor Description Component ranges from 1 to 2. CPUN DDR VDDQ2 1.2 V DIMM voltage Mainboard N indicates the CPU number. The value ranges from 1 to 2. CPUN VSA CPU VSA voltage...
  • Page 119 FusionServer 2288H V5 Server Technical White Paper A Appendix Sensor Description Component temperature PowerN PSU input power PSUN N indicates the PSU number. The value is 1 or PCH Status PCH chip fault diagnosis Mainboard health status CPUN QPI Link...
  • Page 120 FusionServer 2288H V5 Server Technical White Paper A Appendix Sensor Description Component PwrOk Sig. Drop Voltage dip status Mainboard PwrOn TimeOut Power-on timeout Mainboard PwrCap Status Power capping status Mainboard HDD Backplane Entity presence Drive backplane HDD BP Status Drive backplane health...
  • Page 121 FusionServer 2288H V5 Server Technical White Paper A Appendix Sensor Description Component ranges from 0 to 24 or from 36 to 47. LOM P1 Link Down LOM P2 Link Down LOM P3 Link Down LOM P4 Link Down PCIe RAID$ Temp...
  • Page 122 FusionServer 2288H V5 Server Technical White Paper A Appendix Sensor Description Component FPGA# EnvTemp FPGA card operating PCIe card temperature FPGA# DDR Temp FPGA card memory PCIe card temperature FPGA# Power FPGA card power PCIe card FPGA# OP Temp FPGA card optical...
  • Page 123: B Glossary

    FusionServer 2288H V5 Server Technical White Paper B Glossary Glossary B.1 A-E ejector lever A part on the panel of a device used to facilitate installation or removal of the device. Ethernet A baseband local area network (LAN) architecture developed by Xerox Corporation by partnering with Intel and DEC.
  • Page 124 FusionServer 2288H V5 Server Technical White Paper B Glossary B.3 K-O A hardware device that provides public keyboard, video and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
  • Page 125 FusionServer 2288H V5 Server Technical White Paper B Glossary B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet or chassis. 1 U = 44.45 mm UltraPath A point-to-point processor interconnect developed by Interconnect (UPI) Intel.
  • Page 126: C Acronyms And Abbreviations

    FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System calendar day Conformite Europeenne...
  • Page 127 FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations DDR3 Double Data Rate 3 DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory...
  • Page 128 FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
  • Page 129 FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface C.4 P-T PCIe Peripheral Component Interconnect Express power distribution unit physical layer...
  • Page 130 FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Serial Attached Small Computer System Interface SATA Serial Advanced Technology Attachment...
  • Page 131 FusionServer 2288H V5 Server Technical White Paper C Acronyms and Abbreviations TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc. Universal Serial Bus VCCI...

Table of Contents