Download Print this page

Sealey ADB3000 Instructions page 2

Air dryer/blower

Advertisement

DO NOT stand the air dryer/blower where it may be knocked over or off a surface, or where the lead may cause a person to trip.
DO NOT use the air dryer/blower outdoors.
When not in use place the air dryer/blower in its original box, or cover the unit to protect from dust, and store in a safe, dry, childproof
location.
2. INTRODUCTION
Robust, composite housing and carefully balanced and fully guarded blade drum provide quiet and safe operation. Housing design provides
three outlet positions from horizontal to vertical, allowing precise direction of airflow for cooling or drying. Handle incorporates cable storage.
Suitable for use in industrial, commercial, agricultural and automotive workshops.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . ADB300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADB3000
Speeds: . . . . . . . . . . . . . . . . . . . . . . . . . 1275rpm . . . . . . . . . . . . . . . . . . . . . 940/1210/1370rpm
Maximum Airflow: . . . . . . . . . . . . . . . . . 10mtr³/min (356cfm) . . . . . . . . . . . . 81³/min (2860cfm)
Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . 230V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Current: . . . . . . . . . . . . . . . . . . . . . . . . . 0.5A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5A
Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . 3.3kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16.6kg
4. OPERATION
WARNING! Ensure you read, understand and apply safety instructions before using the blower.
4.1.
Lift the blower by the handle on the main body and manoeuvre it into desired position. Use in any of the 3 positions illustrated below. Ensure that
there isn't anything in front of the blower that may be disturbed when the blower is switched on.
4.2.
Check that the switch situated in the recess in the rear grille of the blower is set to "0"/OFF. Uncoil the power lead from its stowage
position and plug into the mains power supply. Ensure that the power lead is not stretched or positioned in such a way as to cause a hazard.
4.3.
Turn the blower on by switching to "I"/ON. If a greater air flow is required, turn the switch to the "II" or "III" setting (ADB3000 only).
4.4.
When finished using the blower, ensure the switch is set to the "0"/OFF position and disconnect it from the mains power.
4.5.
Rewind the lead around the lugs on the carrying handle.
4.6.
When not in use, place the blower in its original box or otherwise protect it from dust, and store in a safe, dry, childproof location.
5. MAINTENANCE
WARNING! Ensure the blower is disconnected from the mains power supply before attempting any of the following.
5.1.
Use a soft, slightly dampened cloth to clean the body of the blower. Do not splash with water and never allow water to drip onto the motor
housing. DO NOT use solvents or other chemicals to clean the blower.
5.2.
If it becomes necessary to clean the blades or the inside of the body, remove the rear grille (the opposite side to the motor) by undoing the
retaining screws. Wipe with a slightly damp cloth only. Re-fit the grille and fix in place using the retaining screws.
5.3.
Should the motor, speed control box or the power lead require service or maintenance, contact your local service agent.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into
approved containers and dispose of the product and the fluids according to local regulations.
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and
Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling information.
NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Environmental Protection
WEEE Regulations
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
www.sealey.co.uk
01284 757500
sales@sealey.co.uk
01284 703534
ADB300, ADB3000 Issue: 3 (L) - 17/02/17