Name
Installation and operating manual
Owner's manual
Connecting pipe
assembly
WARNING
Appliance shall be stored in a well -ventilated area where the room size corresponds to the
room area as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than 4m .
Appliance shall not be installed in an unvertilated space, if that space is smaller than 4m .
For R290 refrigerant models, the minimum room size needed:
<=9000Btu/h units: 13m
>9000Btu/h and <=12000Btu/h units: 17m
>12000Btu/h and <=18000Btu/h units: 26m
>18000Btu/h and <=24000Btu/h units: 35m
Shape
Liquid side
Gas side
2
2
2
2
6.35( 1/4 i n)
9.52( 3/8in)
9.52( 3/8in)
12.7( 1/2in)
16( 5/8in)
Quantity
1
Parts you must purc hase.
Consult the dealer about
the pipe size.
2