Initialization Status Errors
Code
Flash Sequence
E 07
Repeating series of seven
LED flashes, separated by
a pause
E 08
Repeating series of eight
LED flashes, separated by
a pause
E 09
Repeating series of nine
LED flashes, separated by
a pause
E 10
LED flashes on and off;
POWER
LED remains off
MSG
E 11
LED flashes once;
POWER
LED flashes once
E 12
LED flashes once;
POWER
LED flashes twice
E 13
LED flashes once;
POWER
LED flashes three times
E 14
LED flashes once;
POWER
LED flashes four times
E 15
LED flashes once;
POWER
LED flashes five times
E 16
LED flashes once;
POWER
LED flashes six times
E 17
LED flashes once;
POWER
LED flashes seven times
Only the V860DL AND ACD2204 tuner appear on the on-screen display.
Cause
ROM verification failure
MSG
Faulty RAM, ROM, EEPROM, or
MSG
POST failure (this is a hardware
failure)
Dead battery or the memory has
MSG
not been initialized; occurs if the
battery fails to keep the RAM alive
during power-down; causes
set-top to be disconnected
Invalid serial number
Invalid unit address
MSG
POST failed
MSG
Sys_boot initialization failure
MSG
System startup failure
MSG
TSI structure is corrupted
MSG
Bad flash number specified for
MSG
Initiate Flash Platform
Bad platform validation
MSG
step number
Diagnostics
Remedy
Power cycle the set-top; if
repetitive, return for repair
Return the set-top
for repair
Return the set-top for
repair; requires factory
initialization message
Not used at this time
Return the set-top for
repair; requires a unit
creation message
Not used at this time
Power cycle the set-top; if
repetitive, return for repair
Power cycle the set-top; if
repetitive, return for repair
Power cycle the set-top; if
repetitive, return for repair
Error logged, ignore
Error logged, ignore