Bosch PST 6101.321 Technical Information page 72

Timer and i/o level
Table of Contents

Advertisement

1070 080 056-101 (99.09) GB
PST 6101.321 / PSI 6101.321
Current
Example :
Counter starting section
%
Counter stepper section
Count (wear) factor
Prewarning
*1
Max. no. of dressing operations
Example: sequence without reset "Electrodes have been replaced" and w/o
Figure 25: Example: electrodes replaced
NOTE
The response of the weld timer (stop or continued operation) to the reaching of the max.
number of welds (end of stepper) is programmed in the Basic Setup, window Global Step-
per-Setup.
NOTE
It is also possible to confirm with the BOS-5000 software that electrodes have been re-
placed.
2.0
10.0
1.0
*1
1.0
*1
stop at end of stepper
Reset "Electrodes have been replaced"
Electrical connection
*1 Stepper Curve
Tipdress Curve
Counts (wear)
9.0
End of Stepper
10.0
Prewarning
Stop at
End of stepper
Reset "Electrodes have
been replaced"
Counts (wear)
10.0
9.0
Prewarning
End of Stepper
no sequence stop
7-29