During Operation Safety Loading the Mix Tank Hopper with Bulk Salt Filling the Batch Tank with Water Using the VSI Spray Control App Information Display Agitating a Batch of Brine Pumping Out Brine to Storage Tanks Filling Trucks with Brine From Storage Tanks...
Page 4
Electrical System Safety Brine Maker System Maintenance Service the In-Line Filter Screen Inspecting the Hoses Cleaning Cleaning the Salt Hopper Cleaning the BatchTank Flushing the System Conditioning the Machine Storage Storage Safety Storing the Machine Removing the Machine from Storage Troubleshooting...
A digital version of this manual that can be accessed Safety Instructions on the VSI Spray Control app (“Getting Started/FAQ” button on the Profile” tab). ● Read the Operator’s Manual. If service, parts, or additional information is needed ●...
To begin using the machine, you must first download Detailed Installation the VSI Spray Control App from either the Apple App store or Google Play store onto your phone or tablet. Instructions 4. Connect to Machine Via 1. Electrical Outlet...
prompted with either a successful connection or a failed connection. The sprayer will store the credentials for the last ten (10) WiFi connections entered. 5. Connect Machine to WiFi The machine uses WiFi to search for new firmware releases that may come out to increase performance and reliability of the system.
Product Overview 1. Truck Fill Camlock 8. Digital Salinity Module 14. Aux 2 Additive Valve 2. Air Purge 15. Aux 1 Water Valve 3. Filter 9. Digital Salinity Sensor 16. Eductor Nozzle 4. Truck Fill Valve 10. Agitation Valve 17. Salt Hopper/ Mix Tank 5.
Page 9
The digital salinity module box houses the circuit board for connecting to the VSI Spray Control App and transmitting the digital salinity reading. 3. Filter 9. Digital Salinity Sensor Each machine is equipped with a filter right before the inlet to the pump.
It can also be accessories are available for use with the sprayer to used as a secondary additive storage tank if providing enhance and expand its capabilities. Contact VSI for water to the brine maker in a different manner. See further information.
● Become familiar with the safe operation of the ● Use the correct chemical for the job. equipment, operator controls, and safety signs. ● Follow the chemical manufacturer’s ● Shut off the pump, wait for all movement to instructions for safely applying the chemical. stop, and allow the machine to cool before Do not exceed the recommended system adjusting, servicing, cleaning, or storing it.
Sprayer Control Box Light Modes The computer inside the control box will display different light modes depending on the operation status of the machine. Common light modes include the following: Status LED Indicator Mode and Meaning Flashing magenta Control box is receiving a firmware update. It is normal for the light to appear solid for a short period of time and flash at different rates while the firmware update is being downloaded.
The DETAILS tab contains the serial number of the machine and the last reset reason. When connected to the machine, the VSI Spray Select the drop down arrow in the upper right concern Control app will display the concentration of salt in the to toggle to a BrineMixer .
Plumbing to Auxiliary Tanks Auxiliary 3 Valve- Brine The valve situated at the far right of the manifold A manifold bank of three (3) valves are provided with (when facing the plumbing) must be used for the each machine. This manifold system can be storage tank of the brine.
Understanding Valve Positions shows the Agitation Valve and Tank Valve in the open positions. Proper valve positioning is vital to the machine working correctly for each given task. Suction-Side Valves vs. Pressure-Side Valves Suction-side valves: Any valves on the machine that are entering the lower portion of the pump housing.
Page 16
Set the valves in AUXILIARY 1 WATER FILL MODE VALVE POSITION when needing to add water to the batch tank. The figure below shows the Tank Valve and Aux 1 Water Valve in the open positions. Auxiliary 3 Brine Truck Fill Mode Valve Position Set the valves to AUXILIARY 3 BRINE TRUCK FILL MODE VALVE POSITION when you are ready to draw...
Using the VSI Spray Control App Information Display Load bulk salt into the mix tank hopper using a loader and bucket. Align loader bucket towards the center of the hopper to avoid spilling salt over the hopper 1. Open the VSI Spray Control app.
POSITION (see earlier in the manual). 3. Turn on the pump switch. 4. Continue to add salt into the hopper until the correct salinity of 23.3% is reached. Use the VSI Spray app to monitor the salinity level. A manual hydrometer is also included.
After you are finished filling trucks with liquid you can 1. Connect the brine maker to a sprayer via the 2” fill use the Air Purge to prevent spilling liquid from the hose line with camlocks. hoses and valves after each movement of liquid. If desired, connect an air compressor to the air-purge 2.
Washing the Brine Maker Note: Use only clean water when cleaning the system. Wash the inside of the salt hopper and batch tank with clean water. Maintenance Failure to properly maintain the machine could result in premature failure of machine systems, causing possible harm to you or bystanders.
● Shut off the machine, wait for all movement to ● If the machine requires a major repair or you stop, and allow the machine to cool before need technical help, contact an authorized VSI adjusting, servicing, cleaning, or storing it. distributor.
3. If the screen is clogged, clean the screen. 4. Inspect the gasket. Replace if it is worn or has cracks. 5. Reinstall the screen and in-line filter cap. Inspecting the Hoses Service Interval: Every 200 hours 4. Clean the inside of the tank and remove any debris or rocks.
5. Check the agitation nozzles to ensure that all holes Storage Safety are spraying correctly. Shut off the engine, wait for all movement to stop, and 6. Allow all water to circulate. allow the machine to cool before adjusting, servicing, cleaning, or storing it.
7. Check that the app is operating on your connected device. Troubleshooting Problem Possible Cause Corrective Action The pump does not prime. 1. The Tank Valve is closed. 1. Open the Tank Valve. 2. A hose is cracked or leaks. 2.