Summary of Contents for STIEBEL ELTRON SNO 5 Plus GB

  • Page 1 Operation and installation SNO 5 Plus GB / SNO 10 Plus GB Small water heater (non-pressur- ised)
  • Page 2: Table Of Contents

    Table of contents 1 Special information ........... 3 2 General information..........3 Test mark ............3 Units of measurement ........3 Symbols in this document ........ 3 3 Safety................ 3 Intended use ............ 3 Structure of the warning notices....... 3 Safety instructions ..........
  • Page 3: Special Information

    Special information Units of measurement Special information All measurements are given in mm unless stated otherwise. – The appliance may be used by children over Symbols in this document 3 years of age and persons with reduced physical, sensory or mental capabilities or a Symbol Meaning lack of experience and expertise, provided...
  • Page 4: Safety Instructions

    Failure to observe this information will result in death or A non-pressurised tap must be used for open vented operation serious injury of the appliance. Stiebel Eltron offers a wide range of suitable WARNING Failure to observe this information may result in death or taps.
  • Page 5: Appliance Installation

    Commissioning (qualified contractors) u Match up the colour coding on the tap water connections and the appliance: – R.h. side blue = "Cold water inlet" – L.h. side red = "DHW outlet" u Secure the water connections from the tap to the appliance. D0000107420 Appliance installation u Mark out the holes for drilling using the installation tem-...
  • Page 6: Setting A Permanent Temperature Limit

    Operation WARNING Electrocution Ensure that the appliance is connected to the earth conductor. NOTICE Overvoltage The voltage specified on the type plate must match the mains power supply. u Establish the electrical connection by plugging in the stand- ard plug or by a permanent connection. The following electrical connections are permissible: D0000107424 | CO 1 Temperature selector...
  • Page 7 Installation Template...
  • Page 8 305 mm...
  • Page 10 Installation Template...
  • Page 11: Opening The Appliance

    Remove the two screws behind the temperature selector. protective pipe u Pull off the limiting ring. SNO 5 Plus GB u When replacing the temperature controller, guide the tem- perature sensor into its protective pipe. u Secure the temperature sensor in place below the earthed plug.
  • Page 12: Troubleshooting (Installers)

    Drain the appliance (see chapter "Maintenance (qualified contractors) / Draining the appliance"). 13 Specification 13.1 Dimensions and connections 5 litre appliance D0000107470 13.3 Wiring diagram 1/N/PE | 220 – 240 V SNO 5 Plus GB D0000105875 D0000107434 Appliance Height Appliance Width...
  • Page 13: Energy Consumption Data

    The product data complies with EU regulations relating to the Energy data directive on the ecodesign of energy related products (ErP). Standby energy consumption/ 0.17 0,27 24 h at 65 °C SNO 5 Plus GB SNO 10 Plus GB Energy efficiency class 204979 204984 Versions Manufacturer...
  • Page 14 | SNO 5 - 10 Plus GB www.stiebel-eltron.com...