6
Piping Connection
1
2
8
9
5
Figure 5.
Principal Piping Connection
Position Explanation
1
Upper condensate outlet
2
Lower condensate outlet
3
Hot water tap
4
Solar sensor
5
Drain barrel
8
Temperature and pressure valve
9
Anode rod
10
Hot water outlet
Warning! If a solar energy solution is installed, the water temperature can rise very quickly. Preventive
measures must be taken for the piping connections.
Note! If the water pressure is too high (above 5 bars), a pressure reducer should be installed at the water
inlet. This is the installer´s responsibility.
In principle, arrange the water pipes connections as illustrated in the above figure example.
Note! A safety valve should be installed at the water inlet of the unit.
6.1
Water inlet and outlet pipes
The specification of the water inlet or outlet (internal) thread is DN20 (RC3/4"). Pipes must be heat-resistant and
durable.
12 – Installation, Service and User Manual VMGFK202
3
10
4
14
15
27
16
17
13
12
Position Explanation
12
Valve stem
13
Expansion vessel (if required)
14
Solar water inlet
15
Solar water outlet
16
Drain pipe
17
Mixing valve
27
Water inlet