E - 3 - SHUTTING DOWN THE APPLIANCE:
- Close bottle cock and/or gas pressure reducing valve
handle.
tHIS aPPLIaNCe IS eQUIPPeD WItH aN atMoSPHere
aNaLYSer DeVICe WHICH aUtoMatICaLLY tUrNS
oFF tHe aPPLIaNCe SHoULD tHe rooM CoNtaIN
too HIGH a CarBoN DIoXIDe PerCeNtaGe (Co
IN tHIS CaSe, tHoroUGHLY VeNtILate tHe rooM,
otHerWISe tHe aPPLIaNCe WILL Not reLIGHt.
F - REMOvING OR REPLACING THE GAS BOTTLE
- Check that gas bottle cock and/or pressure reducing
valve handle is in the closed position.
- open appliance rear plate (fig. 4 item B) and remove the
bottle from its housing, taking care not to pull or bend the
hose.
- Disconnect pressure reducing valve from gas bottle.
- Install the new gas bottle and carry out a leak test as
described under paragraphs D-1 and D-2.
G - STORAGE - SERvICING
1) Appliance
When it is not used, the appliance should remain open
and be stored in a dust-free place.
Defects
the burner does not light up
the burner misfires or turns off
Unstable blowing flames
the pilot burner does not light up
Warranty Period
Years
).
2
Defects / Remedies
2
- remove stains with soapy water, when the appliance is
cold. Wipe off with a cloth.
- Do not use abrasives which might damage the paintwork.
- For heavy repairs, please call your vendor.
- the appliance must be periodically checked, more
particularly concerning condition of the connecting hose.
2) Hose between the pressure reducing valve and the
appliance
- Periodically check hose for condition and replace it if it
displays ageing signs or cracks.
- the hose must be replaced by a new one of same length
and equivalent quality.
- the hose must be replaced in compliance with the
above-mentioned periodicity for the respective countries.
- In France, if the expiry date printed on the hose is
reached, it must be replaced by a hose compliant with
the XP D 36-112 Standard.
- Comply with installation indications provided with these
new assemblies to be 0.50 m long, and with the
procedure described under paragraph C - 2.
- If your appliance is to remain unused for a long period,
disconnect gas bottle.
3) Electric supply cable (IR 5000 Turbo model)
- all damaged cables must be replaced by the
manufacturer, its after-sales service or a similarly-
qualified person, to avoid danger.
Probable causes / remedies
- Poor gas feed
- Pressure reducing valve inoperative
- Check for gas level in bottle
- Check for gas level in bottle
- Check hose connection
- Call technical support
- New bottle. allow to operate, the defect will disappear
- Call technical support
- Pilot burner clogged
- Call technical support.
9
GB
Need help?
Do you have a question about the IR 5000 and is the answer not in the manual?