Page 1
DK Series REV 005A May, 2023 VERTICAL WINDLASSES MODELS AVAILABLE IN LH/RH VERSION, WITH AND WITHOUT DRUM DK 3024 DC DK 3524 DC DK 4000 AC DK 5500 AC DK HYDRO *Other languages available by scanning the QR code on the *EN - INSTALLATION AND USER'S MANUAL back of this manual or on the label on the product.
Page 3
6.0 - Important cautions 6.1 - Clutch use 6.2 - Drum use 6.3 - Troubleshooting 7 - Maintenance 8 - Product disposal 9 - List of components 10 - Spare parts 11 - Dimensions QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
1 - Information about the product DK Series READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THE PRODUCT. IF IN DOUBT, CONTACT YOUR QUICK ® DEALER. QUICK ® RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
Page 6
® • Control from control board • Diverter from panel • Waterproof push-button panel • Foot-operated switch • Hydraulic-magnetic circuit breaker • Anchor chain counter • Control system via RRC radio QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
3 - Introduction BEFORE USING THE PRODUCT, PLEASE READ THIS USER’S MANUAL CAREFULLY. IF IN DOUBT, PLEASE CONSULT YOUR QUICK® DEALER. 3.0 - Important notes This manual features Warning and/or Caution symbols that are important for safety. Please follow the instructions provided.
The roller height; a positive chain tilt with respect to the deck level up to 5° is permitted, the negative tilt must not interfere with the windlass base 5° 40cm (16”) QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
HYDRAULIC MOTOR: Connect the pipes coming from the distribution valve to the two hydraulic motor flanges. (see connection diagram on page 12) 4.2 - Motor gearbox position 90° Depending on the type of motor gearbox, a 45° rotation every 45° or 90° is possible. 90° 45° 45° 90° QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 10
MOTOR Black Brown Blue BATTERY FUSE 2A (24V) HYDRAULIC-MAGNETIC CIRCUIT BREAKER (see table on page 4) REMOTE SWITCH CONTACT BOX (24V) L = L1 + L2 + L3 + L4 QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 11
Black Brown Blue FUSE 2A (24V) HYDRAULIC-MAGNETIC CIRCUIT BREAKER (see table on page 4) REMOTE SWITCH CONTACT BOX (24V) L = L1 + L2 + L3 + L4 + L5 + L6 QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 12
5.2 - Example of connection of 220V single-phase DK 3000W MULTI-PURPOSE PUSH-BUTTON PANEL WINDLASS generic image FOOT-OPERATED SWITCHES SENSOR SENSOR TERMINAL BOARD CABLES ~ MOTOR EC-BOX CONTROLLER BATTERY 24V POWER SUPPLY 230 V EARTH QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 13
5.3 - Example of connection of 400V DK 4000W - 5500W with EC-BOX MULTI-PURPOSE PUSH-BUTTON PANEL WINDLASS generic image FOOT-OPERATED SWITCHES SENSOR SENSOR TERMINAL BOARD CABLES ~ MOTOR EC-BOX CONTROLLER BATTERY 24V EARTH QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 14
5 - Wiring diagram 5.4 - Example of connection of 400V DK 4000W - 5500W with INVERTER MULTI-PURPOSE PUSH-BUTTON PANEL WINDLASS generic image FOOT-OPERATED SWITCHES ~ THREE-PHASE POWER SUPPLY FUSE INVERTER 3 200...690 Vac QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 15
DK Series 5 - Wiring diagram 5.4 - Example of hydraulic system connection WINDLASS generic image DISTRIBUTOR VALVE PRESSURE INPUT QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
• DO NOT operate the windlass by using the electrical power when the handle is inserted in the drum or into the gypsy cover. • Quick® recommends using a suitable power fuse/thermal-magnetic/hydraulic-magnetic protection for the motor used, to protect the motor from overheating or short circuits.
If the hydraulic magnetic switch, has tripped, reset it and wait a few minutes before weighing anchor once again. If, after a number of attempts, the windlass is still blocked, we suggest to move the boat to release the anchor. QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Separate the products for disposal in accordance with the regulations in force in your area or return the product to the seller when purchasing a new equivalent product. Local regulations may impose severe penalties for the improper disposal of this product. QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
SCREW BASE COVER SERIES “DK” SCREW WINDLASS BASE SERIES “DK” STUD BASE INSERT O-RING “DK” BASE INSERT SCREW BASE INSERT FLANGE SENSOR COVER SENSOR GROWER WASHER SCREW TG110 GEARBOX WASHER SCREW MOTOR QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 20
OSP MOTOR GEARBOX 3500W 24V RY6/DK6 FVSSR3524DK0A00 18 A OSP MOTOR GEARBOX 4000W 230/400V DK6 FVSSR40TR000A00 OSP MOTOR GEARBOX 5500W 230/400V DK6 FVSSR55TR000A00 OSP HYDRO MOTOR GEARBOX 4000W DK6 FVSSRHYTR000A00 OSP GEARBOX 4000W WINDLASS DK6/RY6/TB6 FVSSMR400000A00 QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 21
DK Series NOTES QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 22
590 ( 23 409 (16 DUKE SERIES 3500 590 ( 23 409 (16 DUKE SERIES 4000/5500 598 (23 612 (24 4000W = 5500W = 409 (16 DUKE SERIES HYDRO 406 ( 15 QUICK DKSeries INSTALLATION AND USER’S MANUAL - REV005A...
Page 24
DK Series REV 005A Product serial number QUICK S.p.A. - Via Piangipane, 120/A - 48124 Piangipane (RAVENNA) - ITALY ® Tel. +39.0544.415061 - Fax +39.0544.415047 - www.quickitaly.com - quick@quickitaly.com...
Need help?
Do you have a question about the DK Series and is the answer not in the manual?
Questions and answers