Table 10: Overview of maintenance work
Maintenance interval
First check after at least 6
months; interval can be
extended to 12 months (in sports
facilities and leisure parks)
Every 4000 hours, at least once a
year
Every 8000 hours, at least every
3 years
Every 16,000 hours, at least
every 5 years
54 of 154
7 Servicing/Maintenance
WARNING
Insufficient stability
Risk of crushing hands and feet!
▷ During assembly/dismantling, secure the pump (set)/pump parts against tilting
or tipping over.
WARNING
Corrosion on the pump set
Risk of injury from solid matter in the fluid handled!
▷ If persons come into contact with the fluid handled during pump operation
(e.g. in sports facilities and leisure parks), check the pump set for corrosion
regularly and adhere to the maintenance interval specified.
NOTE
Special regulations apply to repair work on explosion-proof pump sets.
Modifications or alteration of the pump sets can affect explosion protection and
are only permitted after consultation with the manufacturer.
A regular maintenance schedule will help avoid expensive repairs and contribute to
trouble-free, reliable operation of the pump (set) with a minimum of maintenance
expenditure and work.
NOTE
All maintenance work, service work and installation work can be carried out by KSB
Service or authorized workshops. Find your contact in the attached Addresses
booklet or visit https://www.ksb.com/en-global/contact.
Never use force when dismantling and reassembling the pump set.
7.2 Servicing/inspection
KSB recommends the following regular maintenance schedule:
Maintenance work
Visually inspect for corrosion.
Measure the insulation resistance.
Check the cable bundle.
Check the ground conductor.
Check the sensors.
Check the mechanical seal leakage.
Change the lubricant.
Lubricate the rolling element bearings.
General overhaul
On pump sets with sacrificial anodes, the sacrificial anodes must initially be checked
after 6 months. If necessary, the sacrificial anodes must be replaced. If the sacrificial
anodes show little wear, the maintenance interval can be extended to 12 months.
Amacan P
For details see ...
(ð Section 7.3.6, Page 60)
(ð Section 7.2.1.1, Page 55)
(ð Section 7.3.3, Page 58)
(ð Section 7.3.4, Page 58)
(ð Section 7.2.1.2, Page 55)
(ð Section 7.3.5, Page 59)
(ð Section 7.4.2, Page 62)
Need help?
Do you have a question about the Amacan P 700-470 and is the answer not in the manual?