Download Print this page

Specifications - Fujitsu ARUX12TLAV2 Operation Manual

Indoor unit duct type
Hide thumbs Also See for ARUX12TLAV2:

Advertisement

Fog comes out of the outdoor unit:
● During Cooling operation, a thin mist may be seen emitted from the
indoor unit. This results from the sudden Cooling of room air by the air
emitted from the air conditioner, resulting in condensation and misting.
Steam comes out of the indoor unit:
● During Heating operation, the outdoor unit's fan may stop, and steam
may be seen rising from the unit. This is due to the Automatic defrosting
operation. (Refer to "OPERATING TIPS")
Water is produced from the outdoor unit:
● During Heating operation, water may be produced from the outdoor unit
due to the Automatic defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn't operate at all:
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation different from the priority state?
(Refer to "OPERATING TIPS")
● Is it in standby state? (Refer to "OPERATING TIPS")
The operation mode cannot be changed:
● Are you trying to change to an operation different from the priority condi-
tions? (Refer to "OPERATING TIPS")
Poor Cooling (or Heating) performance:
● Did you adjust the temperature setting correctly?
● Is the air fi lter dirty? (Refer to "CLEANING AND CARE")
● Are the air conditioner's inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the fan speed set to low?
Temperature does not fall down well.
● Temperature may not fall down depending on the room conditions. (While
high humidity or the room temperature is high.) (Refer to "OPERATING
TIPS")
Set the temperature lower than the room temperature and use it.
In the following situations stop operation immediately
and get in touch with authorized service personnel.
● The problem cannot be solved even when the troubleshooting checks
have been performed.
● The Filter indicator lamp (red) is blinking very fast (when the IR receiver
unit is connected).
● The Wired remote controller or Simple remote controller indicate "Er"
(when either controller is connected).
● It has burning smell.
● For details on marking the blinking lamps, please refer to the Manual of
"IR receiver unit" or "Wired remote controller".

SPECIFICATIONS

ARUX12
Model
TLAV2
Power source
Available voltage
range
Cooling
Btu/h
12,000
capacity
(kW)
(3.5)
Heating
Btu/h
13,500
capacity
(kW)
(4.0)
Dimensions and weight
in
Height
(mm)
in
Width
(mm)
in
Depth
(mm)
lbs
100
Weight
(kg)
(45)
ARUX30
Model
TLAV2
Power source
Available voltage
range
Cooling
Btu/h
30,000
capacity
(kW)
(8.8)
Heating
Btu/h
34,000
capacity
(kW)
(10.0)
Dimensions and weight
in
Height
(mm)
in
Width
(mm)
in
Depth
(mm)
lbs
Weight
(kg)
● Standard static pressure : 0.5 in WG (125 Pa)
ARUX18
ARUX24
TLAV2
TLAV2
208/230 V ~ 60 Hz
187 to 253 V
18,000
24,000
(5.3)
(7.0)
20,000
27,000
(5.9)
(7.9)
43.0
(1,092)
17.5
(444)
21.0
(533)
102
(46)
ARUX36
ARUX48
ARUX60
TLAV2
TLAV2
TLAV2
208/230 V ~ 60 Hz
187 to 253 V
36,000
48,000
60,000
(10.6)
(14.1)
(17.6)
40,000
54,000
67,000
(11.7)
(15.8)
(19.6)
48.0
58.75
(1,219)
(1,492)
21.0
24.5
(533)
(622)
21.0
21.75
(533)
(552)
126
172
(57)
(78)
181
(82)
En-4

Advertisement

loading