Table 2. Fuse Size Selection
NOTE
NOTE
Table 3. Electrode Selection Table
Electrode/Diameter
Pure Tungsten
(Green Band)
0.010 in. (0.25mm)
0.020 in. (0.51mm)
0.040 in. (1.02mm)
1/16 in. (1.59mm)
3/32 in. (2.38mm)
1/8 in. (3.18mm)
5/32 in. (3.97mm)
3/16 in. (4.76mm)
1/4 in. (6.35mm)
2% Thorium Alloyed Tungsten
(Red Band)
0.010 in. (0.25mm)
0.020 in. (0.51mm)
0.040 in. (1.02mm)
1/16 in. (1.59mm)
3/32 in. (2.38mm)
1/8 in. (3.18mm)
5/32 in. (3.97mm)
3/16 in. (4.76mm)
1/4 in. (6.35mm)
SETUP FOR OPERATION
Input Power/Input Voltage
Single-Phase
208-230 VAC
115 VAC
Continuous output on 115VAC/20 Amp circuit breaker for fuse: 92 Amps/
13 Vdc (TIG), 51 Amps/23 Vdc (Stick).
Fuse size is based on not more than 200 percent of the rated input
amperage of the welding power source (Based on Article 630, National
Electrical Code).
DC-Argon Electrode
Negative/Straight Polarity
1-15
5-20
15-80
70-150
125-225
225-360
360-450
450-720
720-950
1-25
15-40
25-85
50-160
135-235
250-400
400-500
500-750
750-1,000
Fuse Size (Amperes)
Model 130GTS
30
25
Amperage Range
DC-Argon Electrode
Positive/ReversePolarity
34
Model 130S
30
30
—
—
—
10-20
15-20
25-40
40-55
55-80
80-125
—
—
—
10-20
15-30
25-40
40-55
55-80
80-125
MANUAL 0-2620
Need help?
Do you have a question about the THERMAL ARC 130 GTS & S CC/TIG and is the answer not in the manual?