S A F E G U A R D S IMPORTANT INFORMATION CONT'D EXAMPLE OF ANTENNA GROUNDING ACCORDING TO NATIONAL ELECTRICAL CODE INSTRUCTIONS CONTAINED IN ARTICLE 810 - "RADIO AND TELEVISION EQUIPMENT" GROUND CLAMP SERVICE ENTRANCE CONDUCTORS SERVICE ENTRANCE EQUIPMENT POWER SERVICE GROUNDING ELECTRODE SYSTEM (e.g.
Page 4
I N T R O & S P E C S INTRODUCTION TO UHF CONVERSION SINGLE CHANNEL CONVERTER UHF IN TEST MONITOR VHF OUT AURAL 120VA 60HZ 10W 600VA MAX...
Page 5
FIELD ALIGNMENT XUV FIELD CHANNEL CONVERSION If both input and output channels are to be changed, perform the input channel conversion WITHOUT changing the output channel. Then, reset the PLL dip switches one more time and align the output filter Sweep alignment of the input filters is recommended when the desired UHF signal is within 3 channels of other UHF signals.
BENCH ALIGNMENT VIDEO AUDIO XFMR VHF Output Output Filter POWER Output SUPPLY Amplifier BOARD SWEEP GENERATOR OUTPUT INPUT Detector Test Point 2 VHF Input Oscillator Test Point 1...10 Input Test Point 3 UHF Output PLL Board Filter UHF Input...
Page 7
BENCH ALIGNMENT VIDEO AUDIO Output Filter POWER SUPPLY BOARD XFMR SWEEP GENERATOR Test Point 2 VHF Input Oscillator Output Test Point Amplifier 1...10 Test Point 3 PLL Board UHF Output OUTPUT INPUT Detector UHF Input Input Filter...