Download Print this page
Sealey CH4200.V2 Instructions
Sealey CH4200.V2 Instructions

Sealey CH4200.V2 Instructions

Cabinet gas heater 4.2kw

Advertisement

Quick Links

Thank you for purchasing a Sealey Heater. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to instruction manual
1. SAFETY
1.1.
GENERAL SAFETY
WARNING! Only to be used with Butane gas - DO NOT use Propane gas with this heater.
WARNING! Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Store Butane gas cylinders in accordance with the regulations applicable.
Ensure that nothing stands or passes in front of the heater. Mandatory minimum distance from the heater is 1 metre.
Position the heater so that it is facing towards the middle of a room and away from furnishings, furniture, fabrics and walls etc.
Ensure that the heater is sited in a well ventilated area. A ventilation opening must run to the outside of the premises where the heater
is to be operated.
Use the supplied pressure regulator only.
If the smell of gas is detected, or a leak suspected, turn the gas valve off immediately. DO NOT turn it back on again until the leak has
been detected. DO NOT disconnect the regulator. Ensure there are no naked flames or ignition sources present and DO NOT switch any
electrical equipment or switches on or off. Open windows and doors to increase ventilation. Check all the gas connections. To check for
leaks, the use of a foamy soap solution or leak detector spray is recommended. Brush the fittings with the solution or apply detector spray
onto them and gently open the regulator tap. A leak will form bubbles in the solution. If a leak is found, turn the tap off and DO NOT use
the heater until it has been inspected and repaired by a competent gas engineer.
Ensure that the heater is correctly turned off when not in use.
Take care placing the heater on a smooth surface, where it could easily be moved or pivot on its castors, if pushed accidently.
The burner and airways of the heater must be kept clean. Frequent cleaning may be needed, due to build up of carpet fibres etc.
DO NOT use the heater until all connections have been leak tested.
DO NOT use the heater if damaged. Take immediate action to repair or replace damaged parts. Use an authorised service agent only.
DO NOT allow untrained persons to ignite or operate the heater.
DO NOT allow children to operate or to play in the area around the heater.
DO NOT use a naked flame to try and ignite the heater, or change the gas cylinder whilst using a naked light.
DO NOT use the heater where there is flammable material present - either liquids, solids or gases (e.g. - garages where petrol vapour may
be present, or laboratories, workshops etc. where highly flammable material may be present).
DO NOT use multiple portable heaters in a room.
DO NOT attempt to move the heater whilst it is working, or until it has cooled down.
DO NOT twist the flexible gas supply hose.
DO NOT leave the heater unattended at any time whilst in use.
DO NOT stand too close to the heater as the high temperature could burn or ignite clothing.
DO NOT cover or place items to dry over the heater, even after it has been turned off, as it will remain hot for some time afterwards.
DO NOT use in leisure vehicles such as caravans or motorhomes.
DO NOT use in high rise flats.
DO NOT use in wet or damp areas, such as bathrooms etc.
DO NOT use in bedrooms.
DO NOT use in basements or below ground level.
DO NOT remove the front grille from the heater, it is there to protect from the risk of fire, or injury from burns. IT DOES NOT HOWEVER
GIVE FULL PROTECTION TO YOUNG CHILDREN OR THE INFIRM. Use additional guards where necessary, to provide additional
protection, especially if children or animals are present.
Keep the heater clean and in a good working order. When not in use, store in a safe, dry, childproof location. After a period of storage, the
heater should be examined by a qualified gas engineer, prior to use.
NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
2. INTRODUCTION
Ceramic plaque cabinet heater ideal for office or home use. Accepts 15kg Butane bottle (not included) which fits into the rear of the unit. Features
piezoelectric ignition, removing the need for batteries. Three heat output settings ranging from 1.55 to 4.2kW (5,288 to 14,330Btu/hr). Safety
features fitted include a flame failure device, anti-tilt switch and oxygen depletion system. Supplied with hose and regulator.
© Jack Sealey limited
InSTRUCTIOnS FOR:
CABINET GAS HEATER 4.2KW
CH4200.V2
MOdEl nO:
Original Language Version
CH4200.V2 Issue: 1 - 12/06/15

Advertisement

loading

Summary of Contents for Sealey CH4200.V2

  • Page 1 CH4200.V2 MOdEl nO: Thank you for purchasing a Sealey Heater. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 Model No: ........
  • Page 3 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.