JAI GO-2400M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Hide thumbs Also See for GO-2400M-PGE:
Table of Contents

Advertisement

Quick Links

User Manual
GO-2400M-PGE GO-2400C-PGE
GO-2401M-PGE GO-2401C-PGE
Thank you for purchasing this product.
Be sure to read this documentation before use.
This documentation includes important safety precautions and instructions on how to operate the unit. Be sure to read this documentation to ensure
proper operation.
The contents of this documentation are subject to change without notice for the purpose of improvement.
© 2023 JAI
CMOS Digital Progressive Scan
Monochrome and Color Camera with GigE Interface
GO-510x-PGE_Manual_Ver.3.0_2023/04/28
Document Version: 3.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GO-2400M-PGE and is the answer not in the manual?

Questions and answers

Summary of Contents for JAI GO-2400M-PGE

  • Page 1 User Manual GO-2400M-PGE GO-2400C-PGE GO-2401M-PGE GO-2401C-PGE CMOS Digital Progressive Scan Monochrome and Color Camera with GigE Interface Document Version: 3.0 GO-510x-PGE_Manual_Ver.3.0_2023/04/28 Thank you for purchasing this product. Be sure to read this documentation before use. This documentation includes important safety precautions and instructions on how to operate the unit. Be sure to read this documentation to ensure proper operation.
  • Page 2: Table Of Contents

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Table of Contents Table of Contents Table of Contents About Technical Note Notice/Warranty Notice Warranty Certifications CE Compliance Warning Supplement Supplement Usage Precautions Notes on Cable Configurations Notes on LAN Cable Connection Notes on Attaching the Lens Phenomena Specific to CMOS Image Sensors Notes on Exportation...
  • Page 3 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Table of Contents Characteristics of the Recommended Circuits for Opto OUT Preparation Step 1: Install the Software (First Time Only) Step 2: Connect Devices ① Lens ② Direct Mounting (or Use MP-43 Tripod Adapter Plate) ③...
  • Page 4 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Table of Contents Trigger Control Shortest Repetition Period for Triggers Event Control Gain Control LUT (Lookup Table) Gamma Function Line Status ShadingCorrection To Use the Shading Correction Function Binning Function ROI (Region of Interest) Settings Sensor Multi ROI Function Video Send Mode Overlap Multi ROI...
  • Page 5 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Table of Contents EventControl AnalogControl LUTControl SequencerControl Digital IO Control PulseGenerators TransportLayerControl ActionControl UserSetControl ChunkDataControl JAICustomControlALC JAICustomControlBlemish JAICustomControlShading JAICustomOverlapMultiROI JAICustomControlMultiROI JAICustomCounterAndTimerControl JAICustomControlMisc Miscellaneous Troubleshooting Power Supply and Connections Image Display Settings and Operations Specifications Package contents Optional accessories (not supplied)
  • Page 6: About Technical Note

    Table of Contents About Technical Note Some additional technical information is provided on the JAI website as Technical Notes. In this manual, if a technical note is available for a particular topic, the above icon is shown. Please refer to the following URL for Technical notes.
  • Page 7: Notice/Warranty

    The material contained in this manual consists of information that is proprietary to JAI Ltd., Japan, and may only be used by the purchasers of the product. JAI Ltd., Japan makes no warranty for the use of its product and assumes no responsibility for any errors which may appear or for damages resulting from the use of the information contained herein.
  • Page 8: Warning

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Notice/Warranty connected. Consult the dealer or an experienced radio/TV technician for help. Warning Changes or modifications to this unit not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment. 제조년월은...
  • Page 9: Supplement

    Pollution by Electronic Information Products “, known as “China RoHS“. The table shows contained Hazardous Substances in this camera. mark shows that the environment-friendly use period of contained Hazardous Substances is 15 years. Applicable Models: GO-2400M-PGE and GO-2401M-PGE 重 要 注 意 事 项 有毒,有害物质或元素名称及含量表 根据中华人民共和国信息产业部『电子信息产品污染控制管理办法』, 本产品《 有毒,有害物质或...
  • Page 10: Supplement

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Notice/Warranty Supplement The following statement is related to the regulation on “Measures for the Administration of the Control of Pollution by Electronic Information Products “, known as “China RoHS“. The table shows contained Hazardous Substances in this camera.
  • Page 11: Usage Precautions

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Usage Precautions Usage Precautions Notes on Cable Configurations The presence of lighting equipment and television receivers nearby may result in video noise. In such cases, change the cable configurations or placement. Notes on LAN Cable Connection Secure the locking screws on the connector manually, and do not use a driver.
  • Page 12: Phenomena Specific To Cmos Image Sensors

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Usage Precautions Phenomena Specific to CMOS Image Sensors The following phenomena are known to occur on cameras equipped with CMOS image sensors. These do not indicate malfunctions. Aliasing: When shooting straight lines, stripes, and similar patterns, vertical aliasing (zigzag distortion) may appear on the monitor.
  • Page 13: Features

    This camera is capable of high frame rates (see below table) for full 5.1-megapixel output. Even faster frame rates can be achieved when binning is utilized (Monochrome models only) or when a smaller ROI (region of interest) is specified. Model Max Frame Rate (8-bit) GO-2400M-PGE, GO-2400C-PGE 48.8 fps GO-2401M-PGE, GO-2401C-PGE 41.0 fps - 13 -...
  • Page 14 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Features ALC (Automatic Level Control) Function Combine the automatic gain control and automatic exposure control functions to allow handling of changes in various brightnesses. Variety of Pre-Process Functions LUT (lookup table): For programmable control over gamma and contrast. Gamma correction: Gamma can be set to 0.45, 0.60, or 1.0 (off).
  • Page 15: Parts Identification

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification Parts Identification ① Lens Mount (C-Mount) ② RJ-45 Connector ③ POWER/TRIG LED ④ LINK LED ⑤ ACT LED ⑥ DC IN/TRIG Connector (6-Pin Round) ⑦ Mounting Holes (M3, 3mm depth) ① Lens Mount (C-Mount) Mount a C-mount lens, microscope adapter, etc.
  • Page 16: ② Rj-45 Connector

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification ② RJ-45 Connector Connect a Gigabit Ethernet compatible LAN cable (Category 5e or higher, Category 6 recommended) here. GigE Vision Interface Pin No. Input/Output Signal In/Out MX1+ (DA+) In/Out MX1– (DA–) In/Out MX2+ (DB+) In/Out...
  • Page 17: ④ Link Led

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification ④ LINK LED Indicates whether the GigE network connection is established or not. Status The network link is not established (or in progress). Lit green 1000Base-T link is established. ⑤ ACT LED Indicates the GigE network status.
  • Page 18: ⑥ Dc In/Trig Connector (6-Pin Round)

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification ⑥ DC IN/TRIG Connector (6-Pin Round) Connect the cable for a power supply (optional) or for DC IN / trigger IN here. Camera Side: HR10A-7R-6PB (73) (Hirose Electric or equivalent) Cable Side: HR10A-7P-6S (Plug) (Hirose Electric or equivalent) Pin No.
  • Page 19: Recommended Circuit Diagram (Reference Examples)

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification Recommended Circuit Diagram (Reference Examples) Related Setting Items: Digital IO Control OPTO-In Circuit Characteristics Recommended External Input Circuit Diagram Recommended External Output Circuit Diagram (Reference Example) - 19 -...
  • Page 20: Characteristics Of The Recommended Circuits For Opto Out

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Parts Identification Characteristics of the Recommended Circuits for Opto OUT OUTPUT LINE RESPONSE TIME GO-2401M/C-PGE User Power (Vcc) R1、 R4 = 330 Ω PULL_UP 3.3V 5.0V TDR (Time Delay Rise) (μs) 0.78 0.82 2.65 RT (Rise Time) (μs)
  • Page 21: Preparation

    Read this section to learn how the camera connects to devices and accessories. The preparation process is described below. Step 1: Install the Software (First Time Only) Install the software for configuring and controlling the camera (eBUS SDK for JAI) on the computer. Step 2: Connect Devices Connect the lens, LAN cable, AC adapter, computer, and other devices.
  • Page 22: Step 1: Install The Software (First Time Only)

    When using the camera for the first time, install the software for configuring and controlling the camera (eBUS SDK for JAI) on the computer. Note: When you install eBUS SDK for JAI, eBUS Player for JAI will also be installed. 1. Download the eBUS SDK for JAI from the JAI website (https://www.jai.com/support-software/jai-...
  • Page 23: ① Lens

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation ① Lens C-mount lenses with lens mount protrusions of 9 mm or less can be attached. The diagonal of the camera’s CMOS image sensor is 13.4 mm, which is larger than the 11 mm size of standard 2/3-inch lenses.
  • Page 24: ③ Lan Cable

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation ③ LAN Cable Connect a LAN cable to the RJ-45 connector. Use a LAN cable that is Category 5e or higher (Category 6 recommended). When supplying power via PoE, connect to a PoE-compatible switching hub or a PoE- compatible network card.
  • Page 25: Step 3: Verify Camera Operation

    Step 4: Verify the Connection between the Camera and PC Verify whether the camera is properly recognized via Control Tool. 1. Launch eBUS Player for JAI eBUS Player for JAI startup screen appears. - 25 -...
  • Page 26 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation 2. Select the camera you want to configure. Click the Select / Connect button. 3. The connected camera is listed. Please select one camera and click OK. - 26 -...
  • Page 27 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation 4. Check that the settings of the selected camera are displayed. 5. Click the Device control button. The screen shown below will be displayed. In this window, you can adjust various settings of the camera. This completes the procedure for verifying whether the camera is properly recognized and whether control and settings configuration are possible.
  • Page 28: Step 5: Change The Camera Settings

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Step 5: Change the Camera Settings This section explains how to change settings by describing the procedure for changing the output format as an example. Configure the Output Format Configure the size, position, and pixel format of the images to be acquired. The factory settings are as follows.
  • Page 29: Configure Exposure And External Trigger Settings

    Packet Size setting to a value less than 1500 in the eBUS Player for JAI (under Transport Layer Control / Stream Channel Selector, or set your NIC or switch to support “Jumbo Frames.” This setting is typically found in the Advanced Adapter Settings for the NIC or switch which can be accessed through the Device Manager on your PC.
  • Page 30: Control Via External Triggers

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Control via External Triggers When Controlling the Exposure Time Using Specified Exposure Times Configure the settings as follows. Item Setting Value / Selectable Range Trigger Selector Frame Start - Trigger Mode - Trigger Source - Trigger Activation Rising Edge, Falling Edge...
  • Page 31 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation 1. Set Exposure Mode to Timed. (Timed is the default setting.) 2. Specify the exposure time in Exposure Time. The setting value for the exposure time can only be changed when Exposure Auto is set to Off. If Exposure Auto is set to Continuous, temporarily set it to Off before changing the exposure time.
  • Page 32 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation When Controlling the Exposure Time using the Pulse Width of the Trigger Input Signal Configure the settings as follows. Item Setting Value / Selectable Range Trigger Selector Frame Start - Trigger Mode - Trigger Source - Trigger Activation Level High, Level Low...
  • Page 33: Control Without External Triggers

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Control Without External Triggers When Controlling the Exposure Time Using Specified Exposure Times Configure the settings as follows. Item Setting Value / Selectable Range Trigger Selector Frame Start - Trigger Mode Exposure Mode Timed (Control via Exposure Time) GO-2400MC-PGE: 38 ~ 7999900 (μs)
  • Page 34 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation 1. Set Exposure Mode to Timed. (Timed is the default setting.) 2. Specify the exposure time in Exposure Time. The setting value for the exposure time can only be changed when Exposure Auto is set to Off. If Exposure Auto is set to Continuous, temporarily set it to Off before changing the exposure time.
  • Page 35: Step 6: Adjust The Image Quality

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Step 6: Adjust the Image Quality Display the camera image and adjust the image quality. Display the Image Display the image captured by the camera. When you click the Play button, the camera image appears in the right area.
  • Page 36 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation For the color model, Analog All (master gain), Digital Red (digital R gain), and DigitalBlue (digital B gain) can be configured individually. 2. Set Gain. The master gain (AnalogAll) can be set x1 (0dB) to x16 (+24dB) against the analog base gain.
  • Page 37: Adjusting The White Balance

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Adjusting the White Balance Adjust the white balance using R and B gain. The white balance can also be adjusted automatically. Note: The White Balance function is supported only on the color models. Manual White Balance Adjustment 1.
  • Page 38: Adjust The Black Level

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation Adjust the Black Level 1. Expand Analog Control, and select the black level you want to configure in Black Level Selector. For the monochrome model, only Digital All (master black) can be configured. For the color model, Digital All (master black), Digital Red (digital R), and Digital Blue (digital B) can be configured individually.
  • Page 39: To Save User Settings

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation To Save User Settings 1. Stop image acquisition. 2. Expand UserSetControl and select the save destination (UserSet1 to UserSet3) in UserSetSelector. Note: The factory default setting values are stored in Default and cannot be overwritten. Caution: Settings can only be saved when image acquisition on the camera is stopped.
  • Page 40: To Load User Settings

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Preparation To Load User Settings 1. Stop image acquisition. User settings can only be loaded when image capture on the camera is stopped. 2. Select the settings to load (UserSet1 to UserSet3) in UserSetSelector. 3.
  • Page 41: Main Functions

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Main Functions This chapter describes the camera's main functions. Basic Function Matrix The combinations of settings for the basic functions that can be used together are as follows. Binning Frame Sensor Overlap Trigger...
  • Page 42: Gpio (Digital Input/Output Settings)

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions GPIO (Digital Input/Output Settings) Related Setting Items: Digital IO Control The camera is equipped with GPIO (general-purpose input/output) functions for generating and using combinations of triggers and other necessary signals within the camera and of signals output from the camera to the system such as those used for lighting equipment control.
  • Page 43: Acquisition Control

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Output destination Pulse Generator Trigger Selector Line Selector Source Selector Signal Time Acquisition Acquisition Frame Transfer Line Line NAND NAND NAND NAND Pulse Generator Stamp Start Stop Start Start 1 In 1 1 In 2 2 In 1 2 In 2...
  • Page 44: Maximum Frame Rate

    Note: The Frame Rate Calculator, which calculates the maximum frame rate, is available for download from the product page on the JAI website (www.jai.com). Maximum Frame Rate Period Formula During continuous operation (Frame Start trigger is Off or Exposure Mode is Off) Maximum frame rate of sensor output SensorFR = 1/((Height_s + 40)×Hperiod)
  • Page 45 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Interface FR 920 × 1000000 / (Height × Width × Pack value) Maximum frame rate FR_TrOloff Min(Sensor FR, Interface FR) Exposure time possible within frames MaxOverlapTime_TrOloff (1 / FR_TrOloff) (1 / Sensor FR) Exposure time outside of frame interval NonOverlapExposureTime_TrOloff ExposureTime...
  • Page 46 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Exposure time outside of frame interval NonOverlapExposureTime_TrOlrd ExposureTime MaxOverlapTime_TrOlrd However, NonOverlapExposureTime_TrOlrd calculation results that are 0 or below will be considered as 0. For TriggerWidth, the trigger pulse is equivalent to ExposureTime. Maximum frame rate FR_TrOlrd 1 / {(1 / FR_TrOloff)
  • Page 47: Exposure Mode

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Notes: *Height_s: Line scanned by the sensor. **Height_g, Width_g: Height and width of output streams. ***12-bit binning is not supported. Caution: Although the maximum frame rate value is determined by the GigE bandwidth range, when ROI is configured, the frame rate cannot exceed the sensor output's allowable frame rate value.
  • Page 48: Trigger Control

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Trigger Control Related Setting Items: AcquisitionControl The camera allows the following controls to be performed via external trigger signals. Trigger Selector Description Start exposure in response to the external trigger signal input. Select this to perform FrameStart exposure control using external triggers.
  • Page 49 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions When Exposure Mode is Timed Example: When Trigger Source is set to Line 5 - Optical In 1 and OptIn Filter Selector is set to 10 μs Trigger Overlap: OFF GO-2400- GO-2401- GO-2400-...
  • Page 50 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions When Exposure Mode is Trigger Width Example: When Trigger Source is set to Line 5 - Optical In 1 and OptIn Filter Selector is set to 10 μs Trigger Overlap: Off GO-2400- GO-2401- GO-2400-...
  • Page 51: Event Control

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Event Control Related Setting Items: EventControl “Event control” is a function that uses GVCP (GigE Vision Control Protocol) to output points of change in the camera’s internal signal as event occurrence information or “event messages.” When this information is output, the camera’s internal timestamp counter value is added.
  • Page 52 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions To Use the Event Control Function Configure the settings as follows. Item Setting Value / Selectable Range Description AcquisitionTrigger FrameStart FrameEnd FVAL Start FVAL End ExposureStart Event Selector ExposureEnd Select the event for which to send notifications. Line2 RisingEdge Line2 FallingEdge Line3 RisingEdge...
  • Page 53: Gain Control

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Gain Control Related Setting Items: AnalogControl Analog All can be used for gain control for both the monochrome and color camera. Analog All (master gain) uses the sensor's internal gain function and consists of analog gain + digital gain. Analog gain is used for lower gain, and analog gain + digital gain is used when the gain becomes high.
  • Page 54: Lut (Lookup Table)

    You can specify the output curve using 256 setting points (indexes). To Use the LUT Function Configure the settings as follows. Setting Value / Item Description Selectable Range JAI LUT Use LUT. Mode Selector Color Model: Red, (Color Select the LUT channel to control. Green, Blue...
  • Page 55: Gamma Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions LUT Values LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate LUT values between the index points. Gamma Function Related Setting Items: AnalogControl The Gamma function corrects the output signals from the camera beforehand (reverse correction), taking into consideration the light-emitting properties of the monitor display.
  • Page 56: Line Status

    Setting Value / Selectable Range Description Gamma 0.45, 0.60, 1.0 (Off) Select the gamma correction value. JAI LUT Mode Gamma Use gamma. Note: You can use the LUT function to configure a curve with more detailed points. For details, “LUT (Lookup Table)”.
  • Page 57: Shadingcorrection

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions ShadingCorrection Related Setting Items: JAICustomControlShading The shading correction is a function that corrects non-uniformity (i.e., shading) in the amount of light generated by the lens and lighting equipment. Using this function allows correction even if top, bottom, left, and right shading is not symmetrical in relation to the center of the screen (H, V).
  • Page 58: To Use The Shading Correction Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions ColorShading (Color models only) R-channel and B-channel properties are adjusted by using the G-channel shading properties as a reference. Cautions: Proper correction is not possible under the following conditions. If an area with a brightness level that is more than 30% less than the reference level exists within the screen If the brightness level is saturated in parts or all of the screen If the area in the screen with the highest brightness level is 300 LSB or less (during 10-bit...
  • Page 59: Binning Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Binning Function Related Setting Items: ImageFormatControl The binning function allows you to combine the signal values of clusters of adjacent pixels on the sensor to create improved virtual pixels. Using the function results in images with lower pixel resolution and higher sensitivity.
  • Page 60: Roi (Region Of Interest) Settings

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions ROI (Region of Interest) Settings Related Setting Items: ImageFormatControl The ROI (region of interest) function allows you to output images by specifying the areas to scan. ROI Settings Specify the area to scan by specifying width, height, and horizontal/vertical offset values under Image Format Control.
  • Page 61: Sensor Multi Roi Function

    ROI function outputs the specified regions in a compressed state. You can increase the frame rate due to the reduced scanning time for the compressed areas. However, you cannot make the line frequency faster by compressing in the horizontal direction. Note: This function is supported only on GO-2400M-PGE and GO-2400C-PGE. Restrictions The specified areas cannot overlap.
  • Page 62 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Configuration Configure each area so that they do not overlap. Both the horizontal and vertical settings must be configured as even values. Horizontal ROI conditions ROIOffsetH1 + ROIWidth1 < ROIOffsetH2 ROIOffsetH2 + ROIWidth2 <...
  • Page 63 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Reference: Areas corresponding to the HorizontalEnable and VerticalEnable settings of each setting Index 1 Index 2 Index 3 Index 4 Number of Enabled Enabled Area Hori Vert Hori Vert Hori Vert Hori Vert...
  • Page 64 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Frame Rate Calculation Formula FR = line frequency ÷ (ROIHeight1 + ROIHeight2 + ROIHeight3 + ROIHeight4 +vertical invalid line) There are two types of line frequencies. SensorReadout 10 bit, camera output 8 bit: 12.4445 KHz SensorReadout 12 bit, camera output 10 bit: 24.2425 KHz Vertical invalid line: 40 (fixed) Differences when Multi ROI Overlap is On or Off...
  • Page 65: Video Send Mode

    On this camera, the areas can overlap, and a separate frame will be output for each area. Specify the areas by specifying width, height, and horizontal/vertical offset values for each index under JAI Custom Control MultiROI. Note: Please refer to Sensor Multi ROI Function...
  • Page 66: Sequence Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Sequence Function Related Setting Items: SequencerControl The Sequencer function lets you define up to 128 preset combinations of exposure time, gain, ROI, and other settings which can be stepped through each time a trigger is received. This is particularly useful for quickly capturing multiple exposures of objects under inspection to adjust for areas or components with significantly different levels of reflectance.
  • Page 67 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Sequencer Repetition This parameter applies to Trigger Sequencer patterns which include an index whose Sequencer ROI Next Index is set to OFF. When the index whose Sequencer ROI Next Index is set to OFF is finished executing, the value of Sequencer Repetition (range = 1 ~ 255) is decremented internally.
  • Page 68: Command Sequencer Mode

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Command Sequencer Mode This mode allows the user to vary the “pattern” of the sequence in response to external factors. Changes in the sequence can be initiated manually or in a programmatic fashion as the result of data from sensors/controllers or from the analysis of previous images.
  • Page 69 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Command Sequencer Examples User-defined Indexes (up to 128) Index structure for Command Sequencer - 69 -...
  • Page 70: Delayed Readout

    Set Gain Auto or Exposure Auto or both to Continuous mode. Configure the minimum value, maximum value, etc. for AGC and ASC under JAI Custom Control ALC. The target video levels for AGC and ASC are configured in ALC Reference. For example, when ALC Reference is set to 100%, video levels will be maintained at 100% for AGC and ASC.
  • Page 71: Detailed Settings For Gain Auto (Automatic Gain Level Control)

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Automatic Gain Level Control Set Gain to Continuous. Detailed Settings for Gain Auto (Automatic Gain Level Control) When Gain Auto is set to Continuous, you can configure the conditions for automatic adjustment in detail.
  • Page 72: Ptp (Precision Time Protocol) Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions PTP (Precision Time Protocol) Function Related Setting Items: TransportLayerControl How to Use Action Commands in GigE Vision Cameras Note: This function is supported only on GO-2400MC-PGE. The camera can work as the slave for Precision Time Protocol defined in IEEE 1588. When the IEEE 1588 master clock exists in the network where the camera is connected, this function synchronizes the camera to the time of the master clock.
  • Page 73: Counter And Timer Control Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Counter and Timer Control Function Related Setting Items: JAICustomCounterAndTimerControl Note: This camera supports only the counter function. The counter function counts up change points in the camera’s internal signals using the camera’s internal counter and reads that information from the host side.
  • Page 74: To Use The Counter Function

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions To Use the Counter Function Configure the settings as follows. Three counters can be configured (Counter 0 to 2). Setting Value / Selectable Item Description Range Counter 0 ~ 2 Counter 0 ~ 2 Select the counter.
  • Page 75: Video Process Bypass Mode

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Main Functions Video Process Bypass Mode The video process bypass mode is a function that bypasses internal video processing on the camera. When bypass is enabled, the sensor output and camera output data can be set to the same bit width. Operation using 12-bit outputs must be performed in bypass mode.
  • Page 76: Chunk Data Function

    The camera has non-volatile memory for users to store data. Refer to the technical note “Storing Data in On-Camera Flash Memory” for more information. Note: JAI strongly recommends saving images to the PC or other storage location because the non-volatile flash memory may not have enough memory size to store large data.
  • Page 77: Settings List

    Display/configure information related to the device. Device Control Item Setting Range Default Description Device Vendor Name “JAI Corporation” Display the manufacturer name. Device Model Name Display the model name. Device Manufacturer Info "See the possibilities" Display the manufacturer information. Device Version Display the hardware version.
  • Page 78 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Image Format Setting Range Default Description Control Item 0 ~ 1920 (960)* Offset X Set the horizontal offset. *When Binning = 2, the value in "( )" is applicable. 0 ~ 1215 (607)* Offset Y Set the vertical offset.
  • Page 79: Acquisitioncontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List AcquisitionControl Configure image acquisition settings. Note: Settings that can only be configured when image acquisition on the camera is stopped. Acquisition Setting Default Description Control Item Range Select the image acquisition mode. Single Frame Acquisition Mode Multi Frame...
  • Page 80 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Acquisition Setting Default Description Control Item Range Rising Edge Falling Edge Trigger Select the polarity of the trigger signal (i.e., location of signal at which trigger is Rising Edge Activation applied).
  • Page 81: Eventcontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List EventControl Related Topic: Event Control Configure event control settings. Event Control Item Setting Range Default Description AcquisitionTrigger FrameStart FrameEnd FVAL Start FVAL End ExposureStart ExposureEnd Opt Out1 Rising Edge Line2 RisingEdge Event Selector Opt Out2 Rising Edge AcquisitionTrigger...
  • Page 82: Analogcontrol

    Balance White Off. Auto Once Continuous Color models only Related Topic: Adjusting the White Balance Set the gamma value. 0.45 Gamma 0.60 0.45 Related Topic: Gamma Function JAI LUT Mode Gamma Select the JAI LUT mode. - 82 -...
  • Page 83: Lutcontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List LUTControl Related Topic: LUT (Lookup Table) Configure LUT settings. Note: Settings that can only be configured when image acquisition on the camera is stopped. LUT Control Item Setting Range Default Description LUT Selector Green...
  • Page 84 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Sequencer Setting Default Description Control Item Range Set the next index to be displayed for the selected Sequencer Index. (Enabled Sequencer Set Next 1 ~ 128 only for Trigger Sequencer.) Sequencer Width 16 ~ 1936 1936...
  • Page 85: Digital Io Control

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Digital IO Control Related Topic: GPIO (Digital Input/Output Settings) Configure settings for digital input/output. Digital IO Control Setting Default Description Item Range Line2 - Opt Out Line3 - Opt Out 2 Line5 - Opt In 1 Time Stamp Line2 - Opt...
  • Page 86: Pulsegenerators

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Digital IO Control Setting Default Description Item Range Line Format Opto Coupled Display the current I/F type. Line Status All 0x00 Display status of input signal. User Output 0 User Output Selector User Output 0 Set the user output signal.
  • Page 87 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Setting Control Default Description Range Item Pulse Set the start point of the Low interval in milliseconds. When the counter reaches this Generator 0.002222 ~ 33.3333 value, the output will be 0. The setting range varies depending on the Clock Pre-scaler End Point 2330.166666 value.
  • Page 88: Transportlayercontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List TransportLayerControl Display information on transport layer control. Transport Layer Control Setting Range Default Description Item Payload Size 2354176 Display the payload size. GevVersionMajor Display the GigE version. GevVersionMinor Display the GigE version. False GevDeviceModeIsBigEndian True...
  • Page 89 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Transport Layer Control Setting Range Default Description Item GevTimestampTickFrequency 1000000000 Display the timestamp frequency. GevTimestampControlLatch Latch the timestamp value. GevTimestampControlReset Reset the timestamp value. GevTimestamp Value Display the timestamp value. GevCCP (Control Channel Privilege) Control Access Display the control channel privilege.
  • Page 90: Actioncontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List Supported GigEVision Options: Link Local Address configuration, DHCP configuration, Persistent IP configuration, Stream Channel Source Socket, Message Channel Source Socket, Command Concatenation, Write Mem, Packet Resend, Event,Event Data, Pending Ack, Action, Extended Status Codes, Discovery Ack Delay, Discovery Ack Delay Writable, Test Data, Manifest Table, CCP Application Socket, Link Speed, Heartbeat Disable, Serial Number, StandardIDMode, IEEE1588Support, UniconditionalAction, ScheduledAction, PrimaryApplicationSwitchover, ExtendedStatusCodesVersion2_0, UserDefinedName, SingleLink, MultiLink, StaticLAG, DynamicLAG, PAUSEFrameReception, PAUSEFrameGeneration,...
  • Page 91: Usersetcontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List UserSetControl Related Topic: Step 7: Save the Settings Configure user settings. Note: Settings that can only be configured when image acquisition on the camera is stopped. Setting User Set Control Item Default Description Range...
  • Page 92: Chunkdatacontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List ChunkDataControl Related Topic: Chunk Data Function Configure chunk control settings. Note: Settings that can only be configured when image acquisition on the camera is stopped. Chunk Data Control Setting Range Default Description Item...
  • Page 93: Jaicustomcontrolalc

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List JAICustomControlALC Related Topic: ALC (Automatic Level Control) Function Configure JAI ALC settings. These settings are also used for AGC (auto gain control). Control Setting Range Default Description Item ALC Reference 10 ~ 100 Set the target level for ALC.
  • Page 94: Jaicustomcontrolblemish

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List JAICustomControlBlemish Configure settings for JAI white blemish correction. Blemish Setting Control Default Description Range Item False Blemish Enable True Enable/disable blemish correction. True Blemish Detect Execute blemish detection. Blemish Detect 0 ~ 100 Set the blemish detection threshold.
  • Page 95: Jaicustomoverlapmultiroi

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List JAICustomOverlapMultiROI Related Topic: Sensor Multi ROI Function Configure settings for JAI sensor multi ROI. Note: Settings that can only be configured when image acquisition on the camera is stopped. Multi ROI Item Setting Range Default...
  • Page 96: Jaicustomcontrolmultiroi

    Related Topic: Sensor Multi ROI Function Configure settings for JAI sensor multi ROI. Notes: This function is supported only on GO-2400M-PGE and GO-2400C-PGE. Settings that can only be configured when image acquisition on the camera is stopped. Setting Multi ROI Item...
  • Page 97: Jaicustomcounterandtimercontrol

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List JAICustomCounterAndTimerControl Related Topic: Counter and Timer Control Function Configure counter settings. (This camera only supports counter functions.) Counter and Timer Control Setting Default Description Item Range Counter 0 ~ 2 Counter 0 ~ 2 Select the counter.
  • Page 98: Jaicustomcontrolmisc

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Settings List JAICustomControlMisc Configure settings for other JAI functions. Note: Settings that can only be configured when image acquisition on the camera is stopped. Misc. Item Setting Range Default Description Video Process Bypass Enable / disable video process bypass mode.
  • Page 99: Miscellaneous

    Miscellaneous Miscellaneous Troubleshooting Check the following before requesting help. If the problem persists, contact your local JAI distributor. Power Supply and Connections Issue: The POWER/TRIG LED remains lit amber and does not turn green, even after power is supplied to the camera.
  • Page 100: Specifications

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous Specifications Specifications Description Scanning System Progressive scan, 1 tap Synchronization Internal Interface 1000Base-T Ethernet (GigE Vision 1.1), IEEE 802.3af Mono: Type 1/1.2 Monochrome CMOS Image sensor Color: Type 1/1.2 Bayer color CMOS Image Size (Effective Image) 11.3mm x 7.13mm (13.4mm diagonal) Pixel Size...
  • Page 101 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous Specifications Description Full pixel: 1936 × 1216 (H x V) Width 16 ~ 1936, 16 pixels/step OFFSET X 0 ~ 1920, 16 pixels/step 1 ~ 1216 lines Height 1 line/step (Mono), 2 line/step (Color) 0 ~ 1215 lines, 2 line/step OFFSET Y 1 line/step (Mono), 2 line/step (Color)
  • Page 102 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous Specifications Description Manual Adjustment 0 dB to +24 dB 1 step = x0.01 (0.005 dB to 0.08 dB) (varies by Range setting value) Auto Gain Off / Continuous WB Gain* R / B: - 7 dB ~ + 15 dB、1 Step = 0.1 dB Gain Adjustment WB Area* 16 (4 ×...
  • Page 103: Package Contents

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous Package contents Camera body (1) Sensor protection cap (1) Dear Customer (sheet) (1) Optional accessories (not supplied) MP-43 tripod mount Frame Rate Reference Theoretical value: decimal values are dropped, during Unpacked Resolution Pixel Frame Rate...
  • Page 104: Spectral Response

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous Spectral Response - 104 -...
  • Page 105 GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous - 105 -...
  • Page 106: External Appearance And Dimensions

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous External Appearance and Dimensions Notes: Dimensional tolerance: ± 0.3mm Unit: mm - 106 -...
  • Page 107: User's Record

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Miscellaneous User's Record Model name: Revision: …………… Serial No: …………… Firmware version: …………… For camera revision history, please contact your local JAI distributor. - 107 -...
  • Page 108: Revision History

    GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0) Revision History Revision History Revision Date Changes Combined GO-2400M-PGE / GO-2400C-PGE and GO-2401M-PGE / GO- 2401C-PGE User Manuals. Corrected/updated topics. 2023/04/28 Device Version Appicable Model Name DV0145 GO-2400M-PGE DV0146 GO-2400C-PGE, GO-2401M-PGE, GO-2401C-PGE Previous Revisions (2.x)

This manual is also suitable for:

Go-2400c-pgeGo-2401m-pgeGo-2401c-pge

Table of Contents