Summary of Contents for Delta WHITEWATER DF Series
Page 1
October 2019 AEROBIC RESIDENTIAL WASTEWATER TREATMENT SYSTEM INSTALLATION, OPERATION AND MAINTENANCE MANUAL Delta Treatment Systems 9125 Comar Drive Walker, LA 70785 (225) 665-6162 (800) 219-9183 www.deltatreatment.com info@deltatreatment.com Delta Treatment Systems is a wholly owned subsidiary of Infiltrator Water Technologies, LLC...
Page 2
DISTRIBUTOR AND HOMEOWNER NOTES The Delta Treatment Systems Model DF40-M has been tested by NSF International and conforms to NSF/ANSI Standard 40, class 1 effluent requirements. All other DF series models are certified based on provisions in the standard for certification of a series of plants of the same model varying only in rated treatment capacity and materials of construction.
If you did not receive a copy, call 1-800-219-9183 and we will send you one at no charge. KEEP A RECORD OF SERVICE BELOW: DATE SERVICE PROVIDED SERVICE TECHNICIAN Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 4
Systems, LLC, a wholly owned subsidiary of Infiltrator Water wastewater enters directly into the mixing chamber. Mixing is Technologies. accomplished by air passing from the air pump to the air Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Delta Treatment Systems is not responsible for the in-field operation of a system, other Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
• Turn off air pump. suspension. • Refill with clean water. • Pump out two-thirds of the tank volume with the suction pipe opening being placed at the tank bottom. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 7
Begin analysis as soon as possible because of the impracticality of preserving the sample. Refrigerate sample at 4ºC to minimize microbiological decomposition of solids. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
PIPE OFFSET TO MIN 6" BE 1/2" THE PORT DEPTH PIPE DIA. SAMPLE PORTS DATE: SCALE: DWG. NO.: DWN BY: NOT TO RYAN D. 7/26/2019 CRT361 SCALE Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Do not install the air pump(s) in a low-lying area where water may accumulate. The air pump should be installed near the control panel and within 100 ft. of the tank. The air pump Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Place hose in six inch riser. Begin filling tank with water. CONTROL PANEL COMPRESSOR POWER CORD MAIN POWER COMPRESSOR CORD HOUSING AIRLINE TO TANK AIR TUBE STEP 4 STEP 6 STEP 7 Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 11
24” manways and 1 foot from top of tank flange with flat lids. For burial depths beyond 2 feet contact the factory. STEP 9 Grade Elevation Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 12
6. Repeat step 3 and refill the ATU with clean water. *Never leave tank empty. *Always use licensed pumpers/haulers for this task. VACUUM HOSE REFILL WITH CLEAN WATER Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
• Buzzer: Turn all power off to the control panel. Remove screw and debris may appear on the surface. Water is discharged attaching the buzzer to back plate as well as connectors. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
This will provide a positive seal that will not allow any infiltration into or out of the treatment plant. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 15
Air In Effluent Out Influent In CLARIFIER CLEAR WATER Clear ZONE Clarifier Water Zone AERATION CHAMBER DIRTY WATER ZONE Aeration Chamber Dirty Water Zone CROSS SECTION Section Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
AIR PUMP ASSEMBLY ........6 ........SEE AIR PUMP PARTS LIST SAMPLE PORT ..........7........PVC CONTROL PANEL ........8 ........NEMA 3R STEEL OR NEMA 4X FIBERGLASS HIGH WATER FLOAT SWITCH .....9 ........POLYETHYLENE Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Note: For special cargo or container shipments 12 inches must be added to the diameters of all fiberglass units (due to the fiberglass flange and lifting lugs). Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 18
(with cover removed) Outlet To Tank Linear Outlet Rotary To Tank Grade Elev. As Required To 4” Inlet G To 4” Outlet G Air Drop Line Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 19
To 3/4" Air Inlet C To 4" Inlet C To 4" Outlet C Air Drop Line Deflector Section A-A HIGH LEVEL FLOAT NOT REQUIRED WHEN USING CP22 SERIES CONTROL PANELS Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 20
TUBING CONNECTIION ASSEMBLY DRAWING Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 21
THIS PAGE INTENTIONALLY LEFT BLANK. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 22
CP20 CONTROL PANEL Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 23
CP20 WIRING DIAGRAM Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 24
CP 22 CONTROL PANEL Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 25
CP 22 WIRING DIAGRAM Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 26
CONTROL PANEL CONNECTIONS USING ROTARY SERIES COMPRESSORS CONTROL PANEL CONNECTIONS USING ROTARY SERIES COMPRESSORS Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 27
CIRC�1R�KER CONTROL PANEL CONTROL PANEL WIRf: STRAIN RELIEF W/RUBBER BUSHING SCH. SCH. CONDUIT -- 3/4• 3/4" PVC CONDUIT NOT REQUIRED WHEN USING CP22 SERIES CONTROL PANELS Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 28
5. SMALL ACCESS PORT SHOWN ON DRAWING LARGE ACCESS PORTS MAY BE SUPPLIED. 6. MINIMUM AMOUNT OF CONDUIT SHOWN ABOVE IS REQUIRED EVEN WITH TYPE UF CABLE. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 29
Conduit and fittings are as shown in the drawings contained in this manual. 20 amp minimum A/C type disconnect switch or equal. Required on CP20 series panels only Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 30
DRAWINGS AIR PUMP DRAWINGS AND PARTS LIST 5078S, 5100S-C, 5120S, 5150S, 5200S 5030-A, 5040-A, 5060-A and V models 5006, 5015, 5020 and V models Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 31
Note: Service kits (except C50279) include base gasket, filter cover gasket (where appropriate), L-tubes (2), head and diaphragm assembly (2) and intake filter. Service kit C50279 includes head and diaphragm assembly (2) only. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 33
AIR PUMP DRAWINGS HP SERIES STRUCTURE AND PARTS NAMES Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 34
AIR PUMP DRAWINGS HP SERIES STRUCTURE AND PARTS NAMES Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 35
AIR PUMP DRAWINGS Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 36
AIR PUMP DRAWINGS Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 37
AIR PUMP DRAWINGS AP SERIES STRUCTURE AND PARTS NAMES Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Serial No. 4" 9125 COMAR DRIVE WALKER, LA 70785 1-800-219-9183 ALARM MALFUNCTION ELECTRICAL PANEL DF S ERIES 3" Model NSF/ANSI STDS 40 GPD CLASS 1 Serial No. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 39
HIGH LEVEL FLOAT REQUIRED The DF S eri es WHEN USING CP22 SERIES CONTROL PANELS Model DF NSF-ANSI STDS 40 xxxx GPD Class 1 Serial Number xxxx Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Replacement parts or components may be obtained from your local distributor or contact Delta Treatment Systems for information. COMPLAINTS: In order for Delta Treatment Systems to properly address complaints, we require that you put in writing the date and nature of the complaint as detailed as possible. This MUST include the serial number of your system.
Page 41
You’ll also save water, other engineered system, like your heat pump or energy, and pumpout costs, too! Don’t flush dangerous or damaging substances into your system. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 42
Avoid using • When you need to replace an old toilet, replace it powdered detergents. with a low-flush model. • Metal Cleaners for Toothpaste/Lemon: To polish Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 43
• Don’t dig without knowing the location of your potentially be subject to any vehicular traffic place a wastewater system components. barricade like a row of shrubs around it. Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Delta’s installation instructions and local regulation by a licensed installer, is warranted to you: (i) against defective materials and workmanship for two (2) years after installation. Delta will, at its option, (i) repair the defective System or (ii) replace the defective materials.
Need help?
Do you have a question about the WHITEWATER DF Series and is the answer not in the manual?
Questions and answers