Remove
the lower
drain plug
Continuous
drain hose
Drain hose
adaptor
√
√
Drain
hose
adaptor
• During heat pump mode, remove the lower drain
plug from the back of the unit and install the drain
connector (5/8" universal female mender) with 3/4"
hose (locally purchased). For models without drain
connector, just attach the drain hose to the hole. Place
the open end of the hose adaptor directly over the
drain area in your basement floor.
NOTE
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain, making sure that
there are no kinks that will impede water flow. Place
the end of the hose into the drain and make sure the
end of the hose is directed downward to let the
water flow smoothly. (See Figs with
not recommended. (See Figs with
continuous drain hose is not used, ensure that the
corresponding drain plug and knob are installed
firmly to prevent leakage.
Drain
hose
adaptor
Press the power
cord buckle into
the rear cover
• When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times. The digital
display shows "P1." At this time the air conditioning/
dehumidification process will immediately stop.
However, the fan motor will continue to operate (this
is normal). Carefully move the unit to a drain location,
remove the bottom drain plug and let the water drain
away. Reinstall the bottom drain plug and restart the
machine until the "P1" symbol disappears. If the error
repeats, call for service.
NOTE
Be sure to reinstall the bottom drain plug firmly to
prevent leakage before using the unit.