Advertisement

Quick Links

Operation manual
Daikin Altherma 3 R F+W
EBBH11D▲6V▼
EBBH11D▲9W▼
EBBH16D▲6V▼
EBBH16D▲9W▼
EBBX11D▲6V▼
EBBX11D▲9W▼
EBBX16D▲6V▼
EBBX16D▲9W▼
EBVH11S18+23D▲6V▼
EBVH11S18+23D▲9W▼
EBVH16S18+23D▲6V▼
EBVH16S18+23D▲9W▼
EBVH16SU23D▲6V▼
EBVX11S18+23D▲6V▼
EBVX11S18+23D▲9W▼
EBVX16S18+23D▲6V▼
EBVX16S18+23D▲9W▼
Operation manual
English
▲= A, B, C, ..., Z
Daikin Altherma 3 R F+W
▼= , , 1, 2, 3, ..., 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma 3 RW and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin Altherma 3 RW

  • Page 1 Operation manual Daikin Altherma 3 R F+W EBBH11D▲6V▼ EBBH11D▲9W▼ EBBH16D▲6V▼ EBBH16D▲9W▼ EBBX11D▲6V▼ EBBX11D▲9W▼ EBBX16D▲6V▼ EBBX16D▲9W▼ EBVH11S18+23D▲6V▼ EBVH11S18+23D▲9W▼ EBVH16S18+23D▲6V▼ EBVH16S18+23D▲9W▼ EBVH16SU23D▲6V▼ EBVX11S18+23D▲6V▼ EBVX11S18+23D▲9W▼ EBVX16S18+23D▲6V▼ EBVX16S18+23D▲9W▼ Operation manual English ▲= A, B, C, …, Z Daikin Altherma 3 R F+W ▼= , , 1, 2, 3, …, 9...
  • Page 2: Table Of Contents

    To turn ON or OFF............11 for basic and advanced usage Reading out information ............11 Space heating/cooling control ........... 12 ▪ Format: Digital files on https://www.daikin.eu. Use the search 5.6.1 Setting the space operation mode ......12 function to find your model.
  • Page 3: User Safety Instructions

    Waste batteries MUST be treated at a specialised treatment facility for reuse. By ensuring waste batteries are disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 4: Instructions For Safe Operation

    The amount of information you can read and edit in the menu structure depends on your user permission level: ▪ If not, you can purge air immediately. Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 5: Space Heating/Cooling

    During room temperature control, you can use the room temperature Zone Go to … setpoint screen to read out and adjust the desired room temperature. Main zone – Heating [2.5] Main zone > Heating WD curve EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 6: Domestic Hot Water

    "5.6 Space heating/cooling Example" [ 4  14] ▪ "5.8 Schedule screen: ▪ "5.8 Schedule screen: Example" [ 4  14] ▪ User reference guide curve" [ 4  15] ▪ "5.9 Weather-dependent ▪ User reference guide Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 7: Operation

    Dials and buttons You use the dials and buttons: ▪ To navigate through the screens, menus and settings of the LCD screen ▪ To set values EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 8: Menu Structure: Overview User Settings

    Only applicable for models where cooling is possible (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 9: Possible Screens: Overview

    Go through the list of the main menu. Go to the main menu screen. Holiday mode Enable/disable breadcrumbs. Holiday mode active Item Description a Domestic hot water Domestic hot water Measured tank temperature EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 10: Main Menu Screen

    Item Description Set the leaving water temperature for the additional zone (if present). Minimum temperature limit Fixed by the unit Restricted by the installer Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 11: Detailed Screen With Values

    [8.7] About Version information about the system [8.8] Connection status Information about the connection status of the unit, the room thermostat and WLAN. Tank heating operation ON EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 12: Space Heating/Cooling Control

    During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature. 1 Go to [1]: Room. Room Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 13: Domestic Hot Water Control

    To check if powerful operation is active is displayed on the home screen, powerful operation is active. Activate or deactivate Powerful operation as follows: 1 Go to [5.1]: Tank > Powerful operation EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 14: Schedule Screen: Example

    In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 15: Weather-Dependent Curve

    5 Select Saturday. building, the curve can be adjusted by an installer or user. 6 Select Copy. EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 16: 2-Points Curve

    Possible actions on this screen X1, X2 Examples of outdoor ambient temperature Go through the temperatures. Change the temperature. Go to the next temperature. Confirm changes and proceed. Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 17: Using Weather-Dependent Curves

    It will take more time and energy to heat up/cool Additional zone – Cooling [3.6] Additional zone > down the room again. Cooling WD curve EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 18: Maintenance And Service

    ▪ Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 19: Symptom: You Are Feeling Too Cold (Hot) In Your Living Room

    ▪ For EBBH/X: The backup heater automatically takes over the heat load, and the booster heater in the optional tank takes over the domestic hot water production. EBBH/X11+16D + EBVH/X11+16S(U)18+23D Operation manual Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...
  • Page 20: Disposal

    Additional capacity step 2 [9.3.5] (if applicable) Main zone Emitter type [2.7] Control [2.9] Setpoint mode [2.4] Schedule [2.1] WD curve type [2.E] Additional zone (only if [4.4]=1, dual zone) Operation manual EBBH/X11+16D + EBVH/X11+16S(U)18+23D Daikin Altherma 3 R F+W 4P643605-1B – 2022.08...