TTB 3045NX 36V Control Panel Overview Battery Charge Level Display Water Flow On / Off Button In the event of a breakdown contact Water Flow Indicator your Numatic dealer or the Vacuum Off/On Indicator Numatic Technical Vacuum Off/On Button help line +44 (0)1460 269268 Handle Position Lever Start Switch Triggers www.numatic.co.uk...
Machine Set-up Guide ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF BEFORE MAKING ANY ADJUSTMENTS Fitting the Brush / Pad / Turn on water 450mm Brush or 400mm Pad. Featuring the Nulock brush system. The brush is simply pushed and twisted to lock, making fitting and removal a simple process. Slide the brush / pad under the brush deck. Fit the brush / pad onto the Nulock drive chuck, twist to lock the brush / pad in place.
For best results use a non-foaming type of chemical recommended for use in auto scrubber dryers, dilute to the manufacturers specification. For further guidance on hazardous substances refer to health and safety instructions online. WHEN HANDLING AND MIXING CHEMICALS Always ensure that chemical manufacturer’s safety guidelines are followed. Only use chemicals recommended for use in auto scrubber-dryers. www.numatic.co.uk...
Machine Set-up Guide Handle Height Adjustment Using the handle position lever, lower the handle to a comfortable working position. IMPORTANT Do not operate machine unless the Operator Manual has been read and fully understood. The machine is now ready to be moved to the cleaning site.
(Transit mode) simply lift the deck and the spring loaded locking pin will activate to hold the deck up. Setting the Cleaning Controls On / Off Trigger Trigger To check the battery level pull one of the Triggers or press button (A). Adjust water flow using the fluid control tap (B). www.numatic.co.uk...
To start the brush with the configured water and vacuum settings pull either trigger and press the Start switch (A). The running state of the vacuum (D) and water (C) can be adjusted whilst the brushes are running. To cancel vac overrun press any switch (vac/water/handle/start) System Error Indicators In the event of a fault the battery lights (F) will flash and the unit will stop operating.
Brush Pressure / Load Adjustment Using the Deck Pressure Weights. To obtain the best out of your TTB.3045.NX Numatic have supplied a ‘Deck Pressure Weight’ allowing the operator to add or remove pressure on the brush or pad for optimum performance on all floor types. Remove the Top (Waste Water) tank (1). Set in the lower tank are location pillars (2) to locate the Deck Pressure Weights (5).
ALWAYS ENSURE THAT THE FLOOR IS PRE-SWEPT AND RELEVANT SAFETY SIGNS ARE DISPLAYED. Machine In Use To operate, set water flow rate tap, lower brush deck, lower the floor tool, press the vacuum / water switches, pull brush On/Off trigger. The waste water is then retrieved by the suction floor tool. Overlap each scrubbing path by 10cm to ensure an even clean. Do not operate the machine on inclines that exceed (2%), when full. On heavily soiled floors use a ‘double scrub’ technique.
Replacement is a reversal of the removal process. Floor Tool Overview 1. Retaining pins x 4 2. Front blade (slotted) 3. Blade carrier 4. Rear blade 5. Floor tool main body Note: The blades are designed to be reversible, thus extending their useful working life. www.numatic.co.uk...
Protection Wet Floor Sign Note: A risk assessment should be conducted to determine which PPE should be worn. In the event of a breakdown contact your Numatic dealer or the Numatic Technical help line +44 (0)1460 269268 T 01460 68600...
Regularly examine the power cord for damage, such as cracking or ageing. If damage is found, replace the cord before further use. • Only replace the power cord with the correct Numatic approved replacement parts. • Ensure that the work area is clear of obstructions and / or people.
36V | 8400mAh | 300Wh | 10INR19/65-3 It is important that you observe the following information and warnings! Emergency Contact Informa� on Address: CBAK BATTERY HEADQUARTERS NUMATIC INTERNATIONAL LTD Shenzhen BAK ENERGY Co. LTD, Millfi eld Road, 2603A BAK Tech Bldg, Chard,...
• Do not use defective or deformed batteries. • Use only original NUMATIC chargers to charge the battery. • STORAGE: Good batteries should be stored in a protected area away from sources of direct heat and sunlight and should be kept dry.
Page 18
Use and store the battery with-in temperature range (as shown in Temperature Range Table). • Warning: The battery included in this product must only be charged by the Numatic Charger and docking system supplied with the product and in NO circumstances should an alternative non Numatic charger be used as there is risk severe damage and fi re could result.
To this end, batteries must be handed over for disposal to the collection systems established for this under national law. Disposal of batteries together with household waste is prohibited; batteries must be collected separately according to type. Return the battery free of charge to your NUMATIC servicing dealer for disposal or hand it over to an appropriate public • collection point.