Your Studio Pro 28 has been shipped in 3 sections for easy placement. Narrow doorways and halls are possible to navigate with each of the 3, individual
sections. This allows you to place the kiln where it would be otherwise impossible or impractical to do with a kiln of this size.
SAFETY
Read and understand these installation instructions for safe and proper installation. Installation requires the lifting and moving of individual kiln sections.
Personnel capable of lifting and managing the moving process must be used. If you have any questions please contact Evenheat Kiln at 989-856-2281 or at
evenheat-kiln.com.
Kilns are as safe as any other electrical appliance when used under normal and proper operating conditions. To create and maintain this safe environment
observe all installation and safety precautions.
Warning Symbol Descriptions
Warning symbols are used throughout these installation instructions. These symbols alert the installation personnel to certain hazards and important
information. Pictured below are symbols used along with a description of each.
The Exclamation Point alerts you to particular cautions, hazards and information.
The Lightning Bolt alerts you to specific information regarding the risk of electric shock.
Electric shock may result in injury or death.
Emergency Shut Off Provision
The kilns power supply connection (plug/receptacle, breaker or disconnect) acts as the emergency electrical power shut off. Access to these
devises should be unobstructed and safe at all times.
All electrical installations for direct wired models (those without a plug/receptacle connection) must include a power disconnect near the kiln and that
is easily accessible and safe for emergency power shutoff.
Electrical Safety
A licensed electrician should be used for all electrical installation and service. All applicable local, state and federal electrical codes must be
followed.
Use correct voltage, wire size and fuse or breakers. Kiln electrical requirements are located on the kiln nameplate. Make sure all electrical connections
are tight. Avoid using aluminum wire.
Always use the proper electrical receptacle. Never alter the kiln cordset or cordset plug. Alterations can be dangerous. Alterations will void any
warranties along with nullifying any Listing Agency markings.
Evenheat recommends that a voltage check be performed before placing the kiln into service, ideally before actual purchase. Operating
voltage varies, with common operating voltages being 208V and 280V. The kilns operating voltage (printed on the kilns nameplate) must
match the applied voltage (actual electrical service voltage). If it does not, do not install or operate the kiln as potential electrical and fire
hazards exist. Contact Evenheat for guidance in such cases.
The kiln must be properly grounded.
Unplug or disconnect the kiln from the electrical service before accessing the chamber for servicing or vacuuming. Do not attempt to touch
or replace the heating elements while the kiln is plugged in or connected to the electrical service. Electric shock may result in serious injury
or death.
Never, ever use an extension cord to operate a kiln.
Studio Pro 28
Installation and operating Instructions
North American Model
Jan 2019
Page 1 of 16

Advertisement

loading
Need help?

Need help?

Do you have a question about the Studio Pro 28 and is the answer not in the manual?

Questions and answers

Summary of Contents for Evenheat Studio Pro 28

  • Page 1 Jan 2019 Your Studio Pro 28 has been shipped in 3 sections for easy placement. Narrow doorways and halls are possible to navigate with each of the 3, individual sections. This allows you to place the kiln where it would be otherwise impossible or impractical to do with a kiln of this size.
  • Page 2 Do not place or use kiln on combustible surface. Place only on the metal stand provided by Evenheat Kiln, Inc. The surface on which the kiln is placed shall be capable of safely supporting the combined weight of the kiln, kiln load and any operating personnel.
  • Page 3 Replace any worn, damaged or defective parts immediately with Evenheat Kiln replacement parts only. Discontinue use until parts are replaced. When vacuuming the kiln use only HEPA filters on the vacuum. Prolonged expose to brick dust and other refractory materials can cause lung injury.
  • Page 4 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Assembly & Installation Tools needed for installation: Phillips Screwdriver 7/16” Wrench 1/4” Nutdriver (included) Remove Shipping Container and Top Styrofoam Cut the plastic shipping bands and remove the shipping container lid.
  • Page 5 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Repeat with the remaining 3 stand corners to complete the stand perimeter. Install the 4 plastic stand feet on the stand. The kiln stand is now completely assembled and may be moved to the desired kiln location.
  • Page 6 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Move and Place the Kiln Floor on the Kiln Stand Move the floor to the kiln stand and place it into the stand. The kiln floor chamber weighs approximately 60 pounds. Two people are needed for moving.
  • Page 7 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Proper lifting and chamber rotation. Please note from images that the back lid hinges are located at the top as the chamber is rotated. Also note that the lid side of the chamber, as it rotates and once rotated, becomes heavier than the non-lid side. The men in this image slowly rotated the chamber and felt, and reacted to, this weight shift.
  • Page 8 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Route the conduit to back of stand as shown. Secure the power interrupt switch conduit in the conduit clamp on the floor base as shown. Installing the Lift Assist Springs Installation of the Lift Assist Springs is a 2 person job.
  • Page 9 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Properly placed lift assist springs, back right. Properly placed lift assist springs, back left. Chamber Safety Bar and Lid Support Bar Installation Locate the included Chamber Safety and Lid Support Bars. You will note, as You will install the Chamber Safety Bar first.
  • Page 10 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Place the chamber safety bar through the wireform catch and onto the Please note that the notch in the chamber safety bar is to be mounting plate stud as shown.
  • Page 11 Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 You will note a mounting plate with stud on the right side of the kiln lid. Place the lid support bar through the wireform catch as shown. You will also notice a wireformed catch directly below it. These items are involved with the installation of the Lid Support Bar.
  • Page 12: Installation Complete

    Studio Pro 28 Installation and operating Instructions North American Model Jan 2019 Installation Complete Kiln placement and installation is now complete. Please refer to the operating instructions for proper placement of electrical receptacles, power source disconnects and other electrical power requirements.
  • Page 13 Studio Pro 28 Features Dual Access Design The Studio Pro 28 features a Dual Access Design. The Dual Access Design simply means you have the choice of entering the chamber through the Top or through the Front. Front entry offers its own unique advantages. Front entry grants wide open access to the kiln floor. This wide open access is excellent for ware placement, particularly for ware that cannot be moved once positioned.
  • Page 14 Place your Studio Pro 28 in a location that offers a level, non combustible surface. The Studio Pro 28 should be placed no closer than 12” from any wall or 36” from any ceiling surface in all opened and closed positions. All flammable and combustible materials should be removed from the kiln area.
  • Page 15 Kiln Installation Your Studio Pro 28 has been shipped in 3 sections for easy placement. Narrow doorways and halls are possible to navigate with each of the 3, individual sections. This allows you to place the kiln where it would be otherwise impossible or impractical to do with a kiln of this size.
  • Page 16 Initial Kiln Maintenance (Chamber Tightening) The Studio Pro 28 uses worm-gear clamps to secure the stainless steel chamber jacket to the brick chamber. During firing, particularly on a new kiln, the stainless steel jacket expands causing the worm-gear clamps to loosen slightly. These worm-gear clamps (located on the left side of the chamber) must be check for tightness and tightened if necessary.