To replace the control cages
1. Remove the feed spouts.
 
 
2. Remove the cage clamps and the control cages.
 
 
3. Install the control cage in opposite sequence.
To replace the blastwheels
1. Remove the feed spouts and the control cages.
To replace the control cages on page 22 .
Refer to
22
2. Remove the nuts of the blastwheel covers.
 
 
3. Install M10 bolts on the welded nuts. Turn the M10
bolts to release the blastwheel covers from the blast
housings.
 
 