TECHNICAL SPECIFICATIONS 11.1 CONTAINERS ARRANGEMENT ICE CREAM CONTAINERS 11.2 INSTALLATION 11.3 LOAD LIMITS 11.4 LIGHTING (LED) 11.5 POSITIONING 11.6 OPEN/CLOSE SELF ROLLING CURTAIN CONTROL PANEL 12.1 USER INTERFACE CLEANING PROLONGED APPLIANCE SWITCH-OFF BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Page 3
Attention / Danger Important information Operations that must be performed by two Information persons. Visual observation Notes / Important notes Condensing unit on board Remote condensing unit BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
1. MANUFACTURER ISA S.r.l. Via del Lavoro, 5 06083 - Bastia Umbra - Perugia - Italy Tel. +39 075 80171 Fax +39 075 8000900 www.isaitaly.com 2. WARRANTY TERMS AND CONDITIONS The seller's warranty on the equipment is valid for 12 (TWELVE) months from the date of delivery.
Absorption during Defrosting Absorption of Heating Elements Lamp Power Fuse Value Climate Class Number of Motors Type of Coolant Amount of Coolant Safety Class 22 - 23 Customer order RAEE Mark BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
Electric system • Electronic controller • Insulated monolithic structure in ecological polyurethane • Operator side closure with self rolling curtain • Four (4) swivel casters (2 with brakes) • Lighting LED BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Keep this manual in a safe place. It should be available for consultation near the equipment at all times. If lost or destroyed, you can request a copy of the manual from ISA S.r.l. by specifying the exact model, serial number and year of manufacture. The manual refl ects the manufacturing technology at the time of supply.
Page 8
INTRODUCTION ISA S.r.l. employs materials of the best quality and as they enter the company, we constantly monitor their storage and the use as part of the manufacturing process to prevent damage, deterioration and failure.
If this is not the case, the user must envision the relevant limiting devices. It is strictly forbidden to conduct any electrical modifi cation, in order to prevent additional unforeseen hazards and risks. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
Do not place any goods and in general, do not load the tank sliding element closing devices with any load, while open or closed. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL...
Follow the guidelines on how to use the cabinet. If a product package breaks, remove it from the cabinet and clean, if necessary. BERMUDA USE AND MAINTENANCE MANUAL...
The refrigerant system is High Pressure. Do not tamper with the system, but call a specialised and qualifi ed technician before disassembly. Maintenance must be performed exclusively by qualifi ed staff. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Further information on the disposal of liquid coolant, oils and other substances is available on the safety data sheet corresponding to the substance itself. In order to dispose of foamed assemblies, remember that the polyurethane foams used are CFC, HFC and HCFC free. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
III (3) over-voltage conditions and therefore protects the circuits against earth faults, overloads and short circuits. Do not route the electricity cable in passageways. Attention Earthing is necessary and mandatory by law. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
REPLACEMENT POWER SUPPLY CABLE, PLUGS AND / OR ELECTRICAL SOCKETS Attention After all maintenance it is mandatory to perform all electric safety tests in agreement with the IEC EN 50106 Standard. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
Check the reasons why the pressure switch is operating at maximum pressure at maximum pressure levels, such as: air condensing unit TECHNICAL blocked, condensing unit fan stopped, ambient temperature ASSISTANCE too high, pressure switch broken. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
If the alarm does not stop, replace the clock. Machine parameter error. • The instrument is damaged. It must be replaced. Operating parameters error. • The instrument is damaged. It must be replaced. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
The limits given refer to a static load and evenly distributed. Are therefore excluded dynamic overloads due to loading operations violent, ranging absolutely avoided for safety reasons. 11.4 LIGHTING (LED) BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
The equipment is set up with four (4) swivel casters (2 with brakes) for easy handling and positioning. It is absolutely necessary after placement stabilize the equipment on the fl oor. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Scroll through the self rolling curtain without force and ensure complete / correct closure; not the complete / correct closure will cause the negatively affects performance of the equipment and on the excessive ice buildup on the inner walls. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS...
Any changes to the control board settings can be carried out exclusively by qualifi ed technical personnel. At start-up, the instrument conducts a LAMP TEST for a few seconds. The display and leds fl ash to verify their integrity and to ensure they are working correctly. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL...
By not operating on the keyboard for more than 15 seconds (time-out) or pressing the STAND-BY (ESC) key once, the last value displayed is confi rmed and you go back to the previous display. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS...
Page 26
E1. The alarm signal deriving from a faulty evaporator probe (probe 2) appears directly on the instrument display with the indication E2. FANS ON for operating fans. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Fit the accessories that were removed (step 3). 10. Turn on the equipment and allow to cool on the bench for at least 2 hours or until it reaches the desired temperature before reintroducing foods. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS...
Page 28
Sanitize the tray with specifi c products. BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
• The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the elements and direct sunlight, at a temperature between 0 and +40 °C. BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS...
Page 30
Attachment 1 - DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY We: ISA S.r.l. Via del Lavoro, 5 - 06083 - Bastia Umbra (PG) declare under our own responsibility, that the product: BERMUDA Product: Serial number: ..To which this declaration refers, is in compliance with e following: MACHINERY SAFETY General electric safety Standard EN 60335-1: 2012-01+Modifi...
Page 31
Attachment 2 - WIRING DIAGRAM - 412100725000 BERMUDA USE AND MAINTENANCE MANUAL ICE CREAM CABINETS 428000668037...
Page 32
Attachment 2 - WIRING DIAGRAM - 412100726000 BERMUDA ICE CREAM CABINETS USE AND MAINTENANCE MANUAL 428000668037...
Need help?
Do you have a question about the BERMUDA and is the answer not in the manual?
Questions and answers