Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
April 2020
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
1 1 8 8 - - G G J J 8 8 2 2 D D 1 1 - - 1 1 E E - - E E N N
N N o o t t e e : : "Graphics in this document are for representation
only. Actual model may differ in appearance."
N N o o t t e e : : For use with BAYEA series heaters ONLY
Summary of Contents for American Standard TAM9A0A24V21DA
Page 1
Installer’s Guide Variable Speed Air Handlers Convertible 2 — 5 Ton TAM9A0A24V21DA TAM9A0B30V31DA TAM9A0C36V31DA TAM9A0C42V41DA TAM9A0C48V41DA TAM9A0C60V51DA N N o o t t e e : : “Graphics in this document are for representation only. Actual model may differ in appearance.”...
Page 2
SAFETY SECTION AIR HANDLERS I I m m p p o o r r t t a a n n t t — This document contains a wiring W W A A R R N N I I N N G G diagram, a parts list, and service information.
Installer Guide Notes A A L L L L P P h h a a s s e e s s o o f f t t h h i i s s i i n n s s t t a a l l l l a a t t i i o o n n m m u u s s t t c c o o m m p p l l y y w w i i t t h h N N A A T T I I O O N N A A L L , , S S T T A A T T E E a a n n d d L L O O C C A A L L C C O O D D E E S S ! ! I I m m p p o o r r t t a a n n t t : : This Document is customer property and is to remain with t his unit.
Unit Design Table 1. Cabinet Penetration Screws are allowed up to 3- 3/4” from the top of the cabinet (heater compartment). (Typical both sides) Table 2. Panel Removal 18-GJ82D1-1E-EN...
Page 6
U U n n i i t t D D e e s s i i g g n n 18-GJ82D1-1E-EN...
Page 10
O O p p t t i i o o n n a a l l C C a a b b i i n n e e t t D D i i s s a a s s s s e e m m b b l l y y Coil Support Channel 18-GJ82D1-1E-EN...
Page 11
O O p p t t i i o o n n a a l l C C a a b b i i n n e e t t D D i i s s a a s s s s e e m m b b l l y y 18-GJ82D1-1E-EN...
Page 12
O O p p t t i i o o n n a a l l C C a a b b i i n n e e t t D D i i s s a a s s s s e e m m b b l l y y 18-GJ82D1-1E-EN...
Four-Way Conversion Refrigerant Connections Low Voltage Connections Inside Unit Low Voltage Connections Control Inside Unit Pocket Inside Unit Control Pocket Inside Unit Upflow Condensate Drains Refrigerant Connections Downflow Condensate Drains Upflow Configuration 18-GJ82D1-1E-EN...
Page 16
F F o o u u r r - - W W a a y y C C o o n n v v e e r r s s i i o o n n Horizontal Left Configuration Airflow Low Voltage Horizontal Left Refrigerant...
Ducted and Non-Ducted Return Applications Table 4. Non-Ducted Applications C C A A U U T T I I O O N N Supply Duct H H A A Z Z A A R R D D O O U U S S V V A A P P O O R R S S ! ! F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w t t h h i i s s C C a a u u t t i i o o n n c c o o u u l l d d r r e e s s u u l l t t i i n n p p r r o o p p e e r r t t y y d d a a m m a a g g e e o o r r p p e e r r s s o o n n a a l l i i n n j j u u r r y y .
Additional Unit Preparation Considerations For proper installation the following items must be • Consider the overall space needed when external considered prior to moving the unit to its installation accessories are used, additional height and width site: requirements may exist. •...
Setting the Unit — Vertical Installation Table 6. Considerations Table 7. Upflow Installation Airflow Airflow 18-GJ82D1-1E-EN...
Page 20
S S e e t t t t i i n n g g t t h h e e U U n n i i t t — — V V e e r r t t i i c c a a l l I I n n s s t t a a l l l l a a t t i i o o n n Table 8.
Setting the Unit — Horizontal Installations Table 10. Considerations Field Supplied Isolators Auxiliary Drain Bottom Support Near Both Ends 18-GJ82D1-1E-EN...
Refrigerant Line Table 12. Refrigerant Line Connection Sizes Refrigerant System Layout Vapor Line Liquid Line Strainer Evaporator Temperature Sensor (ET) - Located on 3/8” aluminum distributor tube (orange wires) Gas Temperature Sensor (GT) - Located on copper section of manifold EEV Stepper Motor (black wires) 18-GJ82D1-1E-EN...
Electrical — Low Voltage Table 14. Low Voltage Maximum Wire Length Table 15. Low Voltage Hook-up Instructions 5” 18-GJ82D1-1E-EN...
Page 31
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e 18-GJ82D1-1E-EN...
Page 32
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e Communicating Controls Wiring Diagram COMMUNICATING COMFORT...
Page 33
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e 1 OR 2 STAGE HEAT PUMP WITH TAM9/TAMG VARIABLE SPEED AIR HANDLER COMFORT CONTROL NOTES:...
Page 34
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e SELECT Button Airflow Control (AFC) LIST Button...
Page 35
E E l l e e c c t t r r i i c c a a l l — — L L o o w w V V o o l l t t a a g g e e Table 16.
Electrical — High Voltage Table 17. High Voltage Power Supply W W A A R R N N I I N N G G L L I I V V E E E E L L E E C C T T R R I I C C A A L L C C O O M M P P O O N N E E N N T T S S ! ! F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w t t h h i i s s W W a a r r n n i i n n g g c c o o u u l l d d r r e e s s u u l l t t i i n n p p r r o o p p e e r r t t y y d d a a m m a a g g e e , , s s e e v v e e r r e e p p e e r r s s o o n n a a l l i i n n j j u u r r y y , , o o r r d d e e a a t t h h .
Page 38
E E l l e e c c t t r r i i c c a a l l — — H H i i g g h h V V o o l l t t a a g g e e BLACK GREEN - GROUND 18-GJ82D1-1E-EN...
Page 39
E E l l e e c c t t r r i i c c a a l l — — H H i i g g h h V V o o l l t t a a g g e e 18-GJ82D1-1E-EN...
TAM9 OUTLINE DRAWING NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE 18-GJ82D1-1E-EN...
Display Assembly / Human Interface Display Assembly Viewing Window Push up & down to scroll through setup menu Push center button Push left & right to scroll to make selection through menu options D D i i s s p p l l a a y y A A s s s s e e m m b b l l y y G G e e n n e e r r a a l l N N o o t t e e s s To Exit the technician menu section, press the Up/Down menu keys simultaneously for 10 •...
TAM9 — Technician Menu and Configuration tree Table 19. CDA Home Screen Home Screen Auto scroll SYSTEM STATUS UNIT DATA ↕ UNIT CONTROLS ↕ XXXXXXXXXXXXXX ↔ ↔ ↔ ALERT 1 <Cntrl> UNIT MODEL # ↕ AFC SW BUILD ↕ AFC SW VERSION <Alert short text>...
Page 43
T T A A M M 9 9 — — T T e e c c h h n n i i c c i i a a n n M M e e n n u u a a n n d d C C o o n n f f i i g g u u r r a a t t i i o o n n t t r r e e e e Table 20.
Page 44
T T A A M M 9 9 — — T T e e c c h h n n i i c c i i a a n n M M e e n n u u a a n n d d C C o o n n f f i i g g u u r r a a t t i i o o n n t t r r e e e e Table 21.
Page 45
T T A A M M 9 9 — — T T e e c c h h n n i i c c i i a a n n M M e e n n u u a a n n d d C C o o n n f f i i g g u u r r a a t t i i o o n n t t r r e e e e Table 22.
Page 46
T T A A M M 9 9 — — T T e e c c h h n n i i c c i i a a n n M M e e n n u u a a n n d d C C o o n n f f i i g g u u r r a a t t i i o o n n t t r r e e e e Table 23.
TAM9 Sequence of Operation Abbreviations N N o o t t e e : : Delay profiles from the thermostat may change blower motor timing and actual airflow demand. • AFC = Airflow Control • EVC = Expansion Valve Control H H e e a a t t p p u u m m p p ( ( c c o o m m p p r r e e s s s s o o r r o o n n l l y y ) ) •...
Page 50
T T A A M M 9 9 S S e e q q u u e e n n c c e e o o f f O O p p e e r r a a t t i i o o n n 3.
Checkout Procedures This product may be covered by one or more of the following patents and their foreign equivalents: 5621888, 5901156, 6208263, 6353376, and 6448901. Other patents are pending. Made under license. 18-GJ82D1-1E-EN...
Page 56
About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.