CAME S0002 - Keypad Selector-Switch Card Manual

CAME S0002 - Keypad Selector-Switch Card Manual

Also See for S0002:

Advertisement

CAME S0002 - Keypad Selector-Switch Card Manual

CARD COMPONENTS

CARD COMPONENTS

  1. Memorise button
  2. LED signal light
  3. DIP-switch for selecting functions
  4. Connection terminals

INSTALLATION

INSTALLATION

The card can be placed either inside the CAME panel or outside of it, in a suitable box. .

ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

  • Make all connections as shown in the diagram :
    • Card ;
    • Power supply 12/24 V ;
    • S5000 keypad terminals ;
    • S6000/S7000 keypad terminals ;
    • N.O. contacts output: Max power rating 5 A-24 V ;
  • for the "OPEN ONLY" function connect terminals C and N.O. of the card to terminals 2-3 of the control panel; whereas for the"OPEN-CLOSE-INVERT" function, connect terminals C and N.O. of the card to terminals 2-7 of the control panel.

N.B. In case the card is powered by DC current respect the + / - polarities.

You can connect up to 5 selector-switches in parallel mode .
PARALLEL MODE CONNECTIONS

MEMORISING CODES

MEMORISING CODES

After making the electrical connections:

  1. key-in the code you wish on the keypad; make sure your intervals do not exceed 10 seconds between one key stroke and the next (otherwise you will have to repeat the code memorising procedure);
  2. press Key E on the keypad;
  3. memorise the code relative to the OUT1 output, by pressing the memorise button. ;
  4. repeat the procedure for OUT2 using a different code. Memorise using the CH2 button. ;

OPERATION

  • Key-in the memorised code; up to 5 code memorisation errors are allowed, then the card deactivates for about 1 minute);
  • press Key E on the keypad .
    OPERATION

N.B.: When working in the monostable mode, keep button E pressed for the desired amount of time (maintained action).

SELECTING FUNCTIONS

Set the dip-switches to obtain the following function on OUT1:

  • MONOSTABLE ;
  • BI-STABLE ;
  • ONE-SECOND IMPULSE ;

Output OUT2 always has a one-second impulse.

TECHNICAL DATA

CARD
POWER SUPPLY POWER DRAW
24 V AC 70 mA max (relay ON)
12 V AC 2.0 mA max (relay ON)
24 V DC 60 mA max (relay ON)
12 V DC 60 mA max (relay ON)
Insulation class III

DECLARATION

- Came Cancelli Automatici S.p. A. declares that this device is compliant with the essential requirements and other pertinent measures established by directive 2006/95/CE 2004/108/CE.

Reference code to request an original copy: DDC E D006.

Dismantling and disposal - Before dismantling and disposing always do the following: check the applicable laws specific to your jurisdiction.

The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and may be disposed of without much trouble, simply by separating them for recycling.

Other components (i.e. control boards, transmitter batteries, etc.) may contain hazardous substances. These must therefore be handed over the specially authorised disposal fi rms.

DO NOT DISPOSE OF IN NATURE!

The data and information in this manual may be changed at any time and without prior notice.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download CAME S0002 - Keypad Selector-Switch Card Manual

Advertisement

Need help?

Need help?

Do you have a question about the S0002 and is the answer not in the manual?

Questions and answers

Table of Contents