ASSEMBLY AND OPERATING INSTRUCTIONS
Explosion Barrier
Ventex ESI-E/D/C
DN100 – 500 Type 6
EXPLOSION PROTECTION
Doc. 8.8701.00.2
Rev. June, 2017
Fire Protection
Explosion Protection
Overpressure Protection
Pressure Activation

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ventex ESI-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Fike Ventex ESI-E

  • Page 1 ASSEMBLY AND OPERATING INSTRUCTIONS Explosion Barrier Ventex ESI-E/D/C DN100 – 500 Type 6 EXPLOSION PROTECTION Doc. 8.8701.00.2 Rev. June, 2017  Fire Protection  Explosion Protection  Overpressure Protection  Pressure Activation...
  • Page 2: Copyright Information

    Fike products. Do not use any Fike products for any application for which it is not intended. Fike shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Fike product for which the product is not intended by Fike.
  • Page 3: Revision History

    REVISION HISTORY : ............................ June, 2017 RIGINAL ELEASE EVISION ESCRIPTION OF HANGE EVISION Doc. P/N 8.8701.00.2 PAGE / 1 Rev. June, 2017...
  • Page 4 TABLE OF CONTENTS Section Page No. INTRODUCTION ..............................3 APPLICATION AND FUNCTION..........................3 DUST LOADING..............................4 PREPARATION FOR INSTALLATION AND OPERATION ..................... 4 INSTALLATION ..............................4 MAINTENANCE AND TEST ............................. 5 TECHNICAL DATA ..............................6 PAGE / 2 Doc. P/N 8.8701.00.2 Rev.
  • Page 5 These assembly and operating instructions apply to the Explosion Barrier Valves VENTEX-ESI-E, -D or –C Type 6 with nominal size DN100-500 mm, without auxiliary energy – refer to nameplate. Included in these instructions is a drawing of the VENTEX valve. The position numbers on the drawing match the numbers in brackets in the instructions.
  • Page 6 The valve is designed for use in pipes in which there is only a minimum dust content in the air. However, experience has shown that under certain conditions dust in the air carried can be tolerated. In any case, before any such installation is carried out, the written consent of the manufacturing company must be obtained.
  • Page 7 3. Install the valve in horizontal/vertical position, refer to nameplate and check process/explosion direction. For horizontal mounting, check position by means of a spirit level. 4. The counter flange and pipe on the explosion side must be designed for a minimum overpressure of 9 bar. 5.
  • Page 8 11. Install the control covers (4). Refer to Fike document X.2.24.01-x Ventex Valve for technical specifications. PAGE / 6 Doc. P/N 8.8701.00.2 Rev. June, 2017...
  • Page 9 Notes:...
  • Page 10 Fike Europe Toekomstlaan 52 2200 Herentals, België Tel: +32 14 210031 www.Fike.com For a list of contact information for Fike offices around the world, visit the Global Locations section of Fike.com...