This manual has been drawn-up for: the Installer and the User.
Specific warning.
Immergas reserves the right to make improvements and changes to details and accessories, excepting the essential features of the model described and illustrated herein.
The mini CRD, including the relative cables and connections to the boiler, must be installed by specialised staff. Upon the free initial check of the boiler, when the mini CRD is inserted into the system, the Immergas authorised after-sales centre checks the connection to the generator terminal board and adjusts operation. The free check of the mini CRD alone is not provided by the Immergas authorised after-sales centre, if requested after the start phase of the boiler warranty.
Attention: laying the mini CRD cables is excluded from the free boiler checks; it is the responsibility of the installer company.
NOTE: for correct installation prepare a dedicated line for the connection of the mini CRD according to the Standards in force regarding electrical systems.
If this is not possible, interference due to other electric cables could cause the mini CRD to malfunction.
![]() | Access to Programming/Display and operating parameter setting. |
![]() | Operating mode change / Programming window change / Boiler reset. |
![]() | Increase of the value selected. |
![]() | Decrease of the value selected. |
Press button several times to switch from one operating mode to the other:
OFF Summer (
) Winter + MAN (
)
Winter + AUTO (
)
OFF.
In OFF mode, Central heating and DHW are disabled, whereas the Antifreeze function is active.
Press to display the DHW set point temperature to display icon
, Sn: XX °C and icon. To change the set value (flashing), press
. To confirm the setting, press button
or wait 5".
Press button twice to display the Maximum Central Heating set point temperature allowed,
Mr: XX °C and icon
. To modify the value set (flashing), use buttons
. To confirm the setting press button
or wait 5".
Press for at least 3" to access the Programming (indicated by icon
). Press
several times to display icons
,
, and XX.X CA, with XX.X flashing to indicate the Room and Comfort Set point. Use buttons
to set the required temperature, which will be used during the Comfort periods programmed for Central Heating. Then press
to access icons
and
and XX.X EA, with XX.X flashing indicate the Reduced Room Set point. Use buttons to set the required temperature, which will be used during the Reduced temperature periods programmed for Central Heating. To return to normal operating mode, press
or wait 60".
Press for at least 3" to access the Programming and display
and the current time, while the day of the week flashes under
. To modify the set value (flashing), use buttons
(1=Monday, 7=Sunday). Press
to set the time. To change the set value (flashing), press
. Press
to set the minutes. To change the set value (flashing), press
. To return to normal operating mode, press
or wait 60".
The time program is a set of 8 times in which the system switches from adjusting the comfort room temperature (ON) to adjusting the reduced room temperature (OFF) and vice-versa.
Note: To exclude a time band, the ON times must correspond to the OFF times.
Time program set from Monday to Friday.
Saturday and Sunday Comfort from 7.00 to 23.00, Reduced from 23.00 to 7.00.
For Central Heating during comfort periods, the value set as Room Comfort Set point (XX.X CA) is used as Room set point, whereas, during the other periods, the value set as Room Reduced temperature set point (XX.X EA) or Reduced is used.
In the event the pre-set program is not efficient, you can change it as described below:
Press for at least 3" to access the Programming and display icons
and
and the current time. Press
several times to display the fixed icons
and
and the flashing icon
and the day of the week (flashing).
Use buttons to select the day or group of days in which the modification regarding the heating time programming must be applied:
1 Monday
2 Tuesday
3 Wednesday
4 Thursday
5 Friday
6 Saturday
7 Sunday
1 5 From Monday to Friday
6 7 Saturday and Sunday
1 6 From Monday to Saturday
1 7 From Monday to Sunday
Press to confirm the day or group of days. The first ON time appears flashing (indicated with icon
and point number 1). Use buttons
to select the ON1 time and pass to the subsequent point 2 by pressing
. The first OFF time appears flashing (indicated by the absence of icon
and point number 2). Use buttons
to select the OFF1 time and pass to the subsequent point 3 by pressing
. Continue this way until the last point OFF4 is reached (point8). To return to normal operating mode any time, press
or wait 60".
Press buttons simultaneously for 10" to display CLr (which will disappear). This way, all the default settings and programming will be restored and the user settings will be deleted permanently.
Function / Window | Factory setting |
Operating prog. | WINTER |
Manual Room set point | 20.0°C |
DHW set | 50°C |
Regulation Constant | 1.5 |
Current time | 00:00 ![]() |
Room Comfort set | 20.0°C |
Room Economy set | 16.0°C |
Maximum central heating set | * |
Building inertia/dimension | 10 |
Regulation Algorithm Type | 3 |
Room Antifreeze Temp. | 5.0°C |
Central Heating time program | Mon..Fri: Comfort 06:00-8:00 / 11:00-13:00 / 17.00-23.00 Sat..Sun: Comfort 07:00-23.00 |
In the presence of a fault, the display will show Er: XX in normal operation mode, where XX indicates the type of fault in the boiler. If Er: XX LC is displayed, the fault can be solved by pressing .
No communication with the boiler.
To access the special functions described below, press and then
for 3''. Then select the required function by pressing
until the corresponding message is displayed. Once you have made the modifications, wait 60" for the mini CRD to return to normal operation.
Regulation algorithm and relative parameters selection
The meaning of the values is the following:
0 AL | room and modulating probes deactivated (the system runs with Central Heating Set Point fixed and settable by the user: (Maximum Central Heating Set point), regardless of the room temperature level). |
1 AL | room probe deactivated and modulation probe activated (the system runs with variable Central Heating Set Point calculated according to the Regulation Constant, regardless of the room temperature level). |
2 AL | room probe activated and modulating probe deactivated (the system runs with fixed Central Heating set point settable when the room temperature is below that set and remains off when it is exceeded) |
3 AL | room probe and modulation probe activated (the system runs with variable Central Heating Set Point calculated according to the Regulation Constant and at the room temperature compared to that set). |
To return to normal operating mode, press or wait 60".
In accordance with Regulation 811/2013 the temperature control device class is:
Class | Contribution to the environmental heating seasonal energy efficiency | Description |
V | +3% | Mini CRD |
VI | +4% | Mini CRD coupled to outer sensor |