Advertisement
1 - Exterior Faceplate
1 - Interior Faceplate
1 - User Guide
2 - Keys
1 - Strike Plate
1 - Mounting Plate
1 - Latch
1 - 1 3/8" Screws
2 - 5/16" Screws
2 - 1" Screws
5 - 3/4" Screws
1 - Electronic Remote
Please carefully check the above list to confirm all items have been received. If any items are missing, please contact Consumer Assistance. (See page for contact information)
Read this manual carefully before installing and operating!
NOTE: Skip this step if your door comes with pre-drilled holes.
NOTE: Do not extend Cylindrical Cover past 2-3/4" (70mm)
TO CONVERT FROM 2-3/8" (60mm) BACKSET TO 2-3/4" (70mm) BACKSET
View from outside of door
Check that the Rubber Gasket is secured on the Exterior Assembly. Insert the Exterior Assembly onto the door with the tailpiece going through the Deadbolt Latch Set in the VERTICAL POSITION. Route the Control Wire through the door under the Deadbolt Latch Set.
NOTE: Make sure the Knob is in the correct position. Be careful not to pinch the control wire when assembling
Lock and unlock using the knob make sure the latch is opening and closing easily. If not, go back to step 2 and ensure you followed the steps
This Electronic lock requires (4) High Quality AA Alkaline batteries. When all 4 batteries are installed in the correct position, you should hear 2 beeps and the keypad will illuminate.
NOTE: Do not touch the Keypad until the light turns off. Do not use rechargeable batteries or non-alkaline batteries.
Press 1-2-3-4-
Before Opening Door Let Motor Complete Cycle
Complete all the programming steps in the programming mode within 5 seconds
Do not press keypad until keypad stops illuminating
Lock / Clear
Unlock / Programming
Administrator Code
SET OR CANCEL AUTO LOCK
You can set the lock to automatically close after each time the lock is opened. Time value range = 20 - 900 seconds, enter the following:
Set Auto Lock:
Hear 1 beep and Light Indicator illuminates green.
To cancel Auto Lock set the time to 00, enter the following:
Cancel Time Value Auto Lock:
Hear 1 beep and Light Indicator illuminates green.
TEMPORARILY DISABLE:
While in Auto-Lock mode, unlock door using , within 10 seconds you must turn the AC locking knob by hand to the locked position, wait more than 2 seconds then turn the locking knob back to the unlock position. The Auto-Lock mode is now disabled.
RESTORE:
To restore the Auto-Lock function, turn the locking knob by hand to the locked position, wait more than 2 seconds or press the Lock button on the keypad.
With Vacation Mode enabled, the system enters into low-power consumption mode. During this mode, all buttons and functions will be disabled until they are re-enabled.
ENABLE:
Once the door is locked then vacation mode will be engaged and all buttons and functions will be disabled
DISABLE:
To disable the Vacation Mode, you must press and hold for more than 3 seconds, then input
followed by
to unlock the door. Vacation Mode is now disabled.
NOTE: If you only press the
for more than 3 seconds but do not input
, the system will remain in Vacation Mode.
Warning sounds and LED flashes red after 4 incorrect code attempts: Keypad shuts down for 60 seconds.
You can "mute" or turn the "sound on" on your lock by entering the following. (Factory setting is sound on).
Sound Off (1) - Light Indicator illuminates green.
Sound On (2) - Hear 1 beep and Light Indicator illuminates green.
To reset the lock to the original factory settings including the Programming Code and all User Codes follow these steps:
Beeps and LED flashes red 7 times. Replace with good quality alkaline batteries.
Note: Removing batteries does not erase active Administrator or User Codes.
Hear 1 beep and Light Indicator illuminates green.
Note: This is the only step you need to use the remote for programming.
Hear 1 beep and Light Indicator illuminates green.
Note: You must have more than 1 remote synced to this lock to DELETE ONE OR ALL REMOTES
Hear 1 beep and Light Indicator illuminates green.
Unlock / Valid programming: | 1 long beep and LED illuminates green |
Lock: | 2 short beeps and LED illuminates red |
Invalid Programming: | 2 short beeps and LED flashes red twice |
Low Voltage: | Short beeps and LED flashes red seven times |
Super Low Voltage: | 4 short beeps and LED flashes red four times |
4 Incorrect code entry attempts: | 2 short beeps and LED illuminates red each attempt |
Power on: | 1 long beep and 1 short beep and LED illuminates green |
Chip Reset: | 1 long beep and 1 short beep and LED illuminates green (may occur several times or once in a while) |
Lock Error: | 3 long beeps LED flashes red three times |
Repeat operation after Lock Error: | 2 short beeps three times LED flashes red six times |
Issue | Solution |
Interior Knob will not turn | Knob or vertical tailpiece is installed in incorrect position.
|
Lock will not function electronically |
|
Lock gives error signal when opening or locking and Deadbolt Latch will not extend or retract completely when door is closed |
|
Deadbolt Latch is sticking | Installation screws of the lock may be too tight and have to be loosened.
|
Keypad not working |
|
Keypad beeps and LED flashes |
|
EMAIL: locks@lewishymaninc.com
WEBSITE: www.truboltlocks.info
ADDRESS: Consumer Assistance Dept.
Lewis Hyman, Inc.
860 East Sandhill Avenue
Carson, CA 90746 USA
TELEPHONE: US/Canada 800-860-1677 Ext. 1801 (Toll Free)
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Tru-Bolt Classic - Digital Deadbolt With Touchscreen Manual
Advertisement
Need help?
Do you have a question about the Classic and is the answer not in the manual?
Questions and answers