Rockwell Automation Allen-Bradley CompactLogix 5370 L3 Installation Instructions Manual

Rockwell Automation Allen-Bradley CompactLogix 5370 L3 Installation Instructions Manual

Advertisement

Quick Links

Installation Instructions
Original Instructions
CompactLogix 5370 L3 Controllers
Catalog Numbers 1769-L30ER, 1769-L30ER-NSE, 1769-L30ERK, 1769-L30ERM, 1769-L30ERMK, 1769-L33ER, 1769-L33ERK, 1769-L33ERM, 1769-L33ERMK,
1769-L36ERM, 1769-L37ERM, 1769-L37ERMK, 1769-L38ERM, 1769-L38ERMK
Topic

Summary of Changes

This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.
Topic
Updated Environment and Enclosure Information
Page
1
5
5
6
6
6
7
7
Page
3
3
4
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Allen-Bradley CompactLogix 5370 L3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rockwell Automation Allen-Bradley CompactLogix 5370 L3

  • Page 1 Installation Instructions Original Instructions CompactLogix 5370 L3 Controllers Catalog Numbers 1769-L30ER, 1769-L30ER-NSE, 1769-L30ERK, 1769-L30ERM, 1769-L30ERMK, 1769-L33ER, 1769-L33ERK, 1769-L33ERM, 1769-L33ERMK, 1769-L36ERM, 1769-L37ERM, 1769-L37ERMK, 1769-L38ERM, 1769-L38ERMK Topic Page Summary of Changes Install the Secure Digital Card Assemble the System Mount the System Ground the System Network Connectors and Cable Specifications...
  • Page 2 Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt. Rockwell Automation Publication 1769-IN023C-EN-P - January 2022...
  • Page 3 Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for the purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability for actual use based upon the examples shown in this publication.
  • Page 4 • This equipment must be used within its specified ratings that are defined by Rockwell Automation. • Provision must be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the peak rated voltage when applied in Zone 2 environments.
  • Page 5 The covering covers the exposed interconnections on the right side of the controller. Failure to use a protective covering could result in equipment damage or injury from electric shock. Wire the 1769 Compact I/O power supply according to the directions in the Compact I/O Expansion Power Supplies Installation Instructions, publication 1769-IN028. Rockwell Automation Publication 1769-IN023C-EN-P - January 2022...
  • Page 6 Secure DIN rail to mounting surface approximately every 200 mm (7.8 in.) and use end-anchors appropriately. Be sure to ground the DIN rail properly. See Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1,...
  • Page 7 • IEC 60068-2-2 (Test Bd, Operating Dry Heat) • IEC 6068-2-14 (Test Na, Operating Thermal Shock) Temperature, Surrounding Air, Max 60 °C (140 °F) Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description CompactLogix 5370 L3 Controller User Manual, publication 1769-UM021 Provides information on how to install, configure, program, and use CompactLogix controllers.
  • Page 8 Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, Compact I/O, CompactLogix, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.