KLV-26,32 NX400(S/B), 26,32 NX400(S/B)/S, 32,40 NX500
2-5. Standby LED Error Display and Board Replacement Order
Perform below countermeasures according to Standby LED blinking times.
Blinking times
2
3
4
5
6
7
Note:-
1: Each of the above blinking repeats 3 seconds.
2. Countermeasure is list out by priority.
Error
Main Power Error
DC_ALERT 1/ Audio Error/
Motionflow Error
Balancer Error
T-CON Error / Panel ID NVM Error
Backlight Error
Temp. Error
RM-GA018
(Replace either/all according to sequence)
1) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
2) BAA board.
1) BAA board.
2) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
3) TCON.
4) Speaker.
1) Inverter board.
2) Panel.
3) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
4) BAA board.
1) T-CON.
2) BAA board.
3) LVDS Cable.
4) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
1) Inverter board
2) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
3) BAA board.
1) BAA board.
2) Power Unit(26"), G2LE Unit(32"),
G2HE Unit(40") board.
– 6 –
Countermeasure