HMS Networks Intesis IN770AIR00 O000 Series User Manual

HMS Networks Intesis IN770AIR00 O000 Series User Manual

Mitsubishi domestic and commercial with knx, serial and ip support
Hide thumbs Also See for Intesis IN770AIR00 O000 Series:

Advertisement

Quick Links

ENGLISH
Mitsubishi domestic and commercial with KNX, Serial and IP support
IN770AIR00XO000 GATEWAY
USER MANUAL
Version 1.0.0
Publication date 2023-05-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intesis IN770AIR00 O000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HMS Networks Intesis IN770AIR00 O000 Series

  • Page 1 ENGLISH Mitsubishi domestic and commercial with KNX, Serial and IP support IN770AIR00XO000 GATEWAY USER MANUAL Version 1.0.0 Publication date 2023-05-02...
  • Page 2 The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
  • Page 3: Table Of Contents

    Mitsubishi domestic and commercial with KNX, Serial and IP support Table of Contents 1. Description and Order Codes ..................... 1 2. Licensing ..........................2 3. General Information ........................ 3 3.1. Intended Use of the User Manual ..................3 3.2. General Safety Information ....................3 3.3.
  • Page 4: Description And Order Codes

    Description and Order Codes Mitsubishi domestic and commercial with KNX, Serial and IP support 1. Description and Order Codes IN770AIR00xO000 Gateway Modbus®, KNX®, BACnet®, and Home Automation® gateway for Mitsubishi Electric® air conditioning systems ORDER CODE LEGACY ORDER CODE INMBSMIT050C000 INMBSMIT100C000 IN770AIR00xO000 INKNXMIT015C000 INKNXMIT100C000 The x stands for S, M, or L, depending on the license you have...
  • Page 5: Licensing

    Mitsubishi domestic and commercial with KNX, Serial and IP support Licensing 2. Licensing Distribution license(s) for the IN770AIR00xO000 gateway: Order Code License Maximum groups IN770AIR00SO000 Small IN770AIR00MO000 Medium NOTE The order code may vary depending on the product seller and the buyer's location. Page 2 of 42 USER MANUAL Version 1.0.0...
  • Page 6: General Information

    General Information Mitsubishi domestic and commercial with KNX, Serial and IP support 3. General Information 3.1. Intended Use of the User Manual This manual contains the main features of this Intesis gateway and the instructions for its appropriate installation, configuration, and operation. The contents of this manual should be brought to the attention of any person who installs, configures, or operates this gateway or any associated equipment.
  • Page 7 Mitsubishi domestic and commercial with KNX, Serial and IP support Admonition Messages and Symbols NOTE Additional information which may facilitate installation and/or operation. Helpful advice and suggestions. NOTICE Remarkable Information. Page 4 of 42 USER MANUAL Version 1.0.0...
  • Page 8: Overview

    Overview Mitsubishi domestic and commercial with KNX, Serial and IP support 4. Overview This document describes the available applications for this IN770AIR00xO000 gateway. IMPORTANT This document assumes that the user is familiar with these technologies. Figure 1. Integration of Mitsubishi Electric AC systems into Modbus / BACnet installations Figure 2.
  • Page 9: Inside The Package

    Mitsubishi domestic and commercial with KNX, Serial and IP support Inside the Package Figure 3. Integration of Mitsubishi Electric AC systems into Home Automation installations 4.1. Inside the Package Items included: • Intesis IN770AIR00xO000 gateway • USB Mini-B type to USB A type cable •...
  • Page 10: Gateway General Functionality

    Gateway General Functionality Mitsubishi domestic and commercial with KNX, Serial and IP support 4.3. Gateway General Functionality With this Intesis IN770AIR00xO000 gateway, you can easily integrate Mitsubishi Electric air conditioning (AC) systems into an installation based on Modbus TCP, Modbus RTU, KNX, BACnet/IP, BACnet MS/TP, or Home Automation.
  • Page 11: Hardware

    Mitsubishi domestic and commercial with KNX, Serial and IP support Hardware 5. Hardware 5.1. Mounting IMPORTANT Before mounting, please ensure that the chosen installation place preserves the gateway from direct solar radiation, water, high relative humidity, or dust. IMPORTANT Maximum mounting height: below 2 meters (6.5 feet). NOTE Mount the gateway on a wall or over a DIN rail.
  • Page 12 Mounting Mitsubishi domestic and commercial with KNX, Serial and IP support DIN rail mounting Keep the clips down in their original position. Fit the gateway’s top side clips in the upper edge of the DIN rail. Use a screwdriver or similar to pull the bottom clip down. Fit the low side of the gateway in the DIN rail and let the clip switch back to its original position, locking the gateway to the rail.
  • Page 13: Connection

    Mitsubishi domestic and commercial with KNX, Serial and IP support Connection 5.2. Connection CAUTION Disconnect all systems from the power source before manipulating and connecting them to the gateway. 5.2.1. Gateway Connectors Figure 4. General view of all gateway connectors 1.
  • Page 14 Connection Mitsubishi domestic and commercial with KNX, Serial and IP support IMPORTANT Use solid or stranded wires (twisted or with ferrule). Wire cross-section/gauge for all wire connectors: • 1 core: 0.5 to 2.5 mm (24 to 11 AWG). • 2 cores: 0.5 to 1.5mm (24 to 15 AWG).
  • Page 15: Common Connections

    Mitsubishi domestic and commercial with KNX, Serial and IP support Connection 5.2.2. Common Connections 5.2.2.1. Connecting the Gateway to the Power Supply The power supply connector is a green pluggable terminal block (3 poles) labeled as Power. IMPORTANT • Use SELV-rated NEC class 2 or limited power source (LPS) power supply. •...
  • Page 16 Connection Mitsubishi domestic and commercial with KNX, Serial and IP support NOTICE See the wiring diagram in the gateway connectors figure: General view of all gateway connectors (page 10). USER MANUAL Version 1.0.0 Page 13 of 42...
  • Page 17: Connection Procedure For Modbus

    Mitsubishi domestic and commercial with KNX, Serial and IP support Connection 5.2.3. Connection Procedure for Modbus NOTE Remember to check the Common Connections (page 12). For Modbus TCP: 1. Connect the Modbus TCP Ethernet cable to the gateway's Ethernet Port. IMPORTANT Use a straight Ethernet UTP/FTP CAT5 or higher cable.
  • Page 18 Connection Mitsubishi domestic and commercial with KNX, Serial and IP support 2. Use the supplied USB Mini-B type to A type cable to connect the gateway, through its USB port, to a PC to configure it with Intesis MAPS. NOTICE Find all you need to know about the gateway configuration and Intesis MAPS in the IN770AIR00xO000 Gateway configuration guide.
  • Page 19: Connection Procedure For Knx

    Mitsubishi domestic and commercial with KNX, Serial and IP support Connection 5.2.4. Connection Procedure for KNX NOTE Remember to check the Common Connections (page 12). 1. Connect the KNX TP communication cable to the gateway's KNX port. IMPORTANT Observe polarity. 2.
  • Page 20: Connection Procedure For Bacnet

    Connection Mitsubishi domestic and commercial with KNX, Serial and IP support 5.2.5. Connection Procedure for BACnet NOTE Remember to check the Common Connections (page 12). For BACnet/IP: 1. Connect the BACnet/IP Ethernet cable to the gateway's Ethernet Port. The correct cable to use depends on where the gateway is connected: •...
  • Page 21 Mitsubishi domestic and commercial with KNX, Serial and IP support Connection 2. Use the supplied USB Mini-B type to A type cable to connect the gateway, through its USB port, to a PC to configure it with Intesis MAPS. NOTICE Find all you need to know about the gateway configuration and Intesis MAPS in the IN770AIR00xO000 Gateway configuration guide.
  • Page 22: Connection Procedure For Home Automation

    Connection Mitsubishi domestic and commercial with KNX, Serial and IP support 5.2.6. Connection Procedure for Home Automation NOTE Remember to check the Common Connections (page 12). 1. Connect the Home Automation Ethernet cable to the gateway's Ethernet Port. IMPORTANT Use a straight Ethernet UTP/FTP CAT5 or higher cable. IMPORTANT If communicating through the LAN of the building, contact the network administrator and make sure traffic on the used port is allowed through all LAN paths.
  • Page 23: Led Indicators

    Mitsubishi domestic and commercial with KNX, Serial and IP support LED Indicators 5.3. LED Indicators Figure 5. Gateway layout Color Description Top side LED 1 (PWR) Green Power on (not programmable) LED 2 (ERR) Blinking: Hardware error LED 3 Green 485 Tx (RS485 for BACnet or Modbus) LED 4 Yellow...
  • Page 24 LED Indicators Mitsubishi domestic and commercial with KNX, Serial and IP support NOTE LEDs are hidden behind the four frontal labeled covers. These covers are assembled by pressure, so you just need to pull them to remove them. USER MANUAL Version 1.0.0 Page 21 of 42...
  • Page 25: Dip Switches

    Mitsubishi domestic and commercial with KNX, Serial and IP support DIP Switches 5.4. DIP Switches See figure: Gateway layout (page 20) 1: DIP switch A (SW A). 2: DIP switch B (SW B). Each DIP switch is dedicated to a 485 port, and its function is to activate or deactivate the termination resistor and the polarization of each port: Position Description...
  • Page 26: Push Button

    Push Button Mitsubishi domestic and commercial with KNX, Serial and IP support 5.5. Push Button Find the push button at the top side, between the KNX and the Ethernet connectors. See Figure Gateway layout (page 20) NOTE The button is hidden and only accessible using a thin object like a paper clip. Common functionality: Reset factory settings Push the button.
  • Page 27: Technical Specifications

    Mitsubishi domestic and commercial with KNX, Serial and IP support Technical Specifications 5.6. Technical Specifications Plastic, type PC (UL 94 V-0). Color: Light Grey. RAL 7035 Case Net dimensions (dxwxh): 90x106x58 mm / 3.5x4.2x2.3" Recommended space for installation (dxwxh): 130x115x100 mm / 5.1x4.5x3.9" Wall: M3 25mm (1") length screws.
  • Page 28: Dimensions

    Dimensions Mitsubishi domestic and commercial with KNX, Serial and IP support 5.7. Dimensions • Net dimensions (DxWxH) Millimeters: 90 x 106 x 58 mm Inches: 3.5 x 4.2 x 2.3" • Clear space for installation (DxWxH) Millimeters: 130 x 115 x 100 mm Inches: 5.1 x 4.5 x 3.9"...
  • Page 29: Available Applications

    Mitsubishi domestic and commercial with KNX, Serial and IP support Available Applications 6. Available Applications 6.1. Integration into Modbus Systems 6.1.1. Modbus Registers NOTICE This part is common for Modbus RTU and TCP. Functions to read Modbus registers: • 03 Read Holding Registers. •...
  • Page 30 Integration into Modbus Systems Mitsubishi domestic and commercial with KNX, Serial and IP support Register name Possible values Fan Speed (all the IC groups) 1-Set Fan Speed Mid2 Fan Speed (all the IC groups) 1-Set Fan Speed High Fan Speed (all the LOSSNAY groups) 1-Set Fan Speed Low Fan Speed (all the LOSSNAY groups) 1-Set Fan Speed High...
  • Page 31 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into Modbus Systems Register name Possible values Allow fan speed control from the local panel 0-Allow, 1-Not allow Allow timer control from the local panel 0-Allow, 1-Not allow Setback control 0-Disable, 1-Enable Minimum cool setpoint restriction 4.5 ..
  • Page 32: Integration Into Knx Systems

    Integration into KNX Systems Mitsubishi domestic and commercial with KNX, Serial and IP support 6.2. Integration into KNX Systems 6.2.1. KNX signals IMPORTANT The signals available depend on the gateway configuration and/or the unit type (AC indoor unit, Air-to-water booster unit, heat pump, etc.) To know more, refer to the IN770AIR00XO000 gateway configuration guide.
  • Page 33 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into KNX Systems Description Object function Vane position AUTO (all the groups) 1-Set auto vane; 0-Stop auto vane DPT_Switch (1bit) Vane position Swing (all the groups) 1-Set swing vane; 0-Stop swing vane DPT_Switch (1bit) Individual Temperature Setpoint (ºC) (all 5 ..
  • Page 34 Integration into KNX Systems Mitsubishi domestic and commercial with KNX, Serial and IP support Description Object function Control_Heat recovery mode LOSSNAY 1-Set heat recovery mode DPT_Switch (1bit) 1-Heat recovery mode active, 0-Heat Status_Heat recovery mode LOSSNAY DPT_Switch (1bit) recovery mode not active Control_Bypass mode LOSSNAY 1-Set bypass mode DPT_Switch (1bit)
  • Page 35 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into KNX Systems Description Object function 1-Horizontal, 2-Position-2, 3-Position-3, Status_Vane position enumerated DPT_Enumerated (1byte) 4-Position-4, 5-Vertical, Thersholds (0..30%, 31..50%, 51..70%, Control_Vane position scaling DPT_Scaling (1byte) 71..90%, 91..100%) Status_Vane position scaling Thersholds (20%, 40%, 60%, 80%, 100%) DPT_Scaling (1byte) Control_Vane position auto...
  • Page 36 Integration into KNX Systems Mitsubishi domestic and commercial with KNX, Serial and IP support Description Object function Control_Setback 1-Enable, 0-Disable DPT_Enable (1bit) Status_Setback 1-Enable, 0-Disable DPT_Enable (1bit) Control_Cool/dry/auto(upper) dual 4.5 .. 90ºC / 40 .. 194ºF DPT_Value_Temp (2byte) temperature setpoint (ºC) Status_Cool/dry/auto(upper) dual 4.5 ..
  • Page 37 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into KNX Systems Description Object function 13.013-DPT_ActiveEnergy_kWh Status_Consumption Today Cool n Wh / n kWh (4byte) 13.013-DPT_ActiveEnergy_kWh Status_Consumption Total Cool n Wh / n kWh (4byte) Table 5. Individual error code signals for indoor and outdoor units Status_Indoor Unit n error Number of the error code Controller 1 ..
  • Page 38: Integration Into Bacnet Systems

    Integration into BACnet Systems Mitsubishi domestic and commercial with KNX, Serial and IP support 6.3. Integration into BACnet Systems NOTICE You can see the Protocol Implementation Conformance Statement (PICS) document in 6.3.1. BACnet Objects NOTICE This part is common for BACnet MS/TP and BACnet/IP. Input object types: •...
  • Page 39 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into BACnet Systems Object name Possible values Object type Object instance 1-Hot_Water, 2-Heating, 3-Heating_Eco, 4- (CC[0..1]*1000)+ CXGX_Mode_C 14-Multistate Output Anti_Freeze, 5-Cooling (G[1..50]*100)+2 (CC[0..1]*1000)+ CXGX_FanSpeed_S 13-Multistate Input (G[1..50]*100)+3 The values depend on the number of fan (CC[0..1]*1000)+ speeds selected in the configuration tool: CXGX_FanSpeed_S...
  • Page 40 Integration into BACnet Systems Mitsubishi domestic and commercial with KNX, Serial and IP support Object name Possible values Object type Object instance (CC[0..1]*1000)+ CXGX_Allow_FANSPEED_Panel_S 0-Allow, 1-Not allow 3-Binary Input (G[1..50]*100)+6 (CC[0..1]*1000)+ CXGX_Allow_FANSPEED_Panel_C 0-Allow, 1-Not allow 4-Binary Output (G[1..50]*100)+6 (CC[0..1]*1000)+ CXGX_Allow_VANES_Panel_S 0-Allow, 1-Not allow 3-Binary Input (G[1..50]*100)+7...
  • Page 41 Mitsubishi domestic and commercial with KNX, Serial and IP support Integration into BACnet Systems Object name Possible values Object type Object instance (CC[0..1]*1000)+ CXGX_AutoSingle_Setpoint_C 4.5 .. 90ºC / 40 .. 194ºF 1-Analog Output (G[1..50]*100)+12 (CC[0..1]*1000)+ CXGX_HotWater_Setpoint_S 4.5 .. 90ºC / 40 .. 194ºF 0-Analog Input (G[1..50]*100)+17 (CC[0..1]*1000)+...
  • Page 42: Integration Into Home Automation Systems

    Integration into Home Automation Systems Mitsubishi domestic and commercial with KNX, Serial and IP support 6.4. Integration into Home Automation Systems 6.4.1. Home Automation Signals The following tables list all available Home Automation signals for this gateway. NOTE • SET: Command used to control the indoor unit. It is sent by the client. •...
  • Page 43: Late Configuration: Change The Gateway's Protocol

    Mitsubishi domestic and commercial with KNX, Serial and IP support Late Configuration: Change the Gateway's Protocol 7. Late Configuration: Change the Gateway's Protocol Reconfiguring the gateway with a different protocol is very easy: Connect the gateway to the PC and open the configuration tool Intesis MAPS. Select the new template you need.
  • Page 44: Error Codes

    Error Codes Mitsubishi domestic and commercial with KNX, Serial and IP support 8. Error Codes NOTE These error codes are the same for all applications. Error Code Description 65535 (-1) Communication error between the gateway and the AC unit No active error 1102 Discharge temperature high 1108...
  • Page 45 Mitsubishi domestic and commercial with KNX, Serial and IP support Error Codes 6608 M-NET transmission error 6608 M-NET without response 6831 Remote controller transmission error (reception error) 6832 Remote controller transmission error (transmission error) 6840 Transmission error with the indoor/outdoor unit (reception error) 6841 Transmission error with the indoor/outdoor unit (transmission error) Error in the inter-connection cable in the indoor/outdoor unit, indoor unit number...

Table of Contents