Instruction book
7.2
Oil and oil filter change
Warning
Procedure
1. Run the compressor until warm. Stop the compressor. Close the air outlet valve and switch off the voltage.
Depressurise the compressor by opening manual drain valve(s) (if available). Wait a few minutes and
depressurise the air receiver/oil tank (AR) by unscrewing oil filler plug (FC) just one turn to permit any
pressure in the system to escape. Also depressurize the air pipe by unscrewing the air vent plug (Fa) with
one turn.
2. Loosen the vent plug (VP) of the oil cooler and wait for 5 minutes.
3. Remove oil drain plug (DP1). Drain the oil by opening valve (Vd). Close the valve and fit the plug after
draining.
2920 7101 21
The operator must apply all relevant
Always drain the compressor oil at all drain points. Used oil left in the compressor can
contaminate the oil system and can shorten the lifetime of the new oil.
Never mix lubricants of different brands or types as they may not be compatible and the
oil mix will have inferior properties. A label, indicating the type of oil filled ex-factory, is
stuck on the air receiver/oil tank.
Oil system components
Safety
precautions.