Download Print this page

Troubleshooting The Pump - Fimco HIGH-FLO PRO Series Owner's Manual

12 volt, 2.2 gpm, 100 psi diaphragm pump

Advertisement

Replacement Pump:
5281325
DO
Clean and rinse your pump after each use with Fimco Tank
Neutralizer
Winterize your pump or sprayer by rinsing, draining and
running RV Antifreeze through it before storing for the winter.
Use clean water for your spray mixture
Store inside a building when not in use.

Troubleshooting the Pump:

Motor does not run:
Check for loose wiring connection(s).
Make sure the 'ON/OFF' switch in the lead wire assembly
is in the 'ON' position. "I" is the 'ON' position and 'O' is
the 'OFF' position.
Check for defective pressure switch. Refer to instructions
on next page.
Check for low voltage at the power supply.
Pump does not prime:
Check for air leaks in supply line.
Check for debris in the check valve assembly.
Check for defective check valve.
Check for clogged strainer/filter.
Check for cracks in the pump housing.
Check for empty product supply.
Low Pressure/Low Flow:
Check for leaks in the discharge line.
Check for restriction in the discharge line.
Check for debris in nozzle orifice.
Check for clogged strainer.
Check for proper voltage—try another 12-volt battery.
Page 4
Pump Model: 5151075
Available Replacement Parts
DON'T
Use to pump bleach.
Use to pump gasoline or kerosene
Leave your pump sit with spray mixture in it for extended
periods
Use dirty or unfiltered water for spraying
Pulsating flow (surging):
Suction leak may cause pump to surge.
Spray wand is adjusted for a small or fine spray
pattern.
Slightly open bypass (if applicable) to overcome.
Check for defective pressure switch.
Check for leaks in the discharge line.
Check for restriction in the discharge line.
Check for debris in nozzle orifice.
Discharge hose may be too long.
Check for clogged strainer.
Motor continues to run after discharge is shut off:
Check for empty product supply.
Check for open bypass valve. (if equipped)
Check for low voltage.
Check for leak in discharge line.
Check for defective pressure switch.
System has leaks.

Advertisement

loading
Need help?

Need help?

Do you have a question about the HIGH-FLO PRO Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

High-flo hfp-2.252813255151075