Permanent hearing damage may occur when headphones are used at high volume levels for long periods of time. Headphones of the Sennheiser brand sound exceptionally good even at low and medium volume levels and provide excellent speech intelligibility.
Page 3
70 °C/158 °F. Avoid exposure to sunlight and do not throw the product / rechargeable batteries into fire. Switch rechargeable battery-powered products off after use. When not using the product / rechargeable batteries for extended periods of time, charge them regularly (about every three months). RS 2000...
Page 4
Sonova Consumer Hearing GmbH does not accept liability for damage arising from misuse or improper use of this product and its attachments/accessories. Before putting the product into operation, please observe the respective country-specific regulations. RS 2000...
Quick guide Online you can find: • this detailed instruction manual and additional information (www.sennheiser-hearing.com/download). • a list of accessories on the RS 2000 product page at www.sennheiser-hearing.com (to purchase online or con- tact your local Sonova Consumer Hearing partner: www.sennheiser-hearing.com/service-support).
... is connected to the transmitter, the rechargeable battery is almost empty..is not connected to the transmitter or cannot connect to the transmitter..is not connected to the transmitter or cannot connect to the transmitter, the rechargeable battery is almost empty. RS 2000...
Analog 3.5 mm In audio ing magnets input (marked blue) for connecting an analog audio source (3.5 mm jack socket) Transmitter status LED The transmitter..is in standby mode..and the stethoset receiver are connected. RS 2000...
Page 8
Putting the RS 2000 into operation Putting the RS 2000 into operation Setting up the transmitter Place the transmitter near your audio source. Separate the transmitter from other wireless devices in the room by at least 50 cm/20" to avoid interference.
Putting the RS 2000 into operation Connecting the transmitter to an audio source You can connect the transmitter to an analog audio source (e.g. a TV and a stereo hi-fi system). You can also refer to the beginner’s video guides on how to connect your digital wireless headphone system to a www.sennheiser-hearing.com/how-to-videos...
Page 10
Putting the RS 2000 into operation Connection possibility A: 3.5 mm jack socket (analog) Connect the stereo audio cable to the blue Analog 3.5 mm audio input (3.5 mm jack socket) of the transmitter and to the 3.5 mm headphone socket of your audio source.
Page 11
Putting the RS 2000 into operation Connection possibility B: RCA sockets (analog) Plug the RCA adapter* onto the stereo audio cable. Connect the stereo audio cable to the blue 3.5 mm jack socket of the transmitter. Connect the RCA connectors to the RCA sockets (mostly labeled “AUDIO OUT”...
Putting the RS 2000 into operation Connecting the transmitter to the power supply system Connect the connector of the power supply unit to the yellow socket of the transmitter. Select a suitable country adapter and slide it onto the power supply unit until it clicks audibly into place.
Putting the RS 2000 into operation Charging the stethoset receiver’s rechargeable battery A complete charging cycle takes about 3 hours. Before using the receiver for the first time, charge its rechargeable battery for a complete charging cycle without interruption. Receiver...
Using the RS 2000 Using the RS 2000 Switching the wireless headphone system on WARNING Vol + Danger due to high volume levels! This receiver allows you to set higher volumes than conven- tional devices. Constant high-volume use can cause hearing Vol - damage.
Using the RS 2000 Switching the wireless headphone system off Take the stethoset receiver off so that the ear bows fold inwards. The stethoset receiver automatically switches off after Receiver status 3 seconds. The LED goes off. The transmit- ter automatically switches off (standby) when there is no Transmitter status stethoset receiver connected.
Using the RS 2000 Wearing the stethoset receiver Wear the stethoset receiver so that it hangs freely from your ears and rests lightly on your chest. When putting the stethoset receiver on, observe the (left) and (right) markings on the rear of the ear bows. The volume buttons face away from your body to facilitate ease of use.
Using the RS 2000 VOLUME VOLUME Adjusting the balance The balance buttons allow for left/right volume adjustment. Adjust the balance so that you hear equally well with both ears. Balance Press the buttons on the right and left side of the stethoset receiver to gradually increase or reduce the volume for your right or left ear.
Page 18
Cleaning and maintaining the RS 2000 Cleaning and maintaining the RS 2000 CAUTION Liquids can damage the electronics of the product! Liquids entering the housing of the product can cause a short- circuit and damage the electronics. Keep all liquids far away from the product.
Cleaning and maintaining the RS 2000 Replacing the stethoset receiver’s rechargeable battery The BAP 800 rechargeable battery of the stethoset receiver is compactly built into the receiver housing and does not have to be replaced or removed. If the operating time of the stethoset receiver decreases dras-...
5 seconds until the LED flashes green rapidly. Then release the volume buttons +/–. Receiver status Once pairing is completed, the LED and the Transmitter status LED light up green. The audio transmis- sion starts. 20 | RS 2000...
If the LED on the charging adapter flashes red and green, a charging error/battery error has occurred. In this case, dis- connect the charging adapter from the stethoset receiver. More information on the rechargeable battery can be found on page 19. RS 2000 | 21...
Page 22
Sound too low Increase the volume of the analog The volume of the analog audio audio source to at least a medium – source is adjusted too low. level (approx. 1 V 22 | RS 2000...
If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions, visit the RS 2000 product page at www.sennheiser-hearing.com. There you will find a current list of frequently asked questions (FAQ).
Page 24
Take off the stethoset receiver before re-entering the range of the transmitter. When you re-enter the range of the transmitter, the transmit- ter automatically switches on again and the connection is re- established. 24 | RS 2000...
Specifications Specifications System, model: RS 2000 Transmission frequency 2.4 – 2.4835 GHz Modulation 8-FSK Digital typ. 85 dBA at 1 V Signal-to-noise ratio RF output power max. 10 dBm Audio latency < 60 ms Range up to 50 m (line of sight)
Page 26
Nominal output voltage 5 V Nominal output current 1 A operation: 0 °C to +40 °C Temperature range storage: –25 °C to +70 °C operation: 10 to 80 % Relative air humidity (non-condensing) storage: 10 to 90 % 26 | RS 2000...
Recycle electrical and electronic equipment and batteries/rechargeable batteries at the end of their operational lifetime in order to make contained recycla- ble materials usable and to avoid littering the environment. RS 2000 | 27...
Page 28
Sonova Consumer Hearing partner. You can also return electrical or electronic equipment to distributors who have a take-back obligation. Herewith you make an important contribution to the protection of the envi- ronment and public health. 28 | RS 2000...