8
NX-592E-GSM Wireless Gateway
Installation Manual
Wiring connections
To wire the module, do the following:
1. Remove panel AC power and disconnect the backup battery.
CAUTION: To prevent damage to the panel or module, you must remove panel AC power and disconnect the backup
battery prior to changing any wire connections.
2. Wire the module to the panel bus and power terminals (see Figure 4 and Table 3).
Figure 4. Wiring connections
Table 3.
Terminal descriptions
Terminal
POS
COM
DATA
POS
Gateway
Panel
KP POS
Description
Connect to the KP POS terminal of the NetworX panel
Connect to the KP COM terminal of the NetworX panel
Connect to the KP DATA terminal of the NetworX panel
COM
DATA
KP COM
KP DATA