HF9624 4G PLC Remote Control Serial Server User Manual HF9624 4G PLC Remote Control Serial Server User Manual V 1.0 Overview of Characteristic MIPS MCU with 16MB Flash and 64MB SRAM. Run with Linux OpenWrt Support 4G/3G/GPRS, FDD-LTE, TDD-LTE, WCDMA, TD-SCDMA, CDMA2000, CDMA 1X/EVDO, GSM900/1800 ...
Page 2
HF9624 4G PLC Remote Control Serial Server User Manual Support 802.11bgn Wi-Fi to 4G/3G/GPRS Support APN network Support VPN(PPTP, L2TP, L2TP+IPSEC) Support TCP/IP/Telnet/Modbus TCP Protocol, support TLS/AES/DES3 enrtyption Support Router or Bridge Network Working Mode.
HF9624 4G PLC Remote Control Serial Server User Manual TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS ................3 LIST OF FIGURES ..........................4 LIST OF TABLES ..........................5 PRODUCT OVERVIEW ......................6 1.1. General Description ......................6 1.2.
HF9624 4G PLC Remote Control Serial Server User Manual 1. PRODUCT OVERVIEW 1.1. General Description The 4G serial server device HF9624 provides protocol conversion among RS232/RS485/RS422 interface, Ethernet/Wi-Fi and 3G/4G,which can meet the solutions for serial/network transmission of industrial products. The HF9624 integrates 4G/3G,Wi-Fi, Ethernet, high-speed serial port, RS232/RS485/RS422 interfaces, and it is based on Ecos operation system and contain webpage, TCP/IP stack.
Page 7
HF9624 4G PLC Remote Control Serial Server User Manual Ethernet Port 2 RJ45 Port Number 1 WAN/LAN switchable 1 LAN Interface 10/100 Base-T Auto-Negotiation Standard Anti-reverse Power Protection Static: 8KV Contact Discharge, 15KV Air Discharge Surge: Difference-mode 4KV, Common-mode 6KV...
Page 8
HF9624 4G PLC Remote Control Serial Server User Manual R99: CSD Transmission Rate:9.6Kbps/14.4Kbps GPRS: Support GPRS multi-slot class 12 GSM/GPRS/EDG Code Method:CS-1/CS-2/CS-3/CS-4 EDGE: Support EDGE multi-slot class 12 Support up/downstream Code Method: CS1-4,MCS1-9 Serial Port Port Number RS232: DB9 Interface RS485/RS422: 5.08mm connector...
HF9624 4G PLC Remote Control Serial Server User Manual 2. HARDWARE INTRODUCTION The HF9624 unit is a complete solution for serial port device connecting to network. This powerful device supports a 10/100BASE-T Ethernet connection, a full TCP/IP protocol stack, and multiple encryption method to ensure confidentiality.
HF9624 4G PLC Remote Control Serial Server User Manual Function Name Description Interface 4G SMA Antenna Connect to 4G antenna Interface DC/Power Input DC Power 9~36V Input Internal Power Supply Indicator Indicator Power On:Power is OK Off:Power is NG UART Port 1~2 data transfer Indicator...
HF9624 4G PLC Remote Control Serial Server User Manual Table3. RS232 Pin Interface Pin Number Name Description Receive Data Send Data Request to Send Clear to Send 2.3. RS485 Interface RS485 use two wire links, A(DATA+), B(DATA-). Connect A(+) to A(+), B(-) to B(-) for communication.
Description Transfer Data+ Transfer Data- Receive Data+ Transformer Tap Voltage PHY-VCC Transformer Tap Voltage PHY-VCC Receive Data- None Connect N.C. None Connect N.C. 2.6. Mechanical Size The dimensions of HF9624 are defined as following picture (mm): http://www.iotworkshop.com - 12 -...
HF9624 4G PLC Remote Control Serial Server User Manual Figure 6. Mechanical Dimension 2.7. Rail Mounting We support to provide rail for mounting as the following picture. Figure 7. Rail Mounting http://www.iotworkshop.com - 13 -...
3.1. Basic Network Protocol The HF9624 device uses the IP address for network communications. If uses the TCP to assure that no data is lost or duplicated. If use UDP to assure that data can be fast and effective to Destination address.
HF9624 4G PLC Remote Control Serial Server User Manual HF9624 can construct a wireless network as AP. All the STA devices will consider the AP as the centre of the wireless network. The mutual communication can be transponded by AP. If 4G network connects well, PLC device will send data to public server shown as follow: Figure 9.
HF9624 4G PLC Remote Control Serial Server User Manual Figure 10. Configure Wi-Fi Parameter 3.2.6. Webpage Configuration Use PC to connect with HF9624 through its AP hotspot or Ethernet connection. Input the default IP(10.10.100.254, default username and password: admin/admin) to login the webpage to configure the parameter.
HF9624 4G PLC Remote Control Serial Server User Manual Figure 12. WAN/LAN Switch Figure 13. PC Connect to LAN 3.3.1. Ethernet Port with Wi-Fi http://www.iotworkshop.com - 17 -...
HF9624 4G PLC Remote Control Serial Server User Manual Figure 14. Ethernet Interface Function HF9624 generates a central network. Each devices’ IP address is working under the same segment with HF9624(default as 10.10.100.XXX, can be modified). Devices can communicate mutually, and the devices above can visit public resource normally.
HF9624 4G PLC Remote Control Serial Server User Manual APPENDIX B: CONTACT INFORMATION ------------------------------------------------------------------------------------------------------------ Address: Room 1002,Building 1,No.3000,Longdong Avenue,Pudong New Area,Shanghai,China,201203 Web: www.iotworkshop.com www.hi-flying.com Contact: Sales: sales@iotworkshop.com Support: support@iotworkshop.com Service: service@iotworkshop.com Business: business@iotworkshop.com ---------------------------------------------------------------------------- ------------------------------- For more information about IOTworkshop modules, applications, and solutions, please visit our web site www.iotworkshop.com...
Need help?
Do you have a question about the HF9624 and is the answer not in the manual?
Questions and answers