Brivo ACS6100
Installation Manual
Legal Disclaimers ............................................................................ 2
Introduction ..................................................................................... 4
Verify client site is ready for installation ...................................... 6
Verify shipping contents ................................................................ 7
Planning the installation ................................................................ 9
Follow safety precautions ............................................................ 11
Assemble and mount chassis ...................................................... 12
ACS6000 control panel tamper switches ................................... 17
Establish CAN Bus wiring ............................................................. 21
Wire doors ..................................................................................... 24
Wire OSDP Readers ...................................................................... 27
Wire input output boards ............................................................ 33
Mount and connect the Wi-Fi antenna ....................................... 34
Ground the chassis ....................................................................... 35
Power up the control panel ......................................................... 36
Connect the LAN to the main control board ............................. 38

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACS6100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brivo ACS6100

  • Page 1: Table Of Contents

    Brivo ACS6100 Installation Manual Legal Disclaimers ................2 Introduction Introduction ..................4 Understand the function of the B-ACS6000-MBE/MBS ....6 Understand B-ACS6000-MBE/MBS product compatibility ..6 Verify client site is ready for installation ........6 Pre-Installation Procedures Verify shipping contents ..............7 Planning the installation ..............
  • Page 2: Legal Disclaimers

    L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 3 Brivo Systems LLC. The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems LLC. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States.
  • Page 4: Introduction

    B-ACS6000-MBE/MBS Control Panel at client sites. This version of the manual is also intended for IT personnel, who should use it in conjunction with the Brivo Panel Networking Admin Interface Guide or Brivo Onsite Administrator’s Manual. It may be used by dealers and their sales professionals to help them conduct pre-sales, and to provide client support during the installation process.
  • Page 5 Panel Networking Admin Interface Guide • Brivo Onsite Administrator’s Manual • Approved Reader Compatibility List • Brivo Cellular Network Router Configuration Guide • Technical Support: 1-866-BRIVO-4-U • www.brivo.com © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 6: Understand The Function Of The B-Acs6000-Mbe/Mbs

    OSDP readers using RS-485. A current list of compatible readers and keypads is maintained by Brivo. If you have a specific model of reader or keypad that you want to verify is compatible, please contact Technical Support at 1-866-BRIVO-4-U.
  • Page 7: Verify Shipping Contents

    For Brivo Access accounts, make sure the account has been created and the control panel is registered through Brivo. If the control panel has not been registered by the dealer, the installer may either contact Brivo Technical Support for assistance or simply register the panel directly.
  • Page 8 If additional INPUT OUTPUT BOARDs have been ordered with the control panel, locate and check the contents of each INPUT OUTPUT BOARD (B-ACS6100-IO) Kit. There may be up to 14 of these kits, and each should contain the following parts.
  • Page 9: Planning The Installation

    An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be used in any circumstance that uses contact closure to track change of status. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 10 Follow manufacturer guidelines for each keypad and reader. Place each chassis within 500 feet of its associated electronic strike or latch. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 11: Follow Safety Precautions

    UPS (Uninterruptible Power Supply) between the AC Mains and the transformer. WARNING: Humidity Do not install the control panel in an area that could experience humidity greater than 85 percent non-condensing. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 12: Assemble And Mount Chassis

    Install a user provided tamper switch in the chassis by removing the hex collar, seating the switch inside the provided mounting bracket, and reattaching and tightening the hex collar. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 13 Brivo ACS6100 Installation Manual ACS6000 MAIN CONTROL BOARD and ACS6100 Door Board and ACS6100 Input/Output Board switch locations Specific switch functionality is discussed later in the installation manual. Figure 1 - ACS6000 MAIN CONTROL BOARD Switch Locations Figure 2 - ACS6100 DOOR BOARD Switch Locations Figure 3 - ACS6100 INPUT OUTPUT BOARD Switch Locations ©...
  • Page 14 Brivo ACS6100 Installation Manual ACS6000 MAIN CONTROL BOARD SW 7 Switch Bank Figure 4 - ACS6000 SW 7 Switch Bank Location Figure 5 - ACS6000 SW 7 Switch Settings © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 15 Enabled: MCU Full Debug SW 7-7 Diagnostic Disabled: MCU Standard Debug Enabled: Wi-Fi can be used if configured SW 7-8 Wi-Fi Disabled: Wi-Fi cannot be used at all, even if configured © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 16: Connect The Main Control Board And All Expansion Boards

    Connect the MAIN CONTROL BOARD and all expansion boards to a power supply board IMPORTANT NOTE: If you are mounting the new B-ACS6100-DB DOOR BOARDs or B-ACS6100-IO INPUT/OUTPUT BOARDs in an ACS6000 or ACS6008 chassis, an adapter plate (B-ACS6100-ADPL) is required.
  • Page 17: Acs6000 Control Panel Tamper Switches

    Do not power electronic strikes and latches with the battery (or other power source) used to power the control panel. Doing so will cause damage to the Brivo control panel. Use only a UL/MET listed burglar alarm or access control system to power electronic strikes and latches.
  • Page 18 NOTE: If a chassis has two or more boards, connect the tamper switch to the upper right board. NOTE: If the tamper switch is not going to be used, leave the supplied jumper on this connector to keep the circuit closed. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 19: Connect The Battery Leads To The Power Supply

    To maintain MET compliance, the unit must be powered by a UL 294, UL 62368-1 or UL60950-1 Listed power supply capable of supplying 16.5VAC, 3.03A, 60Hz or 19VDC, 2.63A to the power supply board. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 20 Brivo B-ACS6100L-E/S supply board PSBs inside of the chassis) (Qty 2) 19 VDC (Secondary) 2.63A (DC) 16.5 VAC (Secondary) 3.03A (RMS) © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 21: Establish Can Bus Wiring

    If there are expansion boards in the control chassis, connect them to the MAIN CONTROL BOARD. Figure 13 - Connect Expansion Board to MAIN CONTROL BOARD If there are expansion chassis, in each chassis connect the expansion boards as shown below. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 22 Wire E3, E4, E5, and E6 together as described above in Figure 11. • Wire E1 in the Control Chassis to E3 in the expansion chassis. • Wire E2 to the MAIN CONTROL BOARD. Figure 15 - CAN Bus Configuration © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 23 Address the CAN BUS ADDRESS switch (SW1). The silkscreen next to SW1 shows how to position the switches appropriately. Switch positions for all address values are shown in the diagram below. Figure 16 - CAN BUS ADDRESS Switches © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 24: Wire Doors

    NOTE: Output Ratings for the B-ACS6000-MBE/MBS MAIN CONTROL BOARD • Two (2) reader ports, 12V, 350mA each • Two (2) selectable wet contacts, 12VDC, 350mA each • Four (4) dry contacts are 28VDC, 6A each © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 25 Brivo ACS6100 Installation Manual Figure 18 - Wire DOOR BOARD NOTE: Output Ratings for the B-ACS6100-DB Door Board • Two (2) reader ports, 12V, 500mA for each reader. • Four (4) relays on the Door Board. The ratings are 28VDC, 3A each.
  • Page 26 Wiegand wiring instructions below. For OSDP Readers, refer to OSDP wiring instructions below. NOTE: Wiegand readers use a 5V signaling level and Brivo hardware is compliant with 5V Wiegand readers. Any reader that claims to be Wiegand but does not use 5V signaling is not compatible with Brivo hardware.
  • Page 27: Wire Osdp Readers

    2 nodes. If the B-ACS6000-MBE control panel is being used as one end of the RS-485 bus, be sure to put the appropriate switch in the Enabled position. NOTE: Brivo recommends using Half-Duplex mode for OSDP readers. Most commercially available OSDP readers operate in Half-Duplex mode.
  • Page 28 IMPORTANT NOTE: Allegion RSI functionality is supported on Door Node 1 only of the MAIN CONTROL BOARD. Door Node 2 does NOT support Allegion RSI functionality, nor do the B-ACS6100-DB DOOR BOARDS. On B-ACS6100- DB DOOR BOARDS, RS-485 is only supported for OSDP readers.
  • Page 29 HDX position. For Door 2, put the FDX/HDX Door 2 switch in the HDX position. Figure 22 - RS-485 Full Duplex/Half Duplex Switch Locations for Doors 1 and 2 © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 30 Door 1, put the Door 1 Wet/Dry Select Switch in the Dry position. To enable dry mode for Door 2, put the Door 2 Wet/Dry Select Switch in the Dry position. Figure 24 - ACS6000 Wet/Dry Door Contact Switches for Doors 1 and 2 © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 31 Connect the wire to the GND terminal. This is the standard Ground circuit for OSDP readers using RS-485. Connect the wire to the 12VDC terminal. This provides +12VDC to power OSDP readers using RS-485. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 32 Use the wire recommended by the manufacturer of the electric strike or latch. If no wire is recommended, use a minimum of 18 AWG wire with sufficient strands for the specific electronic strike or latch. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 33: Wire Input Output Boards

    Brivo ACS6100 Installation Manual Wire INPUT OUTPUT BOARDs Figure 26 - Wire INPUT OUTPUT BOARD NOTE: Output Ratings for the B-ACS6100-IO Input Output Board • Eight (8) relays on the I/O Board. The ratings are 28VDC, 3A each. An INPUT OUTPUT BOARD has 8 output relays and 8 inputs. The 8 inputs are located on the bottom of the INPUT OUTPUT BOARD and the 8 outputs are located along the top.
  • Page 34: Mount And Connect The Wi-Fi Antenna

    DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A MET LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES.
  • Page 35: Ground The Chassis

    Use 18 AWG or larger solid wire to connect the chassis to a suitable earth ground. The ground contact point is in the lower panel area, near the hinge for the door and in front of the power supply. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 36: Power Up The Control Panel

    This process may take several minutes, so do not disconnect or cut power to your B-ACS6000-MBE during this process. If you encounter any difficulties, please contact Brivo Technical Support at 866- 274-8648, Ext 2 or email customercare@brivo.com.
  • Page 37 NOTE: A steady light is an indication of a problem, just as much as no light is. If ALL power indicators are correct, attach the back-up battery and check that ALL indicators remain the same. © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...
  • Page 38: Connecting A Laptop To The Main Control Board Admin Port

    Figure 34 - Connect LAN to MAIN CONTROL BOARD Connect the LAN to the MAIN CONTROL BOARD according to the instructions in the Panel Networking Admin Interface Guide (or Brivo Onsite Administrator’s Manual). The LAN port is a 10/100/1000 Ethernet interface with an RJ45 jack for connecting the MAIN CONTROL BOARD to a Local Area Network in order for it to gain connectivity to ©...
  • Page 39 However, make certain that the default OSDP reader address matches the OSDP address used when assigning the reader in Brivo. Revision Table Version Date Author Content 08/27/2021 Original document 11/01/2021 LMW/RC/ Updates and corrections RTM/TRN 08/01/2022 Added Wiegand voltage warning © 2022 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS6100 Installation Manual...