Brivo ACS6100 Installation Manual Legal Disclaimers ................2 Introduction Introduction ..................4 Understand the function of the B-ACS6000-MBE/MBS ....6 Understand B-ACS6000-MBE/MBS product compatibility ..6 Verify client site is ready for installation ........6 Pre-Installation Procedures Verify shipping contents ..............7 Planning the installation ..............
Page 3
Brivo Systems LLC. The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems LLC. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States.
B-ACS6000-MBE/MBS Control Panel at client sites. This version of the manual is also intended for IT personnel, who should use it in conjunction with the Brivo Panel Networking Admin Interface Guide or Brivo Onsite Administrator’s Manual. It may be used by dealers and their sales professionals to help them conduct pre-sales, and to provide client support during the installation process.
OSDP readers using RS-485. A current list of compatible readers and keypads is maintained by Brivo. If you have a specific model of reader or keypad that you want to verify is compatible, please contact Technical Support at 1-866-BRIVO-4-U.
For Brivo Access accounts, make sure the account has been created and the control panel is registered through Brivo. If the control panel has not been registered by the dealer, the installer may either contact Brivo Technical Support for assistance or simply register the panel directly.
Page 8
If additional INPUT OUTPUT BOARDs have been ordered with the control panel, locate and check the contents of each INPUT OUTPUT BOARD (B-ACS6100-IO) Kit. There may be up to 14 of these kits, and each should contain the following parts.
Connect the MAIN CONTROL BOARD and all expansion boards to a power supply board IMPORTANT NOTE: If you are mounting the new B-ACS6100-DB DOOR BOARDs or B-ACS6100-IO INPUT/OUTPUT BOARDs in an ACS6000 or ACS6008 chassis, an adapter plate (B-ACS6100-ADPL) is required.
Do not power electronic strikes and latches with the battery (or other power source) used to power the control panel. Doing so will cause damage to the Brivo control panel. Use only a UL/MET listed burglar alarm or access control system to power electronic strikes and latches.
Page 25
Brivo ACS6100 Installation Manual Figure 18 - Wire DOOR BOARD NOTE: Output Ratings for the B-ACS6100-DB Door Board • Two (2) reader ports, 12V, 500mA for each reader. • Four (4) relays on the Door Board. The ratings are 28VDC, 3A each.
Page 26
Wiegand wiring instructions below. For OSDP Readers, refer to OSDP wiring instructions below. NOTE: Wiegand readers use a 5V signaling level and Brivo hardware is compliant with 5V Wiegand readers. Any reader that claims to be Wiegand but does not use 5V signaling is not compatible with Brivo hardware.
2 nodes. If the B-ACS6000-MBE control panel is being used as one end of the RS-485 bus, be sure to put the appropriate switch in the Enabled position. NOTE: Brivo recommends using Half-Duplex mode for OSDP readers. Most commercially available OSDP readers operate in Half-Duplex mode.
Page 28
IMPORTANT NOTE: Allegion RSI functionality is supported on Door Node 1 only of the MAIN CONTROL BOARD. Door Node 2 does NOT support Allegion RSI functionality, nor do the B-ACS6100-DB DOOR BOARDS. On B-ACS6100- DB DOOR BOARDS, RS-485 is only supported for OSDP readers.
Brivo ACS6100 Installation Manual Wire INPUT OUTPUT BOARDs Figure 26 - Wire INPUT OUTPUT BOARD NOTE: Output Ratings for the B-ACS6100-IO Input Output Board • Eight (8) relays on the I/O Board. The ratings are 28VDC, 3A each. An INPUT OUTPUT BOARD has 8 output relays and 8 inputs. The 8 inputs are located on the bottom of the INPUT OUTPUT BOARD and the 8 outputs are located along the top.
DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A MET LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES.
This process may take several minutes, so do not disconnect or cut power to your B-ACS6000-MBE during this process. If you encounter any difficulties, please contact Brivo Technical Support at 866- 274-8648, Ext 2 or email customercare@brivo.com.