How Should The T1 Time Register (T1R) Be Set To Detect A T1 Error; Can The Receive Pool For Raw Cells Be Shared With The Receive Pool For Aal-5; Pools 0 To 7 Are Allocated As The Receive Pools For Raw Cells. Can All The Pools From 0 To; Be Used For Receiving Raw Cells, Or Can Only One Of The Pools From 0 To 7 Be Used - NEC mPD98409 Q&A

Neascot-s40c atm light sar controller
Table of Contents

Advertisement

CHAPTER 8 RECEPTION
Q.8.7

How should the T1 time register (T1R) be set to detect a T1 error?

A.8.7
The setting of the T1R register should be the system clock time (BUSCLK input) × 64K. For example, where T1R
= 5, the time required to detect a T1 error is 320K clocks (about 9.8 ms where BUSCLK = 33 MHz).
Reference: µ PD98409 User's Manual 5.5.5 (3) T1 timer (reassembly timer)
Q.8.8

Can the receive pool for Raw cells be shared with the receive pool for AAL-5?

A.8.8
No. Separately set the receive pools for Raw cells and AAL-5.
Reference: µ PD98409 User's Manual 5.5.5 (2) Storing receive data
Q.8.9
Pools 0 to 7 are allocated as the receive pools for Raw cells. Can all the pools from 0 to 7 be used for receiving
Raw cells, or can only one of the pools from 0 to 7 be used?
A.8.9
All the pools from 0 to 7 can be used for receiving Raw cells.
Reference: µ PD98409 User's Manual 5.5.2 (3) Pool storing raw cell
Q.8.10
What is the Alert level of a receive pool descriptor? Are the settings and interrupts of the Alert level valid for a
Raw cell pool?
A.8.10
The settings and interrupts of the Alert level are only valid for the AAL-5 pool. This function is invalid for the Raw
cell pool, and in the µ PD98409, values set in the Alert level field are ignored.
Reference: µ PD98409 User's Manual 5.5.2 (3) Pool storing raw cell
30