Samsung AC TN4FEC Series Installation Manual

Hide thumbs Also See for AC TN4FEC Series:

Advertisement

Quick Links

Air conditioner
Installation manual
AC***TN4FEC
Thank you for purchasing this Samsung air conditioner.
Before operating this unit, please read this manual carefully and retain it for future
reference.
DB68-09222A-00

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AC TN4FEC Series

  • Page 1 Air conditioner Installation manual AC***TN4FEC Thank you for purchasing this Samsung air conditioner. Before operating this unit, please read this manual carefully and retain it for future reference. DB68-09222A-00...
  • Page 2: Table Of Contents

    Contents Safety Information Installation Procedure Step 1 Checking and preparing accessories Step 2 Choosing the installation location Step 3 Optional: Insulating the body of the indoor unit Step 4 Installing the indoor unit Step 5 Purging inert gas from the indoor unit Step 6 Cutting and flaring the pipes Step 7 Connecting the assembly pipes to the refrigerant pipes Step 8 Performing the gas leak test...
  • Page 3: Safety Information

    Safety Information WARNING CAUTION WARNING General information WARNING Installing the unit WARNING IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. English...
  • Page 4 Safety Information Power supply line, fuse or circuit breaker WARNING Do not install the air conditioner in following places. – – Step 14 Optional: Extending the power cable CAUTION Make sure that you earth the cables. Install the circuit breaker. Make sure that the condensed water dripping from the drain hose runs out properly and safely.
  • Page 5: Installation Procedure

    Installation Procedure Step 1 Checking and preparing Step 2 Choosing the installation accessories location Installation location requirements Installation template (1) Dimension gauge (1) Drain hose (1) Clamp (1) Insulation pipe CAUTION Insulation drain hose (1) (Liquid side (1), gas side (1)) Cable-tie (6) Installation manual (1) User manual (1)
  • Page 6 Installation Procedure Indoor unit dimensions Category Square panel Circular panel 1050 1000 Front Ceiling opening dimension 960 (950 - 960) Drain hose Refrigerant connector pipe Large+, Large Wire insert hole Drain hose Refrigerant connector pipe Small Wire insert hole ø100 Common Square panel Circular panel...
  • Page 7 Model Chassis Net dimension (W x H x D) Net weight Liquid pipe connection Gas pipe connection Drain hose connection (Unit: mm) 1050 Inspection hole Refrigerant pipe Indoor unit display Inspection hole Connection part of the ø1010 to 1020 drain hose Ceiling opening Category Recessed installation...
  • Page 8: Step 3 Optional: Insulating The Body Of The Indoor Unit

    Installation Procedure CAUTION NOTE Indoor unit type and models Dimensions Step 4 Installing the indoor unit Step 3 Optional: Insulating the body of the indoor unit NOTE English...
  • Page 9 Ceiling support Refrigerant pipe Indoor unit Inspection hole display CAUTION Inspection hole Refrigerant pipe CAUTION Indoor unit display Inspection hole Concrete Hole in anchor Insert Pad stopper Hole in plug Bracket English...
  • Page 10: Step 5 Purging Inert Gas From The Indoor Unit

    Installation Procedure Step 6 Cutting and flaring the pipes Pipe cutter Ceiling Indoor unit Pipe Oblique Rough Burr For the recessed installation Gauge of of the square panel: 11.5 mm dimensions For the recessed installation of the circular panel: 41.5 mm Step 5 Purging inert gas from the indoor unit R 0.4 to 0.8 mm...
  • Page 11: Step 7 Connecting The Assembly Pipes To The Refrigerant Pipes

    Outer Diameter (mm) NOTE Step 6 Cutting Uneven Damaged Cracked Correct Inclined and flaring the pipes Thickness Surface Step 7 Connecting the assembly pipes to the refrigerant pipes There are two refrigerant pipes of different diameters : CAUTION Spanner Torque wrench Union Flare nut...
  • Page 12: Step 8 Performing The Gas Leak Test

    Installation Procedure Step 8 Performing the gas leak test CAUTION CAUTION Gas side Insulator Liquid side Step 9 Insulating the refrigerant pipes Hanger Additional insulation No gap Refrigerant pipe insulation a x 3 NOTE Insulation cover pipe Insulation pipe Indoor unit Be sure to overlap the insulation.
  • Page 13: Step 10 Installing The Drain Hose And Drain Pipe

    Step 10 Installing the drain hose and Insulation type (heating/cooling) drain pipe Standard High Pipe size humidity Pipe Remarks (Less than (mm) 30°C, (Over 30°C, 85%) 85%) EPDM, NBR <Geological condition> <Operation purpose condition> Drain socket Metal clamp Drain hose <Building construction condition>...
  • Page 14 Installation Procedure CAUTION Check that the indoor unit is level with the ceiling by using the leveller. Support pieces Air ventilation 1 to 1.5 m 1/100 or more Ceiling Ceiling Be horizontal Indoor unit 300 mm or less 20 mm or more Band joint Flexible hose Drain hose...
  • Page 15: Step 11 Performing The Drainage Test

    CAUTION NOTE Full thread bolt hanger 1000 to 1500 mm Main air vent Individual air (must be installed) vent 200 mm or more 300 to 550 mm Centralized horizontal drain pipe Main drain pipe (more than 1/100 slope) Step 11 Performing the drainage test Cool CAUTION Cool...
  • Page 16: Step 12 Optional: For The Installation Of The Circular Panel

    Installation Procedure Step 12 Optional: For the installation of the circular panel Making a circular opening on the ceiling For the painting of the panel English...
  • Page 17: Step 13 Connecting The Power And Communication Cables

    Step 13 Connecting the power and Wiring terminals) 1 phase (AC018/024TN4FEC) communication cables Indoor Unit CAUTION Outdoor Unit 1(L) 2(N) CAUTION Cable Cable clamp Indoor power Communication Main power cable cable Wiring terminals) 1 phase (AC036/048TN4FEC) Indoor unit Outdoor unit 1(L) 2(N) Communication Indoor power...
  • Page 18: Step 14 Optional: Extending The Power Cable

    Installation Procedure NOTE Cable insert hole CAUTION Step 14 Optional: Extending the power cable Tools Spec Shape Power cable Communication cable Indoor power supply Power supply Max/Min(V) Indoor power cable Communication cable (Unit: mm) Communication: M3.5 screw AC power: M4 screw English...
  • Page 19 (Unit: mm) Power cable Compression dimension Pre-installed tube for the power cable Method 1 Method 2 Compress it 4 times. Compress it 4 times. CAUTION 5 mm 5 mm Method 2 Method 1 Insulation tape Insulation tape Method 1 Method 2 40 mm 35 mm Method 1...
  • Page 20: Step 15 Setting The Indoor Unit Addresses And The Installation Options

    Installation Procedure Step 15 Setting the indoor unit addresses and the installation options Method 2 Method 1 Insulation tape Insulation tape Common steps for setting the addresses and options Remote control (for 360 cassette only) CAUTION Entering the Setting the mode for setting option values the options...
  • Page 21 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 CAUTION SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 On (SEG1 to SEG12) Off (SEG13 to SEG24) Steps Remote control display Cool English...
  • Page 22 Installation Procedure Steps Remote control display Heat English...
  • Page 23 Steps Remote control display Auto Cool English...
  • Page 24 Installation Procedure Steps Remote control display Heat English...
  • Page 25 Steps Remote control display Remote controls Entering the Setting the [SEG6, SEG8] [SEG9, SEG10] [SEG2, SEG3] [SEG4, SEG5] mode for setting option values the options [SEG16, SEG17] [SEG18, SEG20] [SEG11, SEG12] [SEG14, SEG15] [SEG21, SEG22] [SEG23, SEG24] NOTE English...
  • Page 26 Installation Procedure SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 CAUTION SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 On (SEG1 to SEG12) Off (SEG13 to SEG24) Steps Remote control display Cool English...
  • Page 27 Steps Remote control display English...
  • Page 28 Installation Procedure Steps Remote control display Heat Auto English...
  • Page 29 Steps Remote control display Cool English...
  • Page 30 Installation Procedure Steps Remote control display Heat [SEG2, SEG3] [SEG4, SEG5] [SEG6, SEG8] [SEG9, SEG10] [SEG11, SEG12] [SEG14, SEG15] [SEG16, SEG17] [SEG18, SEG20] [SEG21, SEG22] [SEG23, SEG24] English...
  • Page 31 Setting the indoor unit addresses Option No. for an indoor unit: Common steps for setting the addresses and 0AXXXX-1XXXXX-2XXXXX-3XXXXX options Indoor unit Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 CAUTION English...
  • Page 32 Installation Procedure Setting the installation options in a batch Common steps for setting the addresses and options Option No. for an indoor unit: 02XXXX-1XXXXX-2XXXXX-3XXXXX Indoor unit Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 English...
  • Page 33 Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 Option SEG19 SEG20 SEG21 SEG22 Option SEG23 SEG24 English...
  • Page 34 Installation Procedure Soft Off Hard Off Changing the addresses and options individually Common steps for setting the addresses and options Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 English...
  • Page 35 Emergency Temperature Output (ETO) function CAUTION – – – Setting up the ETO – – – – – – [Master] [Slave] English...
  • Page 36 Installation Procedure ETO operation specifications – – – Enable of ETO Enable of external contact Error port output Main indoor unit Enable of entrance control Enable of external contact Operation when outputting Main Sub indoor unit English...
  • Page 37: Appendix

    Appendix Troubleshooting Indoor unit display indications Condition Ice blue Yellow green Blue English...
  • Page 38: Packing And Unpacking Guide

    Appendix Packing and unpacking guide Indoor unit Cushion-top Packing case Indoor unit Cushion-bottom English...
  • Page 39: Product Specification

    Product specification MODEL AC018TN4FEC AC024TN4FEC CLIMATE CLASS COOLING RATED CAPACITY HEATING (H1) RATED VOLTAGE & FREQUENCY COOLING RATED CURRENT HEATING (H1) COOLING RATED POWER INPUT HEATING (H1) COOLING EER / COP HEATING (H1) REFRIGERANT kg, TYPE for 2,000 Hr ANNUAL ENERGY CONSUMPTION for 2,700 Hr COOLING...
  • Page 40 Appendix MODEL AC036TN4FEC AC048TN4FEC CLIMATE CLASS COOLING RATED CAPACITY HEATING (H1) RATED VOLTAGE & FREQUENCY COOLING RATED CURRENT HEATING (H1) COOLING RATED POWER INPUT HEATING (H1) COOLING EER / COP HEATING (H1) REFRIGERANT kg, TYPE for 2,000 Hr ANNUAL ENERGY CONSUMPTION for 2,700 Hr COOLING...
  • Page 41 Memo English...

Table of Contents