Page 1
INSTRUCTION MANUAL FOR WATCH CALIBRE V192 THIS PRODUCT CONTAINS A BUTTON BATTERY If swallowed or placed inside any part of the body, the battery can cause severe or fatal injuries within 2 hours or less. Button batteries are hazardous whether new or used. Keep batteries out of reach of children.
You are now the proud owner of a SEIKO Analogue Quartz Solar Cal. V192/V194. For the best results, please read the instructions in this booklet carefully before using the watch. Please keep this manual handy for ready reference. CONTENTS Wir gratulieren Ihnen zum Kauf der SEIKO Analog-Quarzuhr mit Solarzelle Kal. V192/V194. Lesen Sie...
BEFORE USE DISPLAY & BUTTONS It may be necessary to perform the initial settings such as hand position adjustment and l Cal. V194 time/calendar setting. Set the watch according to the procedure “TIME SETTING AND Big date calendar Hour hand HAND POSITION ADJUSTMENT”...
Page 5
l Cal. V192 ◆ The POWER RESERVE DISPLAY mode is used to display the power reserve status, main time, and date. ◆ The STOPWATCH mode is used for elapsed time measurement functions. STOPWATCH 1/5-second hand Hour hand Minute hand • Some models may have a screw lock type crown.
SCREW LOCK TYPE CROWN HOW TO CHANGE THE DISPLAY MODE ◆ Some models may have a screw-lock mechanism that can securely lock ◆ The display mode alternates between the POWER RESERVE DISPLAY mode the crown by screw when not in use. and the STOPWATCH mode by following the procedure below.
TIME SETTING AND HAND POSITION ADJUSTMENT • When the display mode is switched, the function of the hands will change accordingly. • Before switching the display mode from the STOPWATCH mode to the POWER RESERVE ◆ This watch is designed so that the following adjustments are made with the DISPLAY mode, make sure that the stopwatch has been reset.
Page 8
How to check the position of the hands Check that the second hand moves at normal one-second intervals when the crown ◆ Check that the position of each hand is is at the normal position. When the watch is stopped or the second hand is moving at the preliminary position by referring at 2-second intervals, charge the watch by exposing it to light.
Page 9
How to adjust the position of the hands The position of each hand can be readjusted in the following order by pressing button A. Press to set the power reser ve indicator STOPWATCH 1/5-second Power reserve indicator pointing at the low level. hand The hand moves quickly if but ton B is continuously...
SETTING THE DATE • This operation can be performed both in l Before setting the date, be sure to set the main time. the POWER RESERVE DISPLAY mode l Cal. V194 and STOPWATCH mode. Big date calendar CROWN Pull out to the first click. Turn to set the main dial time.
HOW TO USE THE STOPWATCH <How to reset the stopwatch> l The stopwatch can measure up to 60 minutes in 1/5-second increments. While the STOPWATCH hands are moving When the measurement reaches 60 minutes, the stopwatch automatically 1. Press Button A to stop the stopwatch. stops.
HOW TO CHARGE AND START THE WATCH Standard measurement ◆ When you start the watch or when the energy in the rechargeable battery is reduced to an extremely low level, charge it sufficiently by exposing the START STOP RESET watch to light. Accumulated elapsed time measurement Expose the watch to sunlight or strong artificial light.
POWER RESERVE INDICATOR CAUTION The power reserve indicator can be used to check the power reserve amount (continuous operating time). Caution for charging When charging the watch, do not place it too close to a photoflash lHow to check the power reserve amount light, spotlight, incandescent light or other light sources as the The power reserve indicator displays the remaining power reserve amount in watch temperature will become extremely high, causing damage to...
GUIDELINE OF CHARGING TIME/ACCURACY ◆ The watch operates while c h a r g i n g e l e c t r i c i t y b y V192/V194 converting light received on Environment/Lightsource (lux) the dial to electrical energy. Display by the power B (hours) C (hours) It cannot properly operate...
ENERGY DEPLETION FOREWARNING FUNCTION NOTE ON POWER SUPPLY When the energy stored in the rechargeable battery is reduced to an The battery used in this watch is a rechargeable battery, which is different extremely low level, the second hand starts moving at 2-second intervals from ordinary silver oxide batteries.
IMPROPER FUNCTION ROTATING BEZEL (for models with rotating bezel) When an abnormal display appears, follow the procedures below to reset the The rotating bezel can show up to 60 minutes of elapsed time. built-in IC. The watch will resume its normal operation. Turn the rotating bezel to align its "...
TACHYMETER To measure the hourly rate of operation (for models with tachymeter scale on the dial) Ex. 1 Use the stopwatch to measure To measure the hourly average speed of a vehicle STOPWATCH 1/5- the time required to complete 1 second hand: job.
TELEMETER HOW TO USE THE TELEMETER (for models with telemeter scale on the dial) Before beginning, check that the stopwatch has been reset. l The telemeter can provide a rough indication of the distance to the source of light and sound. START l The telemeter indicates the distance from your location to an object that emits (Flash of light)
TROUBLESHOOTING Solutions Troubles Possible causes If you often encounter this problem even though you wear the watch everyday, the The watch stops operating. The energy has been depleted. watch may not be exposed to sufficient light while you wear it. For example, the The small second hand moves at watch may be covered by the cuff of clothing.
Page 20
Troubles Possible causes Solutions The STOPWATCH hands do not Affected by external sources, or because the Adjust the STOPWATCH hands to the 0 position by following the instructions in return to the 0 position when the internal IC had been reset, the stopwatch hand “TIME SETTING AND HAND POSITION ADJUSTMENT.”...
SPECIFICATIONS 1 Frequency of crystal oscillator ..32,768 Hz (Hz = Hertz … Cycles per second) 2 Loss/gain (monthly rate) ....±15 seconds at normal temperature range (5 °C to 35 °C/41 °F to 95 °F) 3 Operational temperature range ..–10 °C to 60 °C/14 °F to 140 °F 4 Driving system ........
Need help?
Do you have a question about the Prospex SSC813P and is the answer not in the manual?
Questions and answers