Summary of Contents for tempmate S2

  • Page 2: Table Of Contents

    13. Contact information ..................................16 1. Introduction 2. Intended use The tempmate.®-S2 is designed to be mounted on a The tempmate.®-S2 is designed to be mounted on broadcast or stationary and measure relevant para- shipments or stationary and to record relevant parame- meters such as temperature and optionally relative ters as mentioned in the datasheet.
  • Page 3: Tempmate.®-S2 Models

    3. tempmate.®-S2 models Single-use Temperature Rel. humidity V1.0-11/2022-EN · Technical Changes and Errors excepted...
  • Page 4: Device Description

    empower your supply chain. 4. Device description 5. Display indicators Press the Start button repeatedly to call up the individual pages on the device display. Start/Stop Button Not started Number Average value measured values LED Indicator Sensor rel. Humidity Started* Highest measured value Start/Stop Button LED Indicator Stopped Lowest Time & Date measured value * If the start delay is set, this symbol flashes after a successful start until the time limit has elapsed.
  • Page 5: Quick Start Guide

    empower your supply chain. 6. Quick Start Guide RECORD STATUS Rec. 3 sec. Stop Rec. Rec. Stop Mark Stop Mark Rec. 3 sec. Stop Rec. Rec. Stop Mark Stop Mark V1.0-11/2022-EN · Technical Changes and Errors excepted...
  • Page 6: Operation And Use

    Press the blue button twice in succession to set a mark. A successfully set marker is indicated by the word „MARK“ and the number of markers set so far Download the free tempbase 2 software. – https://www.tempmate.com/de/download/ in your display. Install the tempbase 2 software on your PC. Important: Up to 10 marks can be set per operation.
  • Page 7: Readout With Tempbase Software

    empower your supply chain. The logger will automatically open as an external drive on your PC. This process may take a few Select the desired file format (PDF/XLS/IME) for export and the file location and confirm the download. minutes depending on the amount of data. Open the drive and copy the PDF and CSV report stored to a local folder. Important: A report is automatically generated as PDF and/or CSV when the device is stopped. The device can still be read out during a running measurement and an intermediate report can be downloaded. Readout with tempbase 2 software (optional) Remove the cap and connect the logger to your PC. Open the tempbase 2 software and select the „Export/Import“ button (3). 8. Important notes The configuration of your device cannot be changed during recording. If you connect the device to the PC without a manual stop, a temporary stop of the recording is triggered. You can now download an interim report. After disconnecting the device from your PC, the recording will continue automatically. Always dispose of devices according to your country‘s regulations. Do not place the device in corrosive liquids and do not expose it to direct heat. V1.0-11/2022-EN · Technical Changes and Errors excepted...
  • Page 8: Main Technical Specifications Tempmate.®-S2 T

    Main Technical Specifications tempmate.®-S2 Main Technical Specifications tempmate.®-S2 Recording Options Single-Use Recording Options Single-Use Dimension [mm] 93 x 47 x 8 mm Dimension [mm] 93 x 47 x 8 mm Weight [g] Weight [g] Casing Ecofriendly Hardcase Casing Ecofriendly Hardcase Battery CR2450 lithium metal button cell battery Battery...
  • Page 9: Contact Information

    Contact information Do you have any questions? Please contact us - our experienced team will be happy to support you. sales@tempmate.com +49 7131 6354 0 V1.0-11/2022-EN · Technical Changes and Errors excepted...
  • Page 10 Wannenäckerstr. 41 74078 Heilbronn, Germany Tel. +49-7131-6354-0 sales@tempmate.com www.tempmate.com...