EXPLANATION OF COMPONENTS
METHOD OF USING MAINTENANCE MODE
To switch from the operation mode to the maintenance mode,
turn the buzzer switch to the
least 2.5 seconds. The screen will switch to the maintenance
mode.
On the first screen, the oil and filter maintenance mode is dis-
played.
EXPLANATION OF MODES AND OPERATION
The maintenance mode has the following 4 sub modes.
Sub mode
Oil/filter maintenance mode
PM clinic auxiliary mode
Fault code display mode
Adjustment mode
Use information switch (1) and buzzer cancel switch (2) to
operate each mode.
3-24
position and hold it there for at
Function
Oil or filter replacement time is dis-
played
Engine speed or hydraulic circuit
pressure is displayed
Fault codes for electronic control
related parts are displayed
Adjusts monitor brightness, etc.
Reference items
METHOD OF USING OIL AND FILTER
MAINTENANCE MODE (3-26)
METHOD OF USING PM CLINIC AUXIL-
IARY MODE (3-28)
METHOD OF USING FAULT CODE DIS-
PLAY MODE (3-29)
METHOD OF USING USER ADJUST
MODE (3-30)
OPERATION
3