Summary of Contents for Oregon Scientific Starck PSM06A
Page 1
Full Weather Station with Radio-Controlled Clock, Projection and AM/FM Radio (Model #: PS-M06 / PS-M06U) User Manual PS M06 English Cover 7/1/03, 1:52 AM...
ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio-Controlled Projection Clock and AM/FM Radio (PS-M06 / PS-M06U). This powerful device bundles time keeping, alarm, indoor and wireless outdoor temperature and humidity monitoring, weather...
BACK VIEW FOCUS SELECT RADIO STATION TUNING SLEEP ROTATION DOWN ALARM CHANNEL PS M06 English R19 BUTTON DESCRIPTIONS Select - switch modes / change settings ( Focus - focus projector ( Up - increase setting / activate auto-synch Rotation - rotate projector ( Alarm -activate / deactivate alarm ( Channel - switch remote unit ( Radio - turn radio or radio alarm on/off...
Page 7
BOTTOM AND SIDE VIEW PS M06 English R19 DESCRIPTIONS Battery compartment Backlight switch Reset button ( Light sensitivity knob ( Headphone jack ( DC power input jack Antenna NOTE AC power adapter not shown. DC 7.5V 8, 21) 7/16/03, 1:05 PM...
GETTING STARTED BATTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries. Use a small Phillips screwdriver to remove the remote unit compartment lid.
SWITCH BETWEEN MODES Press SELECT. The selected mode will flash. The display will stop flashing if no key is pressed within 5 seconds. CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options.
• Position the unit so that it faces the main (indoor) unit. Minimize obstructions such as doors, walls, and furniture. You may need to experiment with various locations to get the best reception. CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-M06) Rugby, England (PS-M06U).
TO DISABLE OR ENABLE AUTO- SYNCHRONIZATION In Clock mode, press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. To enable auto-reception, press UP for 2 seconds. SET OR CHANGE THE CLOCK Press SELECT to switch to the Clock Mode.
UP or DOWN to change the setting. Press SELECT to confirm. If you choose , also select the melody (1 - 7) and volume level (Lo or Hi). If you choose , use the radio control buttons to select the AM/FM band, radio station and volume level 18).
Select the year, month, date, and language. Press UP or DOWN to change the setting. Press SELECT to confirm. The language options are (E) English, (F) NOTE French, (D) German, (I) Italian, and (S) Spanish. MOON PHASE Press SELECT until the Calendar Area flashes. Then, press UP or DOWN to change the date and view the corresponding moon phase.
BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed. Trend Description Pressure change (mb/hPa) 1 hr Rising Steady Steady Falling PS M06 English R19 VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes.
WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy. The weather forecast is always displayed. Clear Cloudy Partly Cloudy PS M06 English R19 TEMPERATURE AND HUMIDITY With the press of a button, you can check the current...
CLEAR MIN / MAX MEASUREMENTS While viewing Min/Max records, press and hold UP DOWN for 2 seconds until a beep sounds. This clears the previous measurements from the memory. SELECT REMOTE UNIT CHANNEL While in the Temperature / Humidity Mode, press CHANNEL to switch between CH 1, 2, or 3, or press and hold CHANNEL for 2 seconds to enter Auto scan mode.
COMFORT ZONE The indoor and outdoor comfort zones are shown for the following conditions. Zone Temperature 20 - 25 °C (68 - 77 °F) Comfort PS M06 English R19 TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately.
SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between °C and °F. Press SELECT to confirm. RADIO You can listen to Phase Lock Loop (PLL) digital radio broadcasts with this product. ANTENNA The antenna wire is located on the side of the unit.
STORE STATION TO MEMORY Press STATION for 2 seconds. The assigned number (1 - 8) will show in the Radio Area. SLEEP TIMER Press SLEEP. To change the timer length (0 - 120 minutes in increments of 10) press UP or DOWN.
The Light sensitivity knob is located in the battery compartment. Rotate to adjust. When activated, the continuous backlight will be half as bright as usual. To achieve full brightness, press SNOOZE/LIGHT. LIGHT SENSOR LIGHT ON OFF AUTO RESET PS M06 English R19 PROJECTOR This product has a built-in projector for viewing time and alarm status at night.
FOCUS IMAGE The FOCUS switch is located on the back of the unit. Rotate to adjust. CONTINUOUS PROJECTION The AC power adapter must be plugged in to use this feature ( Press and hold SNOOZE/LIGHT for 2 seconds when the projection is on. When activated, the time and alarm status will project continuously.
WARNINGS This product is designed to give you years of service if handled properly. Observe the following guidelines: • Never immerse the unit in water. This can cause electrical shock and damage the unit. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity.
TROUBLESHOOTING Check here before contacting our customer service department. Symptom Remedy Problem Temp Shows “LLL” or Temperature is out-of- “HHH” range. Calendar Strange date / Change language month Projector No continuous Plug in AC power projection adapter Backlight No continuous Plug in AC power backlight adapter.
Page 25
Symptom Remedy Problem Clock Cannot Remove batteries. auto-synchronize Press reset. All memory items will return to default. Replace batteries. Place clock near window / away from electrical devices, and wait 10 - 20 minutes. If it still fails, you may be too far from a signal.
SPECIFICATIONS Main unit dimensions L x W x H 129 x 43 x 133.3 mm (5.1 x 1.7 x 5.3 inches) Weight 536 grams with batteries Remote unit dimensions L x W x H 75 x 35 x 78.3 mm (3 x 1.4 x 3.1 inches) Weight 136 grams with battery...
Page 27
Barometer Unit mb/hPa or inHg Range 500 to 1050 mb (14.77 to 31.01 inHg) Resolution 1 mb (0.03 inHg) Altitude -100 to 2500 meters (-328 to 8202 feet) Display Rainy, cloudy, partly cloudy, sunny Memory 24 hour Trend 1mb change in 1 hour or 3mb change in 6 hours Remote unit RF frequency...
Page 28
Radio Type Digital tuning PLL (Phase Lock Loop) stereo Band 531 to 1602 kHz (AM) 87.5 to 108.0 MHz (FM) Stations 8 AM / 8 FM Volume 8 levels (0 - 7) Sleep timer 120 minutes in increments of 10 Headphones Stereo-sound (not supplied) Antenna...
ADDITIONAL RESOURCES Visit our website (www.oregonscientific.com) to learn more about your new product and other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach us.